175
SJ6826RT, SJ6832RT
213560ABA
Load Sensing System
Section 5 – Procedures
Code F43: High Pressure
This message indicates that the pressure transducer output (P4-2) is too high (4.5 V or more) at the beginning of
calibration.
▪
Check DIAGNOSTICS / SENSORS to read output.
Code F44: Low Pressure
This message indicates that the pressure transducer output (P4-2) is too low (0.5 V or less) at a measurement
point.
▪
Check DIAGNOSTICS / SENSORS to read output.
Code F45: High Pressure
This message indicates that the pressure transducer output (P4-2) is too high (4.5 V or more) at a measurement
point.
▪
Check DIAGNOSTICS / SENSORS to read output.
Code F46: Check Elev
This message indicates that the elevation switch opened more than once during calibration lifting.
Code F47: Check Elev
This message indicates that the elevation switch closed more than once during calibration lower.
Code F48: Bad Pressure
This message indicates that the pressure transducer output (P4-2) is out of range at the beginning of calibration.
▪
Check DIAGNOSTICS / SENSORS to read output.
Code F52: Too Few
This message indicates that not enough measurements were recorded during calibration lifting or lowering.
Code F98: Out of Range
This message indicates that the fine tune calibration is unacceptable.
This is probably due to a faulty transducer or faulty/open holding valve(s)/ emergency lowering valve.
During calibration the following information messages may appear:
Platform Down?
This message is prompting for confirmation that the platform is fully lowered. If necessary the DOWN switch can
be activated to lower the platform. Press ENTER to confirm when the platform is fully lowered.
Platform Empty?
This message is prompting for confirmation that the platform is completely empty. Press ENTER to confirm if the
platform is empty.