![Skyjack SJ 6826RT Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/skyjack/sj-6826rt/sj-6826rt_service-manual_1290452121.webp)
125
SJ6826RT, SJ6832RT
213560ABA
Hydraulic Systems
Section 4 – Troubleshooting Information
4.3-14 Hydraulic Generator Inoperative
1.
Stuck or defective Hydr.Generator Valve 2H-86D.
Check valve. Repair or replace if defective.
2.
Incorrectly adjusted or defective Flow Control Valve
FC1.
Adjust valve. Replace if defective.
3.
Stuck or defective Large Pump Dump Valve 2H-17B.
Check valve. Repair or replace if defective.
4.
Defective Hydr.Generator Motor GM1.
Check motor. Repair or replace if defective.
4.3-15 All Outriggers Inoperative
1.
Stuck or defective Outrigger Holding Valve 2H-17C.
Check valve. Repair or replace if defective.
4.3-16 Outriggers Inoperative
Left Front
1.
Stuck or defective Left Front Up Outrigger Valve 4H-71
(Retract).
Clean valve. Replace if defective.
2.
Stuck or defective Left Front Down Outrigger Valve
4H-75 (Extend).
Clean valve. Replace if defective.
3.
Stuck or defective Check Valve CV7.
Check valve. Replace if defective.
4.
Fluid is bypassing Outrigger Cylinder C9 internally.
Check cylinder and repack if necessary.
Replace if defective.
Right Front
5.
Stuck or defective Right Front Up Outrigger Valve 4H-
72 (Retract).
Clean valve. Replace if defective.
6.
Stuck or defective Right Front Down Outrigger Valve
4H-76 (Extend).
Clean valve. Replace if defective.
7.
Stuck or defective Check Valve CV8.
Check valve. Replace if defective.
8.
Fluid is bypassing Outrigger Cylinder C10 internally.
Check cylinder and repack if necessary.
Replace if defective.