![Skyjack SJ 6826RT Скачать руководство пользователя страница 149](http://html.mh-extra.com/html/skyjack/sj-6826rt/sj-6826rt_service-manual_1290452149.webp)
153
SJ6826RT, SJ6832RT
213560ABA
Outriggers
Section 5 – Procedures
5.4-2
Outrigger Control Module (OCM1) Pin Reference Table (GP-106)
LED
GP106 CONTROL MODULE
PLUG
PIN
#
WIRE #
AND
COLOUR
WIRE FUNCTION
Calibration Connection (RS232)
P1
1
B+
Not connected –used for hand held calibration device connection
P1
2
Rx
P1
3
Tx
P1
4
GND (-)
Inputs
P2
1
68A White
12V Input from LS68 Left Rear Outrigger Down limit switch
P2
2
67A Red/White
12V Input from LS67 Right Rear Outrigger Down limit switch
P2
3
66A Blue/White
12V Input from LS66 Right Front Outrigger Down limit switch
P2
4
65A Green/White 12V Input from LS65 Left Front Outrigger Down limit switch
P2
5
70 Green/Black
12V Input from S24 Outrigger Auto Level request signal
P2
6
79 Green
12V Input from S24 Outrigger Auto All-Up request signal
P2
7
70A Red/White
12V Output for Outrigger Light OL1
P2
8
65 Green/Black
12V Input from LS61, LS62, LS63 & LS64 Outriggers limit switch Up signal
** (all switch contacts must be closed to produce in series signal)
P2
9
Not Used
Not Used
P2
10
44 Red
12V Input from 35CR Elevation Tilt Override/High Speed Cutout Relay
P2
11
02 White
GND B- 0V Reference Input from Base Terminal Strip
P2
12
10A Black
12V B+ Input thru Main Power Relay 10BCR From Base Terminal Strip
Outputs
P4
1
78 Black/White
12V Output for Outrigger Left Rear Down signal to 4H-78 Solenoid
P4
2
77 Blue/Black
12V Output for Outrigger Right Rear Down signal to 4H-77 Solenoid
P4
3
76 Red/Black
12V Output for Outrigger Right Front Down signal to 4H-76 Solenoid
P4
4
75 Orange/Black 12V Output for Outrigger Left Front Down signal to 4H-75 Solenoid
P4
5
74 Black
12V Output for Outrigger Left Rear Up signal to 4H-74 Solenoid
P4
6
73 Blue
12V Output for Outrigger Right Rear Up signal to 4H-73 Solenoid
P4
7
72 Red
12V Output for Outrigger Right Front Up signal to 4H-72 Solenoid
P4
8
71 Orange
12V Output for Outrigger Left Front Up signal to 4H-71 Solenoid
P4
9
35C White/Black
12V Output for Outrigger Enable signal from Enable switch S9A or Relay 9CR3
To
order
go
to
Discount-Equipment.com