Load Sensing System
Section 5 – Procedures
32.
Hold the lower switch and keep holding it until the platform is fully lowered.
33.
When the system detects the lower switch closed, the display shows
Calibrate Load: Lower Empty
34.
After a delay, the system stops the platform lowering and takes height and pressure measurements.
The display shows
MEASURING #xx
. When the measurements have been taken, the platform resumes
lowering.
NOTE
The lowerin, .stopping,measuring,lowering
process continues until the platform is fully
lowered
.
35.
When the platform is fully lowered (and height 0% is displayed), release the lower switch.
36.
The display shows briefly
TOTAL DATA: 04
to indicate the number of measurements taken.
37.
The display shows
Calibrate Load: Caldate: mm/dd/yy
.
▪
It is recommended that the current date be entered here to provide easy taking of the data of last
calibration.
▪
The current date must be entered using the
LEFT/RIGHT
and
UP/DOWN
buttons
38.
Press ENTER to complete date entry (the information is stored).
39.
The display shows
Calibrate Load
option.
40.
Press the ESC button to exit the
Calibrate Load
option.Remove the jumper wire and re-connect the black
wire #14 to the coil removed earlier.
41.
Close the hydraulic/electric tray.
NOTE
Continuing partially complete load calibration .
Once a calibration phase has been successfully completed, it is not required to do it again (unless of course a
change to the vehicle such as a replacement sensor requires that calibration be repeated). This is useful if the
calibration procedure is interrupted – the remaining phases can be completed at a later time.
▪
If a calibration phase has been successfully completed, a
REDO
message is displayed:
▪
REDO DYNAMIC: NO
▪
REDO LOADED: NO
▪
REDO EMPTY: NO
▪
If the phase does not need to be repeated, just press
ENTER
to move on.
▪
If the phase does need to be repeated, press
UP
or
DOWN
to change
NO
to
YES
then press
ENTER
.