172
SJ6826RT, SJ6832RT
213560ABA
Section 5 – Procedures
Load Sensing System
5.5-7
LED Error Codes – Code Breakdown Chart (Continued)
LED Flash Code
Description
Action
11
Vehicle Tilted
These are not true faults but an indication that vehicle
movement is prevented. Remove excessive load from
the platform. Lower the platform if close to maximum
height. Move the vehicle to level ground.
12
Vehicle Overloaded
14
Too High – Drive Prevented
15
Too High – Lift Up Prevented
65
Invalid Height – Check Sensor
Check the voltage out of the height transducer, into
P4-3. It should be between 0.4 V and 4.6 V and
should vary as the platform position varies.
78
Testing HWFS
These are not true faults unless they do not clear
the start-up tests should only occur for a short
time.
77
Start Up!
66
Overload Functions Disabled!
These are not true faults – the GP102 has been
configured to suppress overload functionality.
67
Factory Override
Always Off
Idle Timeout Active!
Action a function to clear the idle timeout if it
occurred. Ensure the GP102 is correctly mounted
– incorrect mounting can cause the bad tilt sensor
diagnostic to occur. Otherwise there may be an
internal problem with the GP102.
71
Fault: Bad Tilt Sensor
72
Fault: Bad HWFS
73
Fault: Bad Slave Analogs
74
Fault: Bad Strain Monitors
75
Fault: Bad Slave Micro
76
Fault HWFS Stalled!
To
order
go
to