55
3.3.4
Group “D” Fault Codes
Group “D” fault codes represent faults detected for capacity chart selection.
The following chart details all the available codes in the left column and the actions to take in the right
column.
FAULT
CODE
WRONG
SWING
AREA
WRONG
BOOM
LENGTH
CHART NOT
FOUND
ACTION
000
No Fault Found
NONE
001
X
Check other sensor faults first, Re-select
CRANE CONFIGURATION
002
X
Boom length is out of range for selected
chart. Check crane setup, boom length and
extension.
003
X
X
Check other sensor faults first, Re-select
CRANE CONFIGURATION
004
X
Swing to correct working area to select
chart.
Check swing sensor zero position.
Follow SECTION 3.10.4
005
X
X
Swing to correct working area to select
chart.
Check swing sensor zero position.
Follow SECTION 3.10.4
006
X
X
Check other sensor faults first, Re-select
CRANE CONFIGURATION
007
X
X
X
Check other sensor faults first, Re-select
CRANE CONFIGURATION
SkyAzúl, Equipment Solutions
www.skyazul.com
301-371-6126
Содержание Greer MG514
Страница 1: ...Greer MG514 Retrofit Installation Calibration and Service Manual...
Страница 2: ......
Страница 4: ......
Страница 88: ......
Страница 89: ......