24
2.6.4
Menu 03 - Zero Sensors
This menu allows the user to enter the zero point of the extension sensor.
1. Ensure the boom is completely retracted and at 0°. Verify with a digital level.
2. Press the
Next
or
Prev
button until “03 Zero Sensors” appears in the right of the information
window.
3. Press the
03 Zero Sensor
button to enter the routine.
4. Press the
Zero Extension? = XXX
button.
5. The extension sensor will now show
“Zero
No.2 = 0”
.
6. Press the
Next
button to enter the zero point for the angle sensor. This is done using the digital
level.
7. Press the
Zero No. 3 =X.XX
button.
8.
The angle sensor will now show “Zero No. 3
= 0
”
TEST
SET
TEST
SET
SkyAzúl, Equipment Solutions
www.skyazul.com
301-371-6126