Page 85
EN
PGA 3 enter threshold values, Table 1 from 2
Step
Key
Function
1
Select main menu
Press
function key F1
In the main menu the cursor flashes in the Addr. entry field (Address of
the IPM 12 to be selected).
2
Select actual/setup value menu
Use the
numeric keypad
to enter the address of the IPM 12 pulse
meter ( e.g. Addr. 1).
The actual/setup value menu is jumped to, measuring points 1 to 6.
3
Press
next step function key
The actual/setup value menu is jumped to, measuring points 7 to 12.
4
Select display menu
Press
next step function key
The display menu is jumped to.
5
Select code menu
Press
function key F2
The code menu is jumped to.
6
Enter code number via the
numeric keypad
Press the
ENTER
key
The input menu is jumped to.
7
Select threshold value input menu
Press
function key F3
The threshold value input menu is jumped to.
7. Operating
7.8 Enter threshold values
7.6 Warning threshold in the event of
underlubrication
7.7 Warning threshold in the event of
overlubrication
The underlubrication threshold can be pro-
grammed with the help of the PGA 3 pro-
gramming and display unit or with a laptop.
100 %
value of tolerance
disruption
z.B. 30 %
%
t
100
100 % - 30 %
Calculation Alarm threshold
(%) =
z.B. =
=143 %
100
100%-value of tolerance disruption (%)
.
%
.
%
Underlubrication
Overlubrication alarm threshold
2
3
Содержание IPM 12
Страница 47: ...Seite 47 DE...
Страница 51: ...Seite 51 DE 11 4 COMO Zentralschmiersystem berwachung 11 Anschlussbeispiele Men struktur...
Страница 53: ...Seite 53 DE...
Страница 101: ...Page 101 EN...
Страница 105: ...Page 105 EN 11 4 Overview COMO Lube System Monitoring 11 Connection example menu structure...
Страница 107: ...Page 107 EN...