Page 74
EN
IPM 12 Characteristics
General
Housing material
ABS
Mounting position
any
Ambient temperature 0...+ 70 °C
Weight
0.67 kg
Type of protection
IP64
Connection type:
threaded cable joints
Screw terminal
1.5 mm²
Electrical
Operating voltage
24 V DC
Tolerance
± 15 %
Power (input)
0.15 A
Interface RS232
Transmission rate
9600 baud
Signal excursion
± 9 V
Signal inputs
12 Pulse generator inputs
1)
(minimum pulse
width 20 ms)
PNP initiators (three-wire technology)
As per Namur (two-wire technology)
24 V DC contactor (max. 15 mA)
1) When the input signal for the start mode
and RESET are used the number of available
inputs reduced to 10.
Chain
Adr1
Master
group 1
group 2
grup 3
Adr4
Master
Adr2
Slave
Adr5
Slave
Adr3
Slave
Adr6
Master
PGA 3
F1
S1
S2
1
PGA3
0/0 0/0 0/0 4/2 0/0 6/5
input
in PGA 3
IPM 12-Master unit
IPM-12 Slave unit
6.1.4 Example of group coniguration
In the case of the above example of a PGA 3
devices are classified as masters and slaves
as follows:
1 Input:
master: Addr 6
slave:
Addr. 5
2. Input:
master: Addr 4
slave:
Addr. 2
The lowest device address of the combi-
ned slave devices (Addr. 2 in the above
example) is entered. The software calculates
from that the total number of slave units
between the first slave unit and the mas-
ter unit (above example, 2 slave devices,
Addr. 2 and Addr. 3).
6.1.5 IPM 12 Characteristics
6. Description of components
Содержание IPM 12
Страница 47: ...Seite 47 DE...
Страница 51: ...Seite 51 DE 11 4 COMO Zentralschmiersystem berwachung 11 Anschlussbeispiele Men struktur...
Страница 53: ...Seite 53 DE...
Страница 101: ...Page 101 EN...
Страница 105: ...Page 105 EN 11 4 Overview COMO Lube System Monitoring 11 Connection example menu structure...
Страница 107: ...Page 107 EN...