Page 72
EN
Table 1
Key
Function
RES
et
Resets the actual/setup value
or acknowledges an existing
error message
SERV
ice
IActivate actual/“setup value
(service routine)
SEL
ect
To select measuring points
MEM
ory
o save the actual/setup value
RES
SERV
SEL
MEM
6. Description of components
The operating manual applies to the VARIOLUB
monitoring system that consists of:
IPM 12 pulse meter
PGA 3 programming and display unit
Mobile PGA 3 unit
The VARIOLUB monitoring system is designed
to monitor and evaluate incoming pulses (e.g.
from gear-type flow indicators or progressive
feeders) from circulating-oil systems with a
large number of lubrication points.
Malfunctions can be quickly recognized by
constant comparison of incoming actual values
with previously programmed limit values. A
machine shutdown is thereby avoided.
6.1 IPM 12 pulse meter
green indicator lamp
control panel
connection to mobile
PGA 3 unit
6.1.1 IPM 12 control panel
red indicator lamps (12)
6. Description of components