Page 79
EN
Operating sequence actual/and setup value Comparison
IPM 12
Step
Key
Function
1
Switch over to the service mode
Note!
The setup values are influenced. When the service key is pressed a warning signal is emitted (K2 - see 3.2.3).
Press the
SERV
ice key
The indicator lamp of the first measuring point flashes.
2
Selection of the measuring point
Press the
SELect key
The indicator lamp of the selected measuring point flashes.
Alternatively: select all measuring points
Press the
SEL
ect key (12x) until all the indicator lamps light up
3
Start the setup/actual value comparison
Press the
SERV
ice ke
The set up/actual value comparison is started. When all the odd indicator lamps flash, the setup/actual value comparison is
finished. At the same time, the monitoring of the selected measuring point is suppressed
Alternatively: Reject new setup value
Press the
RES
et key
The service routine is canceled, the newly determined setup value is not saved.
Save actual value as setup value
Press
MEM
ory key and hold
Press
SERV
ice key
The current flow rate is saved as the setup value.
SERV
SEL
SERV
RES
7.1.2 PM 12 actual/and setup value Comparison
7. Operating
Содержание IPM 12
Страница 47: ...Seite 47 DE...
Страница 51: ...Seite 51 DE 11 4 COMO Zentralschmiersystem berwachung 11 Anschlussbeispiele Men struktur...
Страница 53: ...Seite 53 DE...
Страница 101: ...Page 101 EN...
Страница 105: ...Page 105 EN 11 4 Overview COMO Lube System Monitoring 11 Connection example menu structure...
Страница 107: ...Page 107 EN...