Safety hazard caused by wrong spare parts!
Wrong or faulty spare parts can adversely affect safety and
cause damage, malfunctions or total failure.
Therefore:
Use only genuine spare parts from the manufacturer.
•
Spare parts in/on the actuator may only be replaced by SKF.
•
W A R N I N G
The device must be dismantled and sent to the manufacturer. The
address is listed on the
cover back
.
Maintenance plan
Maintenance tasks that are required for optimal and trouble-free
operation are described in the sections below.
If increased wear is detected during regular inspections, shorten
the required maintenance intervals according to the actual indica-
tions of wear.
Linear actuator CAHB-21 maintenance plan
Interval
Maintenance work
To be carried out by
Daily
Check actuator for visible damage
Operator
(
†
see below
Check of visual condition
)
Clean off dust and dirt if necessary
(
†
see below
Cleaning
)
Operator
Monthly
Function check of operating features and safety features (
†
see
below
Inspections and readings
)
Qualified personnel
Check tight fit of the actuator to the hinge head. Tighten if necessary Qualified personnel
Annually
Check connection for tight fit
Professional electrician
As suggested
by processor
Conduct visual inspection of the condition of the permanent
safeguard and the routing of the supply and control cable within the
application. Cable routing elements may not be loose or broken.
Qualified personnel
!
Note!
If the linear actuator is used outside of the environmental
conditions specified earlier in this manual, check such compo-
nents once a month for any changes such as oxidation or
sedimentation.
31