Skanti TRP 9250 Скачать руководство пользователя страница 32

DIFFICULT RECEIVER CONDITIONS

Receiving signals under difficult conditions.

1.

High Sensitivity

Press 

 to increase the Sensitivity by approx. 5dB.

The HiSens annunciator is on when High Sensitivity is
selected.The HiSens should be used if very weak signals
are receiced.

High Sensitivity is switched off by pressing 

 once more.

2.

Antenna Attenuator

Press 

 

 

 to switch on and off

the receiver Antenna Attenuator. The Att annunciator
is on in the display when the Antenna Attenuator is
switched on.
The Antenna attenuator should be used when strong
interferring signals are present at the receiver antenna
input.

Strong interferring signals may distort the wanted signal by overloading the receiver input.

DIFFICULT RECEIVER CONDITIONS

OPERATION

TRP 9250 TECHNICAL MANUAL

2-17

Содержание TRP 9250

Страница 1: ...TRP 9250 250 Watt Radio Transceiver for MF HF SKANTI...

Страница 2: ...ph kqf qom VORM ORM t o q jc L ec q j Skandinavisk Teleindustri SKANTI A S 4 Lautrupvang DK 2750 Ballerup Denmark...

Страница 3: ...d the accompanying documentation is disclaimed The information in this manual is furnished for informational use only is subject to change without notice may contain errors or inaccuracies and represe...

Страница 4: ...tors for External Equipment 3 19 Transceiver Control Unit connector panel 3 19 Transceiver Unit terminal strip panel 3 23 Final installation Check 3 27 Configuration Prom 3 29 Installation related Pro...

Страница 5: ...ff qom VORM qb ekf i j kr i...

Страница 6: ...1 INTRODUCTION Table of Contents General Description 1 3 Basic Versions 1 4 Technical Data 1 6 1 INTRODUCTION Table of Contents INTRODUCTION TRP 9250 TECHNICAL MANUAL 1 1...

Страница 7: ...INTRODUCTION 1 2 TRP 9250 TECHNICAL MANUAL...

Страница 8: ...cted frequency range is also possible with the sweep function Where required by authorities transmitter frequencies can be preprogrammed into a PROM allowing transmission only on these frequencies The...

Страница 9: ...9000 S Transceiver Unit Type TU 9251 S Antenna Tuning Unit Type ATU 9250 TRP 9252 Marine HF SSB Radio System with CW facility 250 Watt P E P Power Amplifier Simplex Semi duplex operation CW operation...

Страница 10: ...peration CW operation Free TX Frequency Selection 1 6 30MHz Free RX Frequency Labelling of Units Transceiver Control Unit Type TCU 9005 S Transceiver Unit Type TU 9255 S Antenna Tuning Unit Type ATU 9...

Страница 11: ...AM single sideband full carrier H3E Reception Double sideband full carrier A3E TLX Reception Transmission Single side band suppressed carrier with modulating sub carrier J2B Sub carrier user programma...

Страница 12: ...f tune and 80 dB above the wanted signal level will cause less than 6 dB reduction in SINAD SSB Image Rejection Greater than 80 dB IF Rejection Greater than 80 dB Spurious Response Rejection Greater t...

Страница 13: ...05 MHz 30 MHz Antenna Requirements 7 18 m wire or whip antenna Antenna Tuning Fully automatic with no presetting Tuning Speed 0 1 0 5 sec Input Impedance Nominal 50 ohm Power Handling Capability 250 W...

Страница 14: ...with float charging IE charac teristic Nominal battery capacity 40 200 Ah Nominel charging time Max 10 hours to 80 capacity receive condi tion 200 Ah battery Float charge voltage Adjustable 26 8 28 8...

Страница 15: ...9000 2 0 1 5 TU 9250 2 4 1 6 ATU 9250 1 0 0 6 DCU 9000 1 1 0 8 PC 9000 0 3 0 3 PRN 9000 0 9 0 5 All distances have been rounded up to the nearest 0 1 metres in order to allow for the maximum deviation...

Страница 16: ...ndwidth 2 19 Transmitter On off 2 20 Transmitter Frequency 2 21 Power Level 2 22 New Medium Power Level 2 23 Tune the ATU 2 24 Simplex Frequency 2 25 Copy Rx Frequency 2 26 Copy Tx Frequency 2 27 Stor...

Страница 17: ...OPERATION 2 OPERATION Table of Contents 2 2 TRP 9250 TECHNICAL MANUAL...

Страница 18: ...TRANSCEIVER CONTROL UNIT KEYS AND ANNUNCIATORS TCU 9000 for versions TRP 9250 S 9251 S and 9253 S TRANSCEIVER CONTROL UNIT KEYS AND ANNUNCIATORS OPERATION TRP 9250 TECHNICAL MANUAL 2 3...

Страница 19: ...CONTROL UNIT KEYS AND ANNUNCIATORS TCU 9002 for versions TRP 9252 S and 9257 S OPERATION TRANSCEIVER CONTROL UNIT KEYS AND ANNUNCIATORS 2 4 TRP 9250 TECHNICAL MANUAL...

Страница 20: ...CONTROL UNIT KEYS AND ANNUNCIATORS TCU 9004 for version TRP 9254 S TRANSCEIVER CONTROL UNIT KEYS AND ANNUNCIATORS OPERATION TRP 9250 TECHNICAL MANUAL 2 5...

Страница 21: ...CONTROL UNIT KEYS AND ANNUNCIATORS TCU 9005 for version TRP 9255 S OPERATION TRANSCEIVER CONTROL UNIT KEYS AND ANNUNCIATORS 2 6 TRP 9250 TECHNICAL MANUAL...

Страница 22: ...the annunciators that a given keying sequence will activate and in this way confirm to you that you have pressed the correct keys Info This symbol is printed next to additional information on the ope...

Страница 23: ...mination level This example starts with no illumination Press to switch to Day Maximum illumination of the display and no illumination of the keyboard Press to switch to Twilight Full illumination of...

Страница 24: ...multaneously to transmit the Two Tone Alarm Signal The Alarm Signal will continue for 45 seconds or untill is pressed 4 Press the handset key and transmit your distress message 5 Release the handset k...

Страница 25: ...Alarm Generator After the ATU tuning the bar graph will display the RF current in the dummy load The symbol is not displayed as no power is applied to the antenna If the transmitter frequency is 2182...

Страница 26: ...lay 2 Enter the receiver frequency that you wish to use e g 4419 4 kHz 3 Press to complete your frequency choise Receiver frequency range 150 kHz to 30 MHz The receiver display will flash if an invali...

Страница 27: ...Speaker is on 2 Press or to adjust the Speaker Level The Speaker annunciator will flash when minimum or maximum speaker level is reached 3 Press to turn the Squelch on and off The Squelch will switch...

Страница 28: ...ress or and key in a Tune Rate in the range 0 01 kHz 99 99 kHz Press to store the rate e g 3 kHz To select the user programmable Tune Rate press or and the display bar is switched off to indicate that...

Страница 29: ...for how long the receiver stays on each receiver frequency may be selected in the range 0 1 second 1 0 second by pressing a numeric key 1 corresponds to the shortest dwell time 0 1 second and 0 corres...

Страница 30: ...of the AGC is needed 3 AGC on Minimum Signal Threshold Press to adjust the Minimum Signal Threshold Signals and noise below the selected Threshold will now be cut off Is usefull when noise keeps comm...

Страница 31: ...AGC off The Sensitivity is now adjusted to the same Signal strength level as when the AGC was on Press to adjust the Sensitivity level Press to switch AGC on again OPERATION AUTOMATIC GAIN CONTROL 2 1...

Страница 32: ...y is switched off by pressing once more 2 Antenna Attenuator Press to switch on and off the receiver Antenna Attenuator The Att annunciator is on in the display when the Antenna Attenuator is switched...

Страница 33: ...signal to the wanted pitch When a BFO key is pressed the beat frequency is shortly shown in the receiver display 2 The display will flash when the minimum or maximum BFO frequency is reached The BFO...

Страница 34: ...Press 2 Press 3 Press The receiver bandwidth is stepped through the available bandwidths 0 3 kHz 2 4 kHz 6 0 kHz 0 3 kHz The actual receiver bandwidth is shown shortly in the receiver display The BW...

Страница 35: ...r on or off 1 Press to turn the transmitter on The TX display will display the selected transmitter frequency 2 Press to turn the transmitter off The TX display will be extinguished OPERATION TRANSMIT...

Страница 36: ...y will flash if an invalid frequency is entered Pressing Enter will return to the previous selected TX frequency Transceiver Unit 9250 TX frequencies pre programmed in the Configuration Prom The corre...

Страница 37: ...to Medium power 2 Press to switch from Medium to Low power 3 Press to switch from Low back to Full power Changing The Transmitter Power Level on versions TRP 9254 and 9255 1 Press for full output pow...

Страница 38: ...ium power will be displayed 100 W 3 Press and the third and last option for Medium power will be displayed 20 W 4 When the required level for Medium power is displayed press to Store the new Medium po...

Страница 39: ...he first time that the handset key is pressed after a new transmit frequency has been selected The conditions might change during a transmission and a new tune up will be needed For example if ice is...

Страница 40: ...transmitter 1 Press to clear both the receiver and the transmitter displays 2 Enter the frequency that you wish to use for both receiving and transmitting e g 2049 kHz 3 Press to complete your frequen...

Страница 41: ...s in the RX and the TX displays 2 Press to copy the receiver frequency Prog and the RX Bar will flash in the display 3 Press to transfer the RX frequency to the transmitter The receiver frequency is n...

Страница 42: ...in the RX and the TX displays 2 Press to copy the transmitter frequency Prog and the RX Bar will flash in the display 3 Press to transfer the TX frequency to the receiver The transmitter frequency is...

Страница 43: ...and mode SSB 2 Press to activate storage of the present set up The Prog and the RX bar will flash 3 Enter the channel number that you wish to use as as storage for the set up e g User Programmable cha...

Страница 44: ...nnel 1221 3 Press The Receiver and the Transmitter frequencies stored in channel 1221 is now selected and will be displayed Recall Numbers 0 99 User Programmable Channels 100 129 GMDSS Distress and Sa...

Страница 45: ...h to TELEX mode Press to switch to R3E mode For versions TRP 9250 9251 9253 and 9257 Press to switch to SSB mode Where enabled press to switch to LSB mode For versions TRP 9254 and 9255 Press to switc...

Страница 46: ...For versions TRP 9255 and 9257 Press to switch to CW mode As standard LSB is only enabled in the Basic version TRP 9254 CW CHANGE MODE OPERATION TRP 9250 TECHNICAL MANUAL 2 31...

Страница 47: ...he Number Of Channels that you wish to scan e g 3 Press to store the Number Of Channels 4 Enter the number of the Trigger Source that you want to use 0 no trigger source 1 squelch 2 signal strength 3...

Страница 48: ...store the Dwell Time 7 Enter the Hold Time which is the period in which the receiver will stay on a frequency if the Trigger Source has detected a signal e g 20 seconds Press to store the Hold Time No...

Страница 49: ...e the channel 10 Enter the third Channel Number to be scanned e g ch 76 from the User Programmable Memory Press to store the channel When the last channel is stored the transceiver will return to norm...

Страница 50: ...small by flashing the number If you store a bigger number of channels than required TRP 9250 will reduce the alocated memory to the actual need after the scan table has been stored and then update th...

Страница 51: ...the next frequency in the Scan Table store a Dwell Time 0 seconds Automatic Stop If you want to stop the scanning when the Trigger Source detects a signal store a Hold Time 99 Scan Table Scan Program...

Страница 52: ...you want to replace Leave a Scan Program You may leave the programming at any time by pressing Remote Scan start stop facility Is available with optional radiotelex modem PCP717tlx or remote control...

Страница 53: ...enter the Scan Program Number e g Scan Program Number 1 Press to complete your choise 3 The Scanning parameters for the selected Scan Program will now be displayed e g Scan Program Number 1 Trigger S...

Страница 54: ...nel Scanning Scanning will start on the next channel in the Scan Table when you press again 3b Press to stop the Channel Scanning Scanning will start on the first channel in the Scan Table when you pr...

Страница 55: ...strength 4 squelch and signal strength e g 2 Press to store the Trigger Source Because signal strength is selected as Trigger Source in this example you must now set the sensitivity level 3 Press or t...

Страница 56: ...ld Time 6 Enter the Step Frequency which is the frequency distance between all frequencies in the sweep e g 3 1 kHz Press to store the Step Frequency 7 Enter the Start Frequency e g 8718 9 kHz Press t...

Страница 57: ...ramming Dwell time The period in which the receiver will listen for a signal on each frequency in the Sweep Band Selectable from 0 4 seconds to 9 9 seconds Hold time The period in which the receiver w...

Страница 58: ...ncy sweep Sweeping will start on the next frequency in the band when you press again 2b Press to stop the frequency sweep Sweeping will start on the first frequency in the band when you press again Th...

Страница 59: ...h to programme e g 9 Press to select the program number 3 Enable Disable the Sleep Program 0 Disable Sleep Program 1 Enable Sleep Program e g 1 Press to store your choise 4 Enter the Channel Number th...

Страница 60: ...ore the Wake Up Time 6 Enter the Fall Asleep Time which is the time of day that you wish this program shall turn off the transceiver e g 15 30 3 30 PM Press to store the Fall Asleep Time When the Fall...

Страница 61: ...Channel The receiver and transmitter will be set to the frequencies of this channel when the Sleep Program turns on the transceiver Wake Up Time Receiver display Transmitter display Fall Asleep Time...

Страница 62: ...ver you may operate the Volume Up Volume Down and Speaker On Off switch If you want to deactivate the Sleep Timer just press any other key than the Volume and Speaker keys If you want to activate the...

Страница 63: ...ying key entries and remote control commands The TRP 9250 will disable the pseudo Sleep and return to normal operation on a remote control command keying and key entry except RX freq mode command volu...

Страница 64: ...10 19 Select special functions 20 74 Installation and service Refer to SERVICE section 98 Security Code 99 Select Configuration Mode Refer to INSTALLATION section No Function 0 Leave System to other...

Страница 65: ...Read Frequency Error 32 View RX EX Signal Path 715 Version 33 View Option Filter 34 View Power Amplifier Version 35 View PA Filter Version 36 View ATU Status 37 View Dummy Load 39 View Optional Inter...

Страница 66: ...g the Volume Up and Volume Down keys Likewise the Side Tone level can be adjusted between 0 and 64 to suit the individual operator The actual Side Tone frequency is displayed in the receiver display a...

Страница 67: ...the receiver input reception quality can be improved by switching on the RF Attenuator Att annunciator is switched on when the RF Attenuator is on Float Antenna When the optional Dummy Load is install...

Страница 68: ...he received signal may deteriorate due to high frequency noise The Intelligibility may be greately improved by switching Treble Cut on during these conditions The Treble Cut may be selected individual...

Страница 69: ...er The Receiver Display shows the current Security Code Key in the wanted Security Code and store it Security Code STO The Security Code is now stored in the currently used CU and must be entered ever...

Страница 70: ...necessary to have direct line of sight between the antennas as it is in the case of VHF radiotelephones Under normal conditions the range of communication can be expected to be up to 800 km at 1 6 MHz...

Страница 71: ...ght will be lower At the same time the radiation will however increase the attenuation of the radio waves The highest frequency that can be used to communication on a certain distance is called the Ma...

Страница 72: ...tion of a Function 3 49 withParameters Directly Executable Functions 3 50 Disable or Enable Keyboard keys 3 50 TRP9250 TRP9251 TRP9253 3 51 with standard Control Unit TRP9254 with standard Control Uni...

Страница 73: ...INSTALLATION 3 INSTALLATION Table of contents 3 2 TRP 9250 TECHNICAL MANUAL...

Страница 74: ...Transceiver Control Units may be connected to the Transceiver Unit using the build in local area network ScanBus The Transceiver Control Units must be chain connected and the maximum distance from th...

Страница 75: ...allation examples and recommended cable specification including the DSC option Cable type 2 x 5 screened multiwire ScanBus termination jumper INSTALLATION MOUNTING THE UNITS 3 4 TRP 9250 TECHNICAL MAN...

Страница 76: ...s also shown in fig s 2 and 3 If the mounting surface is not sufficiently plane then apply washers between the Transceiver Control Unit and the surface 1 Space for handset access min 150 2 Space for c...

Страница 77: ...Transceiver Control Unit from either side The control panel is turned 180 degrees relative to the bottom part to enable cable entry from the opposite side The viewing angle of the LCD display can be...

Страница 78: ...mensions mounting possibilities and the minimum distances to other objects ensuring good cooling as well as a drilling plan 1 Space for airflow min 200 2 Space for cable and airflow min 25 3 Space for...

Страница 79: ...min 1000 Dimensions are in mm Tolerance 1 mm Weight without optional AC power supply 19 5 Kg Weight with optional AC power supply 21 Kg Centre of gravity Doc 4 0 34088 fig 8 Desktop mounting INSTALLA...

Страница 80: ...re cable for interconnection The unit should be installed near the antenna feed point Fig 14 shows mounting details 1 Space to nearest overhang min 50 2 Space for service access min 500 3 Space for ca...

Страница 81: ...al fuses 7 m 2 x 10 mm2 40 A 11 m 2 x 16 mm2 50 A 17 m 2 x 25 mm2 63 A AC DC SUPPLY This section applies if the optional built in AC Power Supply Assembly P 9250 is installed Before connecting the AC...

Страница 82: ...connected to the Battery terminals located to the right of the Connection Board Cable screen is connected to the chassis by means of the cable clamp on the main chassis below the terminals The earth c...

Страница 83: ...open charger on when connected to DC 4 5 6 AC Alarm O AC Alarm C AC Alarm Galvanically isolated AC alarm output Relay contacts max 0 5 A 32 V Alarm condition AC supply missing terminals 5 and 6 are cl...

Страница 84: ...ttery tempera ture compensation Jumper must be moved to TS1 ON when used TS2 2 way terminal strip Temperature Sensor input for high voltage alarm Terminal Designation Description 1 2 TS TS Temperature...

Страница 85: ...pass through a deck two or three 1 2 or M12 bolts should be used for this feed through On wooden ships having a superstructure of metal this superstructure should also be effectively connected to the...

Страница 86: ...1 6 to 30 MHz to wire and or whip antennas of 7 to 18 metres total length If possible long antenna should be installed to avoid reduction of the radiated power in the lower frequency bands Short ante...

Страница 87: ...n Remarks 1 HOOK ON Low when handset is placed in the holder 2 HANDSET KEY Low when handset key is pressed 3 12V 4 MIC 0 1 6Vpp Adjustable 8dB 5 EARPIECE Max 2 1Vpp 6 GND plastic cover cable 1 3 5 2 4...

Страница 88: ...GND 1 1 Supply On Common supply on signal for all xCUs on the ScanBus Active when connected to ground 2 2 Data Data communication between units CAN Net Baud rate 76 8 kb s Spec ISO DIS 11898 3 3 Data...

Страница 89: ...P 9250 may be operated without the ATU 9250 Just connect the 50 ohms antenna system to the coaxial socket marked TX RX at the Transceiver Unit Important In installations with long earth straps to the...

Страница 90: ...lastic cover over the shield and fix the two jack screws into the plastic cover Remote Control Equipment connector 9 way D sub male Pin Designation Description 1 DCD Input Data Carrier Detected or Sca...

Страница 91: ...e input Accepts 15 dBm to 10 dBm 6 Line In C 2 Line In 3 Line Out Balanced 600 Ohm 0 dBm line ouput Adjustable from 15 dBm to 10 dBm 8 Line Out C 4 Line Out 5 Key Galvanic isolated external key input...

Страница 92: ...8 ohms 4 ohms speaker may be connected 2 SPK Headphone for CW operation Headphone Stereo jack female Pin Designation Description 1 H phone Output Hot left and right headphone drive signal 2 H phone 3...

Страница 93: ...ion Morse Key Mono jack female Pin Designation Description 1 Morse Key Input Pulled up to 12v Activated when connected to system ground 2 GND 1 2 INSTALLATION CONNECTORS FOR EXTERNAL EQUIPMENT 3 22 TR...

Страница 94: ...utput Transmit Data 2 PC RX Galvanically isolated input Receive Data 3 PC DTR Galvanically isolated input Data Terminal Ready 4 PC GND Galvanically isolated ground return The interface is opto isolate...

Страница 95: ...ated Accepts 15 dBm to 10 dBm 2 Line In C 3 Line In 4 Line Out Balanced 600 Ohm 0 dBm AF line ouput with centre tap Galvanically isolated Adjustable from 15 dBm to 10 dBm 5 Line Out C 6 Line Out 7 Ext...

Страница 96: ...ircuit is isolated from earth The circuit operates with a minimum differential input voltage of 2 volts The maximum voltage is 15 volts compatible with RS 232 levels Interconnection between devices ma...

Страница 97: ...rd Open collector RS 410N Max 50 mA 32 V 6 Alarm 2 Telex Alarm Output Connects to GND when alarm is on Open collector RS 410N Max 50 mA 32 V 7 24V Output Max 200 mA Internally protected 8 RX Mute TX I...

Страница 98: ...operation a receiver crystal filter must be installed in position Option Filter on PCB RX EX Signal Path 715 in the Transceiver Unit The centre frequency of the filter must be 455kHz and the bandwidt...

Страница 99: ...INSTALLATION 3 28 TRP 9250 TECHNICAL MANUAL...

Страница 100: ...area reserved for GMDSS Distress and Safety Frequencies and other safety frequencies The frequencies and their corresponding mode can be recalled with short numbers from 100 to 199 which are successiv...

Страница 101: ...BFF 7168 1C00 8191 1FFF Customer Specified Frequencies TX Band Limits Versions 9500 01 02 System Configuration Parameters Limiter Byte 255d FFh Not usable Limiter Byte 255d FFh ITU Channels SSB ITU DS...

Страница 102: ...and TX bits indicates receiver and transmitter frequency respectively S F bit indicates a Single Frequency RX or TX which may be recalled with a short number Examples D7 D6 D5 RX TX S F 1 0 0 Receive...

Страница 103: ...D1 D0 Addr n RX TX ITU 0 Modulation Start Channel n 1 BCD X 1000 BCD X 100 n 2 BCD X 10 BCD X 1 Number Of Channels n 3 BCD X 1000 BCD X 100 n 4 BCD X 10 BCD X 1 Start Frequency n 5 BCD X 10MHz BCD X 1...

Страница 104: ...AM 4 CW 5 TLX Telex DSC 6 Reserved for future use 7 SSB R3E 8 Reserved for future use 9 Reserved for future use A Reserved for future use B Reserved for future use C Reserved for future use D Reserved...

Страница 105: ...the specified band and transmission outside the band is inhibited The first 4 bytes specifies the lower legal frequency limit and the next 4 bytes specifies the upper legal frequency limit Several ban...

Страница 106: ...lex 114 16420 0 J3E Distress Safety SSB Simplex 115 16695 0 NBDP Distress Safety TLX Simplex 116 16804 5 DSC Distress Safety TLX Simplex 117 5680 0 J3E Coordinated SAR SSB RX freq 118 490 0 NBDP Meteo...

Страница 107: ...P 9250 Subsequent selection of other modes except R3E will disable the transmitter Inter ship SSB Simplex frequencies in the Maritime Mobile Bands between 4 and 27 5MHz Successive channel numbers are...

Страница 108: ...encies May be recalled directly by entering channel number Mode will automatically be set to SSB TRP 9250 Subsequent selection of other modes except R3E will disable the transmitter Extra frequencies...

Страница 109: ...equencies for TRP 9250 Ship station paired NBDP frequencies in the Maritime Mobile Bands between 4 and 27 5MHz ITU Radio Regulations Apendix 32 Paired Telex Frequencies 4 MHz Band Ch 1 19 6 MHz Band C...

Страница 110: ...6MHz Band Ch 1 23 8MHz Band Ch 1 36 12MHz Band Ch 1 34 16MHz Band Ch 1 39 18 19MHz Band Ch 1 11 22MHz Band Ch 1 45 25 26MHz Band Ch 1 31 229 TX frequencies For verification of TX frequency only TX fre...

Страница 111: ...h BCD X 10MHz BCD X 1MHz 7595d 1DABh BCD X 100kHz BCD X 10kHz 7596d 1DACh BCD X 1kHz BCD X 100Hz 7597d 1DADh Always 0 TX Modulation TX frequency 7598d 1DAEh BCD X 10MHz BCD X 1MHz 7599d 1DAFh BCD X 10...

Страница 112: ...le HST mode All other data are defaulted to 1d 01h Enable SSB mode 7606d 1DB6h 0d 00h Disable SSB mode 1d 01h Enable SSB mode All other data are defaulted to 1d 01h Enable LSB mode 7607d 1DB7h 0d 00h...

Страница 113: ...AM mode 7613d 1DBDh 0d 00h Disable RX in AM mode 1d 01h Enable RX in AM mode All other data are defaulted to 1d 01h Enable TX in AM mode 7614d 1DBEh 0d 00h Disable TX in AM mode 1d 01h Enable TX on 21...

Страница 114: ...on PROM frequencies only 1d 01h Free TX frequency All other data are defaulted to 1d 01h Single sideband 7618d 1DC2h mode display 0d 00h Display upper sideband as USB 1d 01h Display upper sideband as...

Страница 115: ...25d 19h 25d 19h 7602d 1DB2h 1d 01h 1d 01h 1d 01h 1d 01h 1d 01h 1d 01h 7603d 1DB3h 0d 00h 1d 01h 3d 03h 4d 04h 5d 05h 7d 07h 7604d 1DB4h 0d 00h 0d 00h 0d 00h 0d 00h 0d 00h 0d 00h 7605d 1DB5h 0d 00h 0d...

Страница 116: ...guration the Configuration Mode may be protected with a Password As default the Password is equal to 0 which requires no confirmation when selecting Configuration Mode The Password may be changed by s...

Страница 117: ...is changed only Medium and Low are available Directly Executable Functions Some Functions are directly executable and requires no storing of parameters Press Function No The Function will be executed...

Страница 118: ...e 1 8 SSB key Disable Enable 1 9 AM key Disable Enable 1 10 TLX key Disable Enable 1 11 2182 key Disable Enable 1 12 Alarm Keys Disable Enable 1 13 HiSens key Disable Enable 1 14 SQL key Disable Enabl...

Страница 119: ...Disable Enable 1 10 TLX key Disable Enable 1 13 HiSens key Disable Enable 1 14 SQL key Disable Enable 1 15 Tune keys Disable Enable 1 1 16 Rate keys Disable Enable 1 1 17 AGC On Off AGC limit keys Di...

Страница 120: ...1 13 HiSens key Disable Enable 1 14 SQL key Disable Enable 1 15 Tune keys Disable Enable 1 1 16 Rate keys Disable Enable 1 1 17 AGC On Off AGC limit keys Disable Enable 1 1 18 Sensitivity keys Disabl...

Страница 121: ...Enable 1 10 TLX key Disable Enable 1 11 2182 key Disable Enable 1 12 Alarm Keys Disable Enable 1 13 HiSens key Disable Enable 1 14 SQL key Disable Enable 1 15 Tune keys Disable Enable 1 1 16 Rate key...

Страница 122: ...t engaged with DSC telex or Interface A 718 is installed 0 AF is taken from Line Key input on TU or TCU according to function no 73 1 Handset microphone input 2 Key selected input AF input follows act...

Страница 123: ...er AGC Parameters versus receiver mode No 54 Hang the AGC during transmit 1 The AGC action is disabled during transmit 0 The AGC action continues during transmit Default values Receiver Display RX Mod...

Страница 124: ...Long Hang Time 0 corresponds to Short Hang Time If Hang AGC see No 55 is disabled the AGC Hang Time has no influence Default values Receiver Display RX Mode Parameter SSB AM CW TLX HST Hang Time 1 1 0...

Страница 125: ...to a large AF bandwidth 0 corresponds to the normal AF bandwidth Default value is 0 Default values Receiver Display RX Mode Parameter SSB AM CW TLX HST AF Bandwith 0 1 0 0 1 Split Mode Disable Enable...

Страница 126: ...unction Default value shown below No Function ParameterValue 65 Prog Scan Disable Enable 1 66 Prog Sweep Disable Enable 1 67 Prog Sleep Disable Enable 1 68 Prog Power Level Disable Enable 1 69 Prog ST...

Страница 127: ...ut in the TU Line key socket 1 Enables external key input in the TCU Line key socket Default values Receiver Display TX Mode Parameter SSB AM External key input 1 1 No 74 View change External Line key...

Страница 128: ...quency control Value 0 When TELEX with local frequency control is enabled all control of TRP9250 must be carried out manually When TLX on the keyboard is pressed TRP9250 will enter telex mode and resp...

Страница 129: ...errupted and normal operation of the keyboard is possible To reenter control from the Radio Telex modem and hence allow scanning again press the TLX key TRP 9250 will automatically return to Autotelex...

Страница 130: ...rough 6 programmed More Control Units When TRP9250 includes the optional built in DSC Telex Controller Receiver TRP9250 will react onany controlcommand received regardlessofthePrioritySystemstateandcu...

Страница 131: ...Value Disable 0 Start Stop on positive negative transition 1 Start Stop on negative positive transition 2 Start Stop on positive positive transition 3 Start Stop on negative negative transition 4 If...

Страница 132: ...usy annunciator is flashing in the display of all other TCU s to indicate that the transceiver is in use When control from the currently used TCU no longer is needed it is necessary to press Prog 0 En...

Страница 133: ...re updated according to the Exclusive Access parameter The received signal is led to all TCU s and all internal speakers may locally be switched on off The external speaker may be switched on off acco...

Страница 134: ...and Sleep No 95 When function number 95 is selected all parameters and frequency tables of Scan Sweep and Sleep programmes are deleted and reset to factory setting Reset currently used Transceiver Co...

Страница 135: ...edorchangedbyselecting Function Number 99 Next time Configuration Mode is selected the correct Password must be entered to get access to the mode Passwords from 1 to 9 999 999 may be used When functio...

Страница 136: ...l Signals Note 1 If both Scanbus connections are used remove jumper Note 2 May alternatively be connected to DCU9000 115 230 V AC Optional AC Power Supply Battery Charger 24 DC Supply Input Battery Ch...

Страница 137: ...Alarm In GND NMEA RX NMEA RX Supply On Data Data AF AF GND 24V RX AF RX AF GND 1 2 3 5 6 7 8 9 10 4 X X X X ScanBus 1 2 3 4 5 6 7 8 9 0 GND Supply On Data Data AF AF GND 24V RX AF RX AF X X X X X 1 2...

Страница 138: ...Filters 927 DC Power Supply Interface Board 935 4 5 Connection Board 936 4 6 AC Power Supply Board 958 optional 4 6 Charger Control Board 959 4 6 Interface A 718 option 4 6 Programmable Communication...

Страница 139: ...TECHNICAL DESCRIPTION 4 TECHNICAL DESCRIPTION Table of Contents 4 2 TRP 9250 TECHNICAL MANUAL...

Страница 140: ...crophone signal level can be adjusted here AF Amplifier Board 707 TCU Transceiver Control Board 904 The Transceiver Control Board includes Display Keyboard and a microprocessor The microprocessor perf...

Страница 141: ...on driver ATU interface digital TU bus driver remote interface and drivers for the analog circuits The analog part includes voltage regulators analog interface circuits and analog output drivers The T...

Страница 142: ...Power Amplifier The output of the PA Filters is connected to the input of the ATU via RX TX Relay on the DC power supply Interface Board 935 The selection of low pass filter is controlled by the TU Co...

Страница 143: ...lock has been triggered it is necessary to disconnect the mains for min 7 minutes to allow the primary capacitors to discharge before the SMPS can be switched on again Charger Control Board 959 optio...

Страница 144: ...ere the input signal is mixed with a 1 7325 MHz signal originating from an oven controlled oscillator a narrow band 455 kHz crystal filter IF amplifier and 2 mixer The local oscillator signal for the...

Страница 145: ...he antenna current for display at the control unit To prevent overload of the relays current detectors are incorporated in the Inductor Bank and in Capacitor Bank 2 and information fed back to the tra...

Страница 146: ...DSC TELEX MODEM or DSC TELEX MODEM AND 2187 5 kHz WATCH RECEIVER or DSC TELEX MODEM AND SCANNING WATCH RECEIVER or NONE Protection Attenuator Pre driver Bias Key Circuit 17 8176 MHz 45 70 MHz 44 544 M...

Страница 147: ......

Страница 148: ...TION PROCESSOR I O and Data Com Processor and Memory Demodulators and Modulator Alarms and Timers Audio Control Data Drivers Receivers RX AF TX AF PROGRAMMABLE COMMUNICATION PROCESSOR I O and Data Com...

Страница 149: ......

Страница 150: ......

Страница 151: ...st Replacement of Backup Battery 5 5 Cleaning the Air Filter 5 6 Trouble Shooting 5 7 Power Protection 5 8 Service related Prog key 5 17 operations Self Test 5 25 Self Test Introduction 5 25 Self Test...

Страница 152: ...SERVICE 5 SERVICE Table of contents 5 2 TRP 9250 TECHNICAL MANUAL...

Страница 153: ...hould be checked at least once a year The Master Oscillator determines the exact transmit and receive frequencies of the equipment All oscillators age very slowly with time typically with the highest...

Страница 154: ...is shorter on higher receiver frequencies choose higher frequencies for quick adjustment The displayed frequency error of the equipment will be updated every 4 seconds when frequencies above 16 MHz ar...

Страница 155: ...est quality for replacement to avoid leakage Skanti recommends DURACELL Alkaline 1 5 V MN1500 LR6 Size AA 3 pieces The battery life time depends especially on temperature and working conditions but is...

Страница 156: ...ntly especially under dusty working conditions A dusty Air Filter will block efficient cooling and the transmitter output power is hence reduced to avoid over heating Remove the Front Cover of the Tra...

Страница 157: ...he Transceiver Unit This could be caused by a bad cable connection on the data wire between the 2 units 4 The next step is to open the Transceiver Unit and a Check internal fuses cables and plugs b Ch...

Страница 158: ...otection codes and may be requested at any time by pressing The Receiver Display will show the Protection Code If more than one Protection Code is set successively pressing Enter will show the rest an...

Страница 159: ...tec Possible error source TU ATU coaxial cable open Tune Power High Measurement TU Control Board measures too high power output Tune power 40W Protection made ATU selects feed through setting after TU...

Страница 160: ...de Automatic power regulation inhibited Display Flash Protec Med Low High Measurement TU Control Board measures too high power output Medium or Low Power was too high Protection made Power set as Low...

Страница 161: ...too high Reflected power was detected PA Temp Att 0 and PA Att PA Protect 1 Protection made Output power decreased by 14 dB Display Flash Protec Possible cause TU ATU coaxial cable or antenna Note It...

Страница 162: ...ash Protec Possible cause Fan failure or air filter blocked TX Inhibit Measurement External TX Inhibit input is activated Action made TX key inhibit PA SWR Measurement PA SWR was high Protection made...

Страница 163: ...gh setting Display Flash Protec Possible cause TU ATU coaxial cable shorted Bad SWR Measurement ATU measured SWR 8 during Tune Procedure Protection made ATU selects feed through setting Display Flash...

Страница 164: ...t ATU measured SWR 8 during transmission Display Flash Protec Possible cause Bad antenna impedance on the selected frequency High SWR TX Measurement ATU measured SWR 3 but 8 during transmission Possib...

Страница 165: ...nd the power had to be reduced more than 6 dB Possible cause A bad antenna and a low frequency TU ATU com bad Measurement TU ATU communication isnot operating Protection made Key inhibit Display Flash...

Страница 166: ...SERVICE POWER PROTECTION 5 16 TRP 9250 TECHNICAL MANUAL...

Страница 167: ...special functions Refer to OPERATION section 20 74 Service or installation 98 Security Code Refer to OPERATION section 99 Select Configuration Mode Refer to INSTALLATION section No Function 0 Leave S...

Страница 168: ...Error 32 View RX EX Signal Path 715 Version 33 View Option Filter 34 View Power Amplifier Version 35 View PA Filter Version 36 View ATU Status 37 View Dummy Load 38 View ATU Fan 39 View Optional Inte...

Страница 169: ...If more than one Protection Code is set successively pressing Enter will show all codes and finally make a return to the normal operation If environmental or installational conditions such as too high...

Страница 170: ...and Release number as VV RR Transmitter Display Release date as YY MM DD Pressing Enter will make a return to normal operation View TU Configuration version release customer ID and release date Displ...

Страница 171: ...ssing Enter will make a return to normal operation View Option Filter used for telex DSC or CW reception The Receiver Display shows if an optional filter is installed on RX EX Signal Path 715 0 if no...

Страница 172: ...return to normal operation View Optional Interface Board The PCB number will be displayed in the Receiver Display Switch All Annunciators On in display All annunciators in the display are switched on...

Страница 173: ...tion parameters pre programmed in Configuration PROM By pressing Volume up the address and corresponding data are successively shown in the receiver and transmitter display e g RX a 7593 TX d 0 Pressi...

Страница 174: ...SERVICE SERVICE RELATED PROG KEY OPERATIONS 5 24 TRP 9250 TECHNICAL MANUAL...

Страница 175: ...curred The Manual Mode is used to test the transmitter or for service purposes In this mode the tests are performed one by one Tests may be repeated several times giving a technician the opportunity t...

Страница 176: ...r test will be carried out until an error condition occurs or all tests are finished If an error is detected please refer to descriptions of Error Codes where a possible error source is listed When th...

Страница 177: ...of the test you want to performe and press The selected test number is now performed There are three options to proceed either press to perform the next test or press to perform the same test again If...

Страница 178: ...heck and RXAF check are both checked for silence Error code Possible error source PCB 00 OK 01 AF line tone shape volume 715 Cabling 910 715 02 AF output amplifier 935 937 Cabling 910 935 937 TEST 3 T...

Страница 179: ...02 AF mute 715 Cabling 910 715 TEST 7 Test 7 tests Master Oscillator PCB 712 713 Tests if the MO is oscillating using MO check Error code Possible error source PCB 00 OK 01 Master oscillator 712 713 C...

Страница 180: ...zer PCB 911 1 LO Tests if 1 LO is able to lock in band 0 low border Band 45 52 5 MHz 1 LO 45 00000 MHz 3 LO 456 50 kHz The test is OK if SYNCHECK 1 Error code Possible error source PCB 00 OK 01 Synthe...

Страница 181: ...if 1 LO is able to lock in band 1 high border Band 52 5 60 MHz 1 LO 60 00000 MHz 3 LO 456 50 kHz The test is OK if SYNCHECK 1 Error code Possible error source PCB 00 OK 01 Synthesizer 911 Cabling 910...

Страница 182: ...if 1 LO is able to lock in band 3 low border Band 67 5 75 MHz 1 LO 67 50000 MHz 3 LO 456 50 kHz The test is OK if SYNCHECK 1 Error code Possible error source PCB 00 OK 01 Synthesizer 911 Cabling 910 9...

Страница 183: ...PCB 911 3 LO Tests if the synthesizer is able to lock 3 LO low border Band 67 5 75 MHz 1 LO 70 00000 MHz 3 LO 452 50 kHz The test is OK if SYNCHECK 1 Error code Possible error source PCB 00 OK 01 Syn...

Страница 184: ...ath 715 Cabling 910 715 or 911 715 02 AGC 715 Cabling 910 715 or 911 715 03 RX mute 715 TEST 22 Test 22 performs receiver test on RX EX Signal Path PCB 715 in AM mode and with AM filter By choosing th...

Страница 185: ...11 715 02 AGC 715 Cabling 910 715 or 911 715 99 No optional filter installed 715 TEST 24 Test 24 tests squelch on RX EX Signal Path PCB 715 By choosing the right synthesizer frequency the signal passe...

Страница 186: ...1 Not able to lower MGC 715 Cabling 910 715 or 911 715 02 Not able to rise MGC 715 Cabling 910 715 or 911 715 TEST 26 Test 26 tests Automatic Gain Control Hang facility on RX EX Signal Path PCB 715 Ex...

Страница 187: ...iter is set up to produce 15 MHz SSB signal With tone input RF is detected at RF check Shape key is also checked Band 60 67 5 MHz 1 LO 60 00000 MHz 3 LO 456 00 kHz Error code Possible error source PCB...

Страница 188: ...MHz carrier With input grounded RF is detected at RF check Band 60 67 5 MHz 1 LO 60 00000 MHz 3 LO 455 00 kHz Error code Possible error source PCB 00 OK 01 Exciter signal path 715 Cabling 910 715 or...

Страница 189: ...forward detector 740 940 05 Vreflected detector 740 940 06 0 deg detector 740 940 07 90 deg detector 740 940 08 Temperature sensor 740 940 99 No ATU connected TEST 34 Test 34 tests battery voltage and...

Страница 190: ...ed that the selected test frequency is vacant before the transmitter test is carried out Error code Possible error source PCB 00 OK 01 PA Attenuator Relay 720 Cabling 910 720 10 Tune Power Low Coax 71...

Страница 191: ...ne Power 740 940 RX TX relay PCB 935 937 or coax connectors Coax cables 726 935 937 or TU ATU shorted ATU 42 Bad SWR 740 940 Antenna installation or ATU 46 Bad SWR TX 740 940 Antenna installation or A...

Страница 192: ...SKANTI SERVICE AGENTS Please refer to the list of agents at the SKANTI homepage on this Internet address http www skanti dk...

Страница 193: ...direct dial call cont d 6 33 Sending a direct dial call info 6 34 Sending a direct dial call cont d 6 35 Receiving distress alert info 6 36 Receiving distress alert 6 37 Acknowledging a distress alert...

Страница 194: ...DSC 9000 FRONT PANEL DSC OPERATION DSC 9000 FRONT PANEL 6 2 TRP 9250 TECHNICAL MANUAL...

Страница 195: ...nge the content of a selection field Move between commands Change list numbers Change between numbers and letters in alpha numeric fields Enters the content of a selection or entry field and moves to...

Страница 196: ...s key is kept pressed Quick flashing for 5 seconds red light A distress alert transmission is in progress Steady red light Distress alert will be automatically retransmitted A call other than distress...

Страница 197: ...all alarm sounds or either alarm sounds or the distress lamp is illuminated and when the aural distress alarm sounds Different on off patterns so it is possible to distinguish between distress alarm a...

Страница 198: ...the MAIN MENU STATUS or RX CALL states or if all control units are passive the display of a passive control unit shows If the active control unit is in any other state the display of a passive contro...

Страница 199: ...ge 6 50 6 50 6 52 6 52 6 53 6 53 6 19 6 45 6 68 6 68 6 68 6 70 6 70 6 54 6 48 7 18 7 18 7 21 7 19 7 19 7 20 7 20 7 20 7 18 7 21 7 22 6 55 6 58 6 54 6 54 6 55 6 58 6 64 6 67 6 66 6 59 6 60 6 62 6 63 6...

Страница 200: ...DISTRESS ALERT INFO To edit the Information release immediately DSC OPERATION DISTRESS ALERT INFO 6 8 TRP 9250 TECHNICAL MANUAL...

Страница 201: ...ert information will be transmitted when the key is released after the 6 seconds has elapsed DISTRESS Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony Keep pressing 5 sec to s...

Страница 202: ...he moment the Distress button is pressed and may be corrected manually by selecting EDIT Nature of Distress Selectable Options Fire explosion Flooding Collision Grounding Danger of capsizing Sinking D...

Страница 203: ...ISTRESS Position 55 59 N 133 22 W at 1229 UTC POSITION OK EDIT UNKNOWN DISTRESS Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony Change by or press Enter DISTRESS Position 55...

Страница 204: ...Distress frequencies in turn Note The Frequency is preset to 2187 5 kHz if watch receiver 1 is set to Distress watch MF DSC 9001 If a single frequency is selected the Distress Alert will be sent on t...

Страница 205: ...lert immediately or press to return to the Main Menu DSC FREQUENCY SELECTION 97 DISTRESS Tx 8414 5 Rx 8414 5 kHZ Change by or press Enter DISTRESS Position 55 59 N 133 22 W at 1229 UTC Undesignated di...

Страница 206: ...atically to telephony or telex mode as indicated in the call and to the appropriate distress frequency in the same band as the call After 3 minutes if a single frequency was selected the last line sho...

Страница 207: ...ved or is pressed Transmitting DISTRESS Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony Keep pressing 5 sec to send message DISTRESS Position 55 59 N 133 22 W at 1229 UTC Und...

Страница 208: ...nowledgement call END should be entered when communication is completed The display returns to STATUS display or to RX CALL if not all received calls have been read out and scanning is resumed on the...

Страница 209: ...ony The Transceiver is automatically set to the Distress traffic frequency 4 When communication is completed enter END RX CALL All ships from 001234567 Category Distress Distress ack Received on 8414...

Страница 210: ...SENDING DISTRESS RELAY CALL INFO To relay a received distress alert please refer to page 2 41 DSC OPERATION SENDING DISTRESS RELAY CALL INFO 6 18 TRP 9250 TECHNICAL MANUAL...

Страница 211: ...CALL Saved call Enter number 0 9 DIRECT DIAL SELECTIVE GROUP AREA ALL SHIPS TX CALL Selective to 001234567 Enter maritime mobile service identity TX CALL Selective to 001234567 Category Distress Chan...

Страница 212: ...automatically transmitted 5 times total duration approx 50 sec Following transmission of a selective call the receiver is set to the DSC RX frequency and awaits an acknowledgement within 5 minutes Fo...

Страница 213: ...by or press Enter DISTRESS RELAY Ship 123456789 Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony Change by or press Enter DISTRESS RELAY Ship 123456789 Position 55 59 N 133 2...

Страница 214: ...ransmitter are set to USB at the telephonydistress frequency in the same band If the handset is lifted off hook while the acknowledgement is displayed the telephony transmitter and receiver are set au...

Страница 215: ...utomatically set to the Distress traffic frequency 4 When communication is completed enter END DISTRESS RELAY Ship 123456789 Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony E...

Страница 216: ...tress Distress Urgency Urgency Safety Safety Ship s business Routine Type of subsequent communication Telecommand Selecable options USB telephony FEC telex ARQ telex For distresss category additionall...

Страница 217: ...subsequent communication telecommand Press TX CALL Saved call 0 9 DIRECT DIAL SELECTIVE GROUP AREA ALL SHIPS TX CALL Selective to 001234567 Enter maritime mobile service identity TX CALL Selective to...

Страница 218: ...wledgement within 5 minutes for selective calls and 25 seconds for direct dial calls All ships group and area calls require no acknowledgement When the transmission is completed the transceiver is set...

Страница 219: ...to 001234567 Category Routine USB telephony Press Enter to select DSC frequency DSC FREQUENCY SELECTION 08 NATIONAL Tx 2159 5 Rx 1624 5 Change by or press Enter TX CALL Selective to 001234567 Categor...

Страница 220: ...ode is displayed the mode and frequency is set as indicated in the call END should be entered when communication is completed For telephony calls just place the handset on hook The display returns to...

Страница 221: ...lly set to the mode and frequencies indicated in the acknowledgement 3 When communication is completed enter END RX ACKNOWLEDGEMENT from 001234567 Category Routine USB telephony Working freq Tx 2076 0...

Страница 222: ...he coast station has been programmed into the MMSI list When Enter is pressed the programmed name of the coast station will be shown next to the 9 digit MMSI number Alternatively the telephone list nu...

Страница 223: ...entering a List number Press TX CALL Saved call 0 9 Repeat Call DIRECT DIAL SELECTIVE GROUP AREA ALL SHIP TX CALL Direct dial to 002192000 Enter Maritime Mobile Service Identity TX CALL Direct dial to...

Страница 224: ...If quality is satisfactory the acknowledgement contains the same working frequencies The coast station then starts dialling the subscriber If the working channel quality evaluation indicates that qual...

Страница 225: ...Transmitting Tuning transmitter Awaiting ack on 1624 5 kHz Transmitting Checking for free channel Awaiting ack on 1813 0 kHz Transmitting Tuning transmitter TX CALL Direct dial to 002192000 Tel 424825...

Страница 226: ...SENDING A DIRECT DIAL CALL INFO DSC OPERATION SENDING A DIRECT DIAL CALL INFO 6 34 TRP 9250 TECHNICAL MANUAL...

Страница 227: ...om the coast station may contain information on the chargeable duration of the call RX ACKNOWLEDGEMENT from 002192000 Tel 42482544 End of call Duration 0 hours 6 min 35 sec QUIT SENDING A DIRECT DIAL...

Страница 228: ...ency ACK is replaced by RELAY See page 2 39 for acknowledgeing a Distress Alert and page 2 41 for Relaying a Distress Alert END should be entered when communication is completed The display returns to...

Страница 229: ...tress alert by telephony 3 When communication is completed enter END RX CALL Distress from 123456789 Position 55 59 N 133 22 W at 1229 UTC Undesignated distress USB telephony Received on 2187 5 kHz SE...

Страница 230: ...nowledge the DSC distress alert first Start of transmission is automatically delayed until 1 minute has passed since receipt of the Distress Alert In this periode the displays shows Call in progress E...

Страница 231: ...phony Received on 2187 5 kHz ACK END DSC distress acknowledgements are normally made by coast stations only CONTINUE RETURN Transmitting Checking for free channel Tuning transmitter Call in progress D...

Страница 232: ...ERT INFO The distress relay call is automatically transmitted 5 times Regarding receiving distress relay acknowledgement please refer to page 2 23 DSC OPERATION RELAYING A RECEIVED DISTRESS ALERT INFO...

Страница 233: ...ted distress USB telephony Received on 8414 5 kHz RELAY END TX CALL Selective to 001234567 Enter maritime mobile service identity DISTRESS RELAY Ship 123456789 Position 55 59 N 133 22 W at 1229 UTC Un...

Страница 234: ...e appropriate distress and safety frequency in the same band as the call END should be entered when communication is completed The display returns to STATUS or to RX CALL if not all received calls hav...

Страница 235: ...ny 3 When communication is completed enter END RX CALL All ships from 001234567 Category Distress Distress relay Received on 8414 5 kHz MORE DISTRESS RELAY Ship 123456789 Position 55 59 N 133 22 W at...

Страница 236: ...has been read out If the call does not contain mode information ACCEPT is omitted If SET UP is entered the mode and frequency of the transceiver is set as indicated in the call END should be entered w...

Страница 237: ...is deleted when the capacity is exceeded To see the content of the store press RX CALLS selects next or previous call displays the complete call RX CALLS 1229 UTC 1 JUL 1992 Distress call from 123456...

Страница 238: ...e transceiver is set to the mode and frequencies indicated in the acknowledgement call by pressing Enter or for telephony calls lifting the handset off hook within one minute END should be entered whe...

Страница 239: ...tomatically performed RX CALL Selective to 001234567 Category Routine USB telephony Working freq TX 8222 0 RX 8746 0 Received on 8436 5 kHz ACK END TX ACKNOWLEDGEMENT to 001234567 Category Routine USB...

Страница 240: ...t a busy signal to the calling subscriber The coast station evaluates the working channel quality during the DSC call If quality is satisfactory the acknowledgement contains the same working frequenci...

Страница 241: ...from the coast station may contain information on the chargeable duration of the call Awaiting ack on 1813 0 kHz Transmitting Tuning transmitter END Awaiting ack on 1813 0 kHz Transmitting Checking fo...

Страница 242: ...eiver 1 DSC watch receiver 1 s watch frequency or frequencies DSC watch receiver 2 DSC watch receiver 2 s watch frequency or frequencies Time UTC may be set in the programming menu Automatic acknowled...

Страница 243: ...an additional DU 9006 configured as a DSC watch receiver continuously on Its status is selelected in the configuration menu Note The STATUS line is empty if None is selected by configuration DSC watc...

Страница 244: ...nsetocallscontainingatelephonytelecommandwillcontain Unabletocomply andtheadditional message selected Automatic acknowledgement transmission takes place only if enabled by automatic ack programming Au...

Страница 245: ...list The arrow keys will switch between the selected frequency numbers The Enter key will display the frequencies selected and the arrow keys wil now move between the frequencies of the DSC frequency...

Страница 246: ...ions only press PROGRAMMING Automatic acknowledgement POLLING POSITION OTHER PROGRAMMING Aut ack of polling calls Specific stations only Change by or press Enter PROGRAMMING Aut ack of polling calls S...

Страница 247: ...s press PROGRAMMING Aut ack of position calls Specific stations only 002191000 _ Enter MMSI use for any digit PROGRAMMING Automatic acknowledgement POLLING POSITION OTHER PROGRAMMING Aut ack of other...

Страница 248: ...dating Select EDIT Press Enter the latitude Press Select S or N using an arrow key Press Enter the longtitude Press Select E or W using an arrow key Press PROGRAMMING Position 55 59 N 133 20 W at 1229...

Страница 249: ...12 hours have elapsed since the last updating the time will be deleted PROGRAMMING Position 55 59 N 133 20 W at 1229 UTC Enter the time of the position PROGRAMMING Position 55 59 N 133 20 W at 1229 UT...

Страница 250: ...bove options and Enter selects the displayed option and returns to STATUS menu Print Lists PROGRAMMING PRINTER LISTS The Print Lists menu allows selection of Print short dial list Print DSC frequency...

Страница 251: ...turn to the STATUS display PROGRAMMING Clock setting 1229 UTC Enter UTC time PROGRAMMING Clock setting 1229 UTC 12 Enter day of month PROGRAMMING Clock setting 1229 UTC 12 Jun Change by or press Enter...

Страница 252: ...nd CALL ALARM Select for how long the call alarm shall last using the arrow keys Press Select sound type C or D using an arrow key Press PROGRAMMING Distress alarm sound Type A Volume Change by or pre...

Страница 253: ...the loudspeaker Key beep sound KEY BEEP Select the volume level using the arrow keys Press to return to the STATUS display PROGRAMMING Call alarm sound Duration 5 Type C Volume PROGRAMMING Call alarm...

Страница 254: ...ng for the indicators using the arrow keys Press to return to the STATUS display The light in the Distress and Call indicators cannot be reduced completely PROGRAMMING Backlight Indicators Day Night C...

Страница 255: ...ING SETTINGS CONTRAST Select the contrast setting using the arrow keys Press to return to the STATUS display PROGRAMMING Contrast setting Change by or press Enter PROGRAMMING CONTRAST SETTING DSC OPER...

Страница 256: ...uency Press If all fields are empty or 0 the number is deleted from the list The distress and safety frequencies 94 99 cannot be edited The pre programmed DSC frequency list is printed on the next pag...

Страница 257: ...7 0 19 INTER 3 8416 0 8437 5 20 INTER 1 12577 5 12657 0 21 INTER 2 12578 0 12657 5 22 INTER 3 12578 5 12658 0 23 INTER 1 16805 0 16903 0 24 INTER 2 16805 5 16903 5 25 INTER 3 16806 0 16904 0 26 INTER...

Страница 258: ...when composing a TX CALL When Enter is pressed the name and the nine digit MMSI number is displayed When entering an unprogrammed list number the illegal key sound is given and the number is deleted I...

Страница 259: ...m the list Either the telephone number or the telephone list number 1 99 may be entered when composing a Direct dial call When Enter is pressed the telephone number and the name is displayed When ente...

Страница 260: ...displayed Press to return to the STATUS display The program version and date is displayed if selecting DU If an additional DU is connected the program version and date for both units are shown DU 2 d...

Страница 261: ...return to status display The error code consists of step number 2 digits indication of previous faults 1 digit 0 no 1 yes and failure type 1 digit If an additional DU is connected a selftest on that...

Страница 262: ...row keys Press to performe the audio test Adjust the volume level using the arrow keys Press to end the test and return to the status display TEST RX audio WATCH 1 WATCH 2 TRANSCEIVER TEST Watch 1 RX...

Страница 263: ...ncy in this test CONTINUE END TX CALL Selective to 00123456 Enter the maritime mobile service identity TX CALL Selective to 00123456 Press Enter to select DSC frequency DSC FREQUENCY SELECTION 94 DIST...

Страница 264: ...DSC OPERATION 6 72 TRP 9250 TECHNICAL MANUAL...

Страница 265: ...nnections for DCU without mounting bracket 7 12 Connectors 7 13 Earth connections 7 13 Net connector DCU 9000 7 14 Mounting bracket terminal board 7 15 Aux connector DCU 9000 7 16 Installation configu...

Страница 266: ...DSC INSTALLATION 7 DSC INSTALLATION Table of Contents 7 2 TRP 9250 TECHNICAL MANUAL...

Страница 267: ...the mounting bracket may be installed behind a bulkhead or a console panel for low profile mounting Fig 8a and 8b at page 7 7 and fig 9a and 9b at page 7 8 shows how flush mounting may be obtained an...

Страница 268: ...DCU 9000 WITH MOUNTING BRACKET Fig 5 DSC INSTALLATION DCU 9000 WITH MOUNTING BRACKET 7 4 TRP 9250 TECHNICAL MANUAL...

Страница 269: ...g 6 1 Space for cable entry min 50 Dimensions are in mm Tolerance 1 mm Centre of Gravity Weight DCU 1 2 Kg Weight Mounting Bracket 0 7 Kg Mounting Options DCU 9000 INSTALLATION WITH MOUNTING BRACKET D...

Страница 270: ...MOUNTING Fig 7 1 Space for cable entry min 50 Dimensions are in mm Tolerance 1 mm Centre of Gravity Weight DCU 1 2 Kg Weight Mounting Bracket 0 7 Kg Mounting Options DSC INSTALLATION DCU 9000 INSTALLA...

Страница 271: ...Weight DCU 1 2 Kg Tolerance 1 mm Weight Mounting Bracket 0 7 Kg Centre of Gravity Construction drawing for Fixture Fig 8b 1 Customize to Bulkhead thickness Dimensions are in mm Tolerance 0 2 mm 1 DCU...

Страница 272: ...Dimensions are in mm Weight DCU 1 2 Kg Tolerance 1 mm Weight Mounting Bracket 0 7 Kg Centre of Gravity Construction drawing for Fixture Fig 9b Dimensions are in mm Tolerance 0 2 mm DSC INSTALLATION D...

Страница 273: ...TERMINAL BOARD MOUNTING OPTIONS NORMAL MOUNTING OF TERMINAL BOARD Fig 10a 180 MOUNTING OF TERMINAL BOARD Fig 10b TERMINAL BOARD MOUNTING OPTIONS DSC INSTALLATION TRP 9250 TECHNICAL MANUAL 7 9...

Страница 274: ...T Fig 11 1 Space for cable entry min 100 Dimensions are in mm Tolerance 1 mm Centre of Gravity Weight 1 2 Kg Two M5x40 bolts included Mounting Options DSC INSTALLATION DCU 9000 WITHOUT MOUNTING BRACKE...

Страница 275: ...OUNTING Fig 12a Dimensions are in mm Weight DCU 1 2 Kg Tolerance 1 mm Centre of Gravity Construction drawing for Fixture Fig 12b Dimensions are in mm Tolerance 0 2 mm DCU 9000 WITHOUT MOUNTING BRACKET...

Страница 276: ...CABLE CONNECTIONS FOR DCU WITHOUT MOUNTING BRACKET Fig 13 DSC INSTALLATION CABLE CONNECTIONS FOR DCU WITHOUT MOUNTING BRACKET 7 12 TRP 9250 TECHNICAL MANUAL...

Страница 277: ...Fig 18 DCU 9000 EARTH CONNECTION Skanti part no 772 000 17 Wire specification Recommended wire dimension min 2 5 mm Sq Wire length as short as possible EARTH CONNECTIONS DSC INSTALLATION TRP 9250 TECH...

Страница 278: ...Twisted pairs 1 and 6 2 and 3 4 and 5 6 and 7 8 and 9 15mm 5mm screen conductor Identify twisted pairs Before contacts of plug are soldered slide the plastic cover over the cable After the contacts a...

Страница 279: ...MOUNTING BRACKET TERMINAL BOARD Fig 22 MOUNTING BRACKET TERMINAL BOARD DSC INSTALLATION TRP 9250 TECHNICAL MANUAL 7 15...

Страница 280: ...AUX CONNECTOR DCU 9000 Fig 23 SKANTI part no 751 000 65 Cable specification Acommodate cable outer diameter from 4 4 to 11 0 mm DSC INSTALLATION AUX CONNECTOR DCU 9000 7 16 TRP 9250 TECHNICAL MANUAL...

Страница 281: ...nally protected 12 GND 13 NMEA Rx Input Opto isolated serial interface for navigation equipment NMEA 0183 14 n c 15 n c Table 4 The printer interface is opto isolated with driver power delivered from...

Страница 282: ...page 3 47 Therefore check the numbers carefully for correctness before pressing Enter Configuration of Group ID One or more group call identities may be assigned to the station Group call identity nu...

Страница 283: ...nts To change configuration select INTERFACES in the CONFIGURATION menu and press Enter Select RADIO in the Interfaces menu and press Enter Select CONTROL in the Radio interface menu and press Enter S...

Страница 284: ...lay outs in the status display Distress watch MF Distress watch MF HF Calling watch None One of the lay outs may be selected for each watch receiver To change the configuration select WATCH in the CON...

Страница 285: ...n the desired activation conditions Distress alarm only Call alarm only Distress Call alarm Distress alarm lamp Configuration of Formats Certain call formats may be omitted This enables the DSC 9000 t...

Страница 286: ...use mode Data V 21 Data V 22 Data V 22 bis Data V 23 Data V 26 bis Data V 26 ter Data V 27 ter Data V 32 USB telephony AM telephony Distress relay FEC telex ARQ telex RTTY receive RTTY A1A CW tape Shi...

Страница 287: ...Y SKANTI PART NUMBER Mounting bracket for DCU 9000 1 107 810 40 D sub connector 9 pole male 2 751 000 64 D sub connector 15 pole male 1 751 000 65 Tab connector female 1 772 000 17 ACCESSORIES INCLUDE...

Страница 288: ...DSC INSTALLATION 7 24 TRP 9250 TECHNICAL MANUAL...

Страница 289: ...TRP 1250 Technical Manual Skandinavisk Teleindustri SKANTI A S 4 Lautrupvang DK 2750 Ballerup Denmark Phone 45 44 74 84 00 Fax 45 44 74 84 01 Telex 37292 skanti dk E mail skanti skanti dk http www ska...

Отзывы: