AURAL ALARM SIGNALS
Distress Alarm:
User-programmable sound indicating that a distress or urgency call
has been received. Remain activated until a key is pressed
Call alarm:
User-programmable sound indicating that a call (other than distress
or urgency) has been received. Remain activated for 1/4 - 4 minutes
(programmable) or until a key is pressed or, for Direct-dial and
Selective telephony calls, the handset of the radiotelephone is lifted
off-hook.
REMOTE ALARMS
External alarm devices may be connected to DSC 9000 and configurated to be active when
- the aural distress alarm sounds, or
- the aural call alarm sounds, or
- either alarm sounds *), or
- the distress lamp is illuminated and when
the aural distress alarm sounds
*)Different on/off patterns so it is possible to distinguish between distress alarm and call alarm.
REMOTE ACTIVATION OF DISTRESS ALERT
An external push button may be connected to the equipment for remote initiation of a distress
alert.
The external push button may be combined with a lamp configurated to follow the distress lamp.
The external push button is operated in the same way as the Distress key on DCU 9000. To
initiate a distress alert press the push-button for 6 sec (until the distress lamp stops
quick-flashing and shows steady light). Then release. If not released within 5 s transmission
does not start.
KEYS AND INDICATORS
DSC OPERATION
TRP 9250 TECHNICAL MANUAL
6-5
Содержание TRP 9250
Страница 1: ...TRP 9250 250 Watt Radio Transceiver for MF HF SKANTI...
Страница 5: ...ff qom VORM qb ekf i j kr i...
Страница 7: ...INTRODUCTION 1 2 TRP 9250 TECHNICAL MANUAL...
Страница 17: ...OPERATION 2 OPERATION Table of Contents 2 2 TRP 9250 TECHNICAL MANUAL...
Страница 73: ...INSTALLATION 3 INSTALLATION Table of contents 3 2 TRP 9250 TECHNICAL MANUAL...
Страница 99: ...INSTALLATION 3 28 TRP 9250 TECHNICAL MANUAL...
Страница 139: ...TECHNICAL DESCRIPTION 4 TECHNICAL DESCRIPTION Table of Contents 4 2 TRP 9250 TECHNICAL MANUAL...
Страница 147: ......
Страница 149: ......
Страница 150: ......
Страница 152: ...SERVICE 5 SERVICE Table of contents 5 2 TRP 9250 TECHNICAL MANUAL...
Страница 166: ...SERVICE POWER PROTECTION 5 16 TRP 9250 TECHNICAL MANUAL...
Страница 174: ...SERVICE SERVICE RELATED PROG KEY OPERATIONS 5 24 TRP 9250 TECHNICAL MANUAL...
Страница 194: ...DSC 9000 FRONT PANEL DSC OPERATION DSC 9000 FRONT PANEL 6 2 TRP 9250 TECHNICAL MANUAL...
Страница 226: ...SENDING A DIRECT DIAL CALL INFO DSC OPERATION SENDING A DIRECT DIAL CALL INFO 6 34 TRP 9250 TECHNICAL MANUAL...
Страница 264: ...DSC OPERATION 6 72 TRP 9250 TECHNICAL MANUAL...
Страница 266: ...DSC INSTALLATION 7 DSC INSTALLATION Table of Contents 7 2 TRP 9250 TECHNICAL MANUAL...
Страница 268: ...DCU 9000 WITH MOUNTING BRACKET Fig 5 DSC INSTALLATION DCU 9000 WITH MOUNTING BRACKET 7 4 TRP 9250 TECHNICAL MANUAL...
Страница 279: ...MOUNTING BRACKET TERMINAL BOARD Fig 22 MOUNTING BRACKET TERMINAL BOARD DSC INSTALLATION TRP 9250 TECHNICAL MANUAL 7 15...
Страница 288: ...DSC INSTALLATION 7 24 TRP 9250 TECHNICAL MANUAL...