background image

2  |   Sinterit INTERTEK Vacuum Cleaner USER MANUAL  

Important safety instructions!

When using an electrical appliance, basic precautions should always be followed, including the following:
1)  READ ALL INSTRUCTIONS BEFORE USING THE SINTERIT INTERTEK VACUUM CLEANER.
2)  WARNING – To reduce the risk of fire, electric shock, or injury:

• 

Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.

• 

Do not use outdoors or on wet surfaces.

• 

Use only as described in this manual. Use only manufacturer’s recommended attachments.

• 

Do not use with damaged cable or plug. If the appliance is not working as it should, has been dropped, damaged, left 

outdoors, or dropped into water, return it to a service centre.

• 

Do not pull or carry by cable, use the cable as a handle, close a door on cable, or pull cable around sharp edges or 

corners. Do not run appliance over cord. Keep cord away from heated surfaces.

• 

Do not unplug by pulling on the cable. To unplug, grasp the plug, not the cable.

• 

Do not handle plug or appliance with wet hands.

• 

Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything 
that may reduce air flow.

• 

Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.

• 

Turn off all controls before unplugging.

• 

Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.

• 

Connect to a properly grounded outlet only. 

• 

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

• 

Do not use without dust bag and/or filters in place.

Save these instructions!

The machine is supplied with: User manual, Test Sheet, Warranty Slip, Approval Certificate. 

This manual provides all the information needed to use and service your Sinterit INTERTEK Vacuum Cleaner. Good 
operation and durability depend on proper maintenance and careful use. 

Before leaving the factory, this particular model has undergone thorough tests to ensure the utmost reliability. However, 
make sure that the vacuum cleaner has not been damaged during transport in a way that could  affect its operation and 
safety. 

This manual should be considered an integral part of the vacuum cleaner and must be kept together with the unit until 
this is scrapped. In case of loss or damage to the manual, ask Sinterit for a new copy or visit www.sinterit.com/support-
page/ and download the PDF. 

This manual must be kept in a place accessible to all the personnel charged with operating and servicing the vacuum 
cleaner. 

Before using the machine, prepare and train yourself by reading this manual carefully. Use of the machine by untrained 
and unauthorised persons is forbidden. The employer must inform and train the user according to the provisions of 
applicable laws.

Failure to observe basic safety regulations and warnings could cause accidents during vacuum cleaner operation, 
maintenance and repair. Operators should be aware of potential hazards and be trained and skilled enough. They should 
also have the right  tools. 

SINTERIT shall under no circumstances be deemed liable for accidents or damage caused by use of the vacuum cleaner 
by personnel not properly trained or who use it in an improper manner, as well as by even partial failure to comply with 
the safety regulations and intervention procedures indicated in this manual. 

In case of any doubts, always immediately call the Sinterit Support.

Содержание ATEX Vacuum Cleaner

Страница 1: ...efers to product Atex Vacuum Cleaner NRTL certified ETL Intertek listed Read the instruction manual before using the device Internal device construction differences might appear betweet products with...

Страница 2: ...e these instructions The machine is supplied with User manual Test Sheet Warranty Slip Approval Certificate This manual provides all the information needed to use and service your Sinterit INTERTEK Va...

Страница 3: ...ng repair and maintenance 13 G Toxic and dangerous materials 13 H Safety plates specification tag and symbols 14 I Scrapping 15 6 Initial startup of the Sinterit INTERTEK Vacuum Cleanerr after deliver...

Страница 4: ...regulations and intervention procedures indicated in this manual The safety warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the op...

Страница 5: ...instructions before taking action 2 Contents of the Sinterit INTERTEK Vacuum Cleaner pack The Sinterit INTERTEK Vacuum Cleaner a package for the additional equipment Sinterit INTERTEK Vacuum Cleaner U...

Страница 6: ...m external wire with grounding clamp Image 3 Back view of the Sinterit INTERTEK Vacuum Cleaner 8 Power cable 9 Suction hose connector 10 Filtering chamber s handles 11 Power cable hanger 14 15 13 12 I...

Страница 7: ...aner available in options 110 i 230 V with ATEX Z22 certification 110 V with Intertek certification Waiting time depends on the selected option GENERAL Category Vacuum cleaner Type Industrial PACKAGIN...

Страница 8: ...he phonometric test results on this specific model correspond to the following acoustic pressure at 1 meter distance from the vacuum and at 1 60 meter height where there is the noisiest part of the va...

Страница 9: ...o wear or damage Applied directives The following directives apply to the vacuum cleaner described in this manual Ordinary Locations UL 1017 CSA C22 2 N 243 10 Hazardous Locations ISA 12 12 01 2016 CS...

Страница 10: ...LOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ignitible concentrations Do not connect or disconnect when energized ATTENTION Risk of crushing upper limbs whil...

Страница 11: ...these Periodically check the mains power cable to ensure it is not damaged In the event of the cable plugs or couplings being replaced make sure these are protected against water spray and check mech...

Страница 12: ...ied atmosphere area after having disconnected and unplugged the machine and only after 10 minutes from unplugging Non classified atmosphere which means in an area with non potentially explosive atmosp...

Страница 13: ...r and therefore cancel this certification Any alterations to the appliance can only be made by Sinterit Support WARNING NON SPARKING DEFLECTOR The vacuum cleaner is provided with a brassy non sparking...

Страница 14: ...to CSA Std C22 2 68 C22 2 243 C22 2 213 MOD Sinterit INTERTEK Vacuum Cleaner ELECT RATING S N 104 127V 60 Hz 14A 1 1KW 1PH 200218356 MARKING CLASSII DIVISION 2 GROUPS F G AMBIENT TEMP RANGE 0 C T 40...

Страница 15: ...enough to fully protect against all the hazards that could arise during vacuum cleaner operation These will have to be integrated with common sense and the experience of the operator both of which ar...

Страница 16: ...nd injury 1 Set on the castors brake 6 to ensure that the machine is stable 2 Check that the nut of the grounding system 7 on the vacuum cleaner is tightly screwed in 3 Check the components inside the...

Страница 17: ...the sides of the container near the guide pins while locking Perform the container locking operation by means of the levers located on the side USING BOTH HANDS Now you have two options you can use IN...

Страница 18: ...ner safety plate 4 Ensure that the Power cable 8 and the optional extension are in perfect conditions 5 Connect the vacuum cleaner grounding system 7 to a conductive surface 6 Plug the Power cable int...

Страница 19: ...let nozzle by hand Image 11 Incorrect and correct removing the powder from the print chamber 3 The capacity of the collected material in each device should not exceed 3 4 of the container After each c...

Страница 20: ...ot to damage the Power cable 7 Disconnect the internal grounding 16 from the connector 21 to get to the Main Star filter Image 14 5 21 16 Image 13 Release the Release fasteners Image 14 Disconnect the...

Страница 21: ...ical maintenance The Safety Manager has the precise duty of determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there...

Страница 22: ...faults or defects Screws and nuts must always be tightened Clean the Non sparkling deflector 19 inside on a regular basis to prevent dust accumulation inside the Filtering chamber Remove the Motor Hea...

Страница 23: ...et to the Main Star filter Image 16 5 21 16 Image 15 Release the Release fasteners Image 16 Disconnect the internal grounding 16 with connector 21 7 Remove the Main Star filter Watch out for the powde...

Страница 24: ...POSSIBLE FAULT RECOMMENDED REMEDY The vacuum cleaner fails to start No power 1 Check the power mains supply 2 Check the integrity of the plug and Power cable Dust leaking out Perforated Antistatic ho...

Страница 25: ...nly with the product called Sinterit INTERTEK Vacuum Cleaner Due to the constant development of Sinterit s products the information contained in this manual specifications and markings are subject to...

Страница 26: ...malfunction caused by dismantling alterations tuning or other changes of the product by a client or any third party made without written consent of Sinterit damages abnormalities or malfunction cause...

Страница 27: ...e liquid produced vapours or combustible liquid produced vapours are not likely to exist under normal operating conditions Groups F G Material Properties F Carbonaceous Dusts G Non Conductive Dusts fl...

Страница 28: ...SINTERIT Sp z o o ul Nad Drwina 10 bud B3 30 741 Krakow Poland www sinterit com Contact 48 570 967 854...

Отзывы: