B. PERIODICAL MAINTENANCE

ATTENTION!

Any maintenance or cleaning job must only be executed in a NOT-CLASSIFIED 
atmosphere, which means in an area with non potentially explosive atmosphere.

EVERY DAY

• 

Make sure that the Filtering chamber 

4

 is not full. It is recommended to empty the Filtering 

chamber when the collected material fills 3⁄4 of its maximum capacity. 

• 

Check the condition of the Antistatic hose 

A

 and other accessories to be used. Any hole, 

crack or fissure in the Antistatic hose will reduce suction power and disperse the vacuumed 
dust into the environment.

EVERY WEEK

• 

Clean the vacuum regularly, removing dust deposits. The thickness of the deposited dust 
must not exceed 2 mm. 

• 

Remove any layers of dust on the castors 

6

.

• 

Check that the nut of the grounding system 

7

 (on the vacuum cleaner) is tightly screwed in.

EVERY 

6 MONTHS

• 

Check  that  the  head  basement  sheath,  the  filter  holding  ring  sheath  (clamp) 

22

 and the 

Filtering chamber sheath are hermetic. 

• 

The electrical units (plugs, switches, cables and so on) must have no faults or defects. 

• 

Screws and nuts must always be tightened. 

• 

Clean the Non-sparkling deflector 

19

 inside on a regular basis to prevent dust accumulation 

inside the Filtering chamber. 

• 

Remove the Motor Head protection cap 

15

 protecting the turbine and vacuum any dust 

deposit within the suction unit. 

• 

Check the filter 

17

20

 conditions. 

• 

The Main Star Filter 

17

 must not be too breathable.

• 

There must be no cuts and holes and the sewing must not be worn. Check that the Main 
Star Filter holding ring is tightened. In the event any of the aforesaid circumstances occur, 
replace the filter as indicated in section C this chapter. 

MOREOVER

• 

For Non-sparkling deflector 

19

: please check periodically its condition. In case it’s too worn, 

there is no guarantee of the required INTERTEK protection.

ATTENTION!

To  ensure  the  vacuum  efficiency  and  safety,  Sinterit  recommends  an  overhaul  at  the  
Manufacturer’s technical service workshop every 24 months.

ATTENTION!

In case of dust outflow from the engine, turn off the vacuum immediately and call the authorised 
service centre applying for assistance.

WARNING!

Any maintenance and repair operation not included in the above-mentioned ones must be 
executed by the Manufacturers technical service workshop or by Sinterit authorised service 
centres. 

Содержание ATEX Vacuum Cleaner

Страница 1: ...efers to product Atex Vacuum Cleaner NRTL certified ETL Intertek listed Read the instruction manual before using the device Internal device construction differences might appear betweet products with...

Страница 2: ...e these instructions The machine is supplied with User manual Test Sheet Warranty Slip Approval Certificate This manual provides all the information needed to use and service your Sinterit INTERTEK Va...

Страница 3: ...ng repair and maintenance 13 G Toxic and dangerous materials 13 H Safety plates specification tag and symbols 14 I Scrapping 15 6 Initial startup of the Sinterit INTERTEK Vacuum Cleanerr after deliver...

Страница 4: ...regulations and intervention procedures indicated in this manual The safety warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the op...

Страница 5: ...instructions before taking action 2 Contents of the Sinterit INTERTEK Vacuum Cleaner pack The Sinterit INTERTEK Vacuum Cleaner a package for the additional equipment Sinterit INTERTEK Vacuum Cleaner U...

Страница 6: ...m external wire with grounding clamp Image 3 Back view of the Sinterit INTERTEK Vacuum Cleaner 8 Power cable 9 Suction hose connector 10 Filtering chamber s handles 11 Power cable hanger 14 15 13 12 I...

Страница 7: ...aner available in options 110 i 230 V with ATEX Z22 certification 110 V with Intertek certification Waiting time depends on the selected option GENERAL Category Vacuum cleaner Type Industrial PACKAGIN...

Страница 8: ...he phonometric test results on this specific model correspond to the following acoustic pressure at 1 meter distance from the vacuum and at 1 60 meter height where there is the noisiest part of the va...

Страница 9: ...o wear or damage Applied directives The following directives apply to the vacuum cleaner described in this manual Ordinary Locations UL 1017 CSA C22 2 N 243 10 Hazardous Locations ISA 12 12 01 2016 CS...

Страница 10: ...LOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ignitible concentrations Do not connect or disconnect when energized ATTENTION Risk of crushing upper limbs whil...

Страница 11: ...these Periodically check the mains power cable to ensure it is not damaged In the event of the cable plugs or couplings being replaced make sure these are protected against water spray and check mech...

Страница 12: ...ied atmosphere area after having disconnected and unplugged the machine and only after 10 minutes from unplugging Non classified atmosphere which means in an area with non potentially explosive atmosp...

Страница 13: ...r and therefore cancel this certification Any alterations to the appliance can only be made by Sinterit Support WARNING NON SPARKING DEFLECTOR The vacuum cleaner is provided with a brassy non sparking...

Страница 14: ...to CSA Std C22 2 68 C22 2 243 C22 2 213 MOD Sinterit INTERTEK Vacuum Cleaner ELECT RATING S N 104 127V 60 Hz 14A 1 1KW 1PH 200218356 MARKING CLASSII DIVISION 2 GROUPS F G AMBIENT TEMP RANGE 0 C T 40...

Страница 15: ...enough to fully protect against all the hazards that could arise during vacuum cleaner operation These will have to be integrated with common sense and the experience of the operator both of which ar...

Страница 16: ...nd injury 1 Set on the castors brake 6 to ensure that the machine is stable 2 Check that the nut of the grounding system 7 on the vacuum cleaner is tightly screwed in 3 Check the components inside the...

Страница 17: ...the sides of the container near the guide pins while locking Perform the container locking operation by means of the levers located on the side USING BOTH HANDS Now you have two options you can use IN...

Страница 18: ...ner safety plate 4 Ensure that the Power cable 8 and the optional extension are in perfect conditions 5 Connect the vacuum cleaner grounding system 7 to a conductive surface 6 Plug the Power cable int...

Страница 19: ...let nozzle by hand Image 11 Incorrect and correct removing the powder from the print chamber 3 The capacity of the collected material in each device should not exceed 3 4 of the container After each c...

Страница 20: ...ot to damage the Power cable 7 Disconnect the internal grounding 16 from the connector 21 to get to the Main Star filter Image 14 5 21 16 Image 13 Release the Release fasteners Image 14 Disconnect the...

Страница 21: ...ical maintenance The Safety Manager has the precise duty of determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there...

Страница 22: ...faults or defects Screws and nuts must always be tightened Clean the Non sparkling deflector 19 inside on a regular basis to prevent dust accumulation inside the Filtering chamber Remove the Motor Hea...

Страница 23: ...et to the Main Star filter Image 16 5 21 16 Image 15 Release the Release fasteners Image 16 Disconnect the internal grounding 16 with connector 21 7 Remove the Main Star filter Watch out for the powde...

Страница 24: ...POSSIBLE FAULT RECOMMENDED REMEDY The vacuum cleaner fails to start No power 1 Check the power mains supply 2 Check the integrity of the plug and Power cable Dust leaking out Perforated Antistatic ho...

Страница 25: ...nly with the product called Sinterit INTERTEK Vacuum Cleaner Due to the constant development of Sinterit s products the information contained in this manual specifications and markings are subject to...

Страница 26: ...malfunction caused by dismantling alterations tuning or other changes of the product by a client or any third party made without written consent of Sinterit damages abnormalities or malfunction cause...

Страница 27: ...e liquid produced vapours or combustible liquid produced vapours are not likely to exist under normal operating conditions Groups F G Material Properties F Carbonaceous Dusts G Non Conductive Dusts fl...

Страница 28: ...SINTERIT Sp z o o ul Nad Drwina 10 bud B3 30 741 Krakow Poland www sinterit com Contact 48 570 967 854...

Отзывы: