16 | Sinterit INTERTEK Vacuum Cleaner USER MANUAL
7. Preparing the machine to work
ATTENTION!
In the event of any component parts being damaged, do not proceed with installation. Notify the
manufacturer and reach an agreement on how to proceed.
ATTENTION!
•
The operator using the Sinterit INTERTEK Vacuum Cleaner always must
wear antistatic clothes and antistatic shoes.
•
The working environment and the floor must comply with antistatic
standards.
WARNING!
The vacuum cleaner can be shifted manually on flat grounds only. The vacuum cleaner heavy
weight may not allow the operator to shift it safely on slopes as it would be difficult to handle and
control the machine avoiding dangerous collisions which may cause damages and injury.
1. Set on the castors brake
6
to ensure that the machine is stable.
2. Check that the nut of the grounding system
7
(on the vacuum cleaner) is tightly screwed in.
3. Check the components inside the vacuum cleaner (Internal grounding
16
, Filter gasket
18
, Main Star filter
17
, inside
the Filtering chamber
4
).
a. Unlock the Release fasteners
5
between the filtering chamber
4
and the Motor Head
2
.
b. Grab the Motor Head handle
3
and lift it up and put it on the floor. Watch out! The Motor Head is very heavy!
c. Disconnect the internal grounding
16
with connector
21
(Image 9) to get to the Main Star filter
17
and the Filtering
chamber
4
.
21
16
Image 9. Disconnect the internal grounding
16
with connector
21
.
d. Check the condition of the Filter gasket
18
around the chamber.
e. Remove the Main Star filter and check its condition.
f. Check for unnecessary objects inside the chamber and the Non-sparkling deflector
19
condition.