background image

20  |   Sinterit INTERTEK Vacuum Cleaner USER MANUAL  

9. Cleaning the Filtering chamber

ATTENTION! 

Any  maintenance  or  cleaning  job  must  only  be  executed  in  NOT-
CLASSIFIED atmosphere, which means an area with a non potentially 
explosive atmosphere. 

ATTENTION! 

Before  starting  any  maintenance  or  cleaning  job,  always  wear  adequate  protective 
clothing, eyewear,  face mask, and/or gloves according to the type of job to be done. 

1.  Set on the castors brake to ensure that the machine is stable.
2.  Turn off the vacuum cleaner by switching the Power Switch from “1” to “0”.
3.  Disconnect the vacuum cleaner plug from the power supply. 
4.  Release the Antistatic hose from the Suction hose connector. 
5.  Release the two Release fasteners 

5

 that hold the Motor Head (Image 13). 

6.  Lift the Motor Head and rest this on a flat surface being careful not to damage the Power cable.
7.  Disconnect the internal grounding 

16

 from the connector 

21

 to get to the Main Star filter (Image 14). 

5

21

16

Image 13. Release the Release fasteners.

Image 14. Disconnect the internal grounding 

16

 with connector 

21

.

8.  Remove the Main Star filter. Watch out for the powder on the filter surface, especially underneath! Put the Main Star 

filter on a tray (you will avoid spilling powder around the area).

9.  Empty the Filtering chamber from the powder or dust into special containers. 

STOP! 

Empty the contents of the Filtering chamber into a special waste disposal 
container in accordance with laws applicable in the country where the vacuum 
cleaner is used. 

10. Put the Main Star filter back in place.
11. Connect the internal grounding!
12. Fit the Motor Head back on and secure with Release fasteners.

CAUTION!

Danger of crushing upper limbs when fitting and locking the Motor Head on the Filtering Chamber. 

13. Fit the necessary accessories, connect the power supply and grounding. Start working again.

Содержание ATEX Vacuum Cleaner

Страница 1: ...efers to product Atex Vacuum Cleaner NRTL certified ETL Intertek listed Read the instruction manual before using the device Internal device construction differences might appear betweet products with...

Страница 2: ...e these instructions The machine is supplied with User manual Test Sheet Warranty Slip Approval Certificate This manual provides all the information needed to use and service your Sinterit INTERTEK Va...

Страница 3: ...ng repair and maintenance 13 G Toxic and dangerous materials 13 H Safety plates specification tag and symbols 14 I Scrapping 15 6 Initial startup of the Sinterit INTERTEK Vacuum Cleanerr after deliver...

Страница 4: ...regulations and intervention procedures indicated in this manual The safety warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the op...

Страница 5: ...instructions before taking action 2 Contents of the Sinterit INTERTEK Vacuum Cleaner pack The Sinterit INTERTEK Vacuum Cleaner a package for the additional equipment Sinterit INTERTEK Vacuum Cleaner U...

Страница 6: ...m external wire with grounding clamp Image 3 Back view of the Sinterit INTERTEK Vacuum Cleaner 8 Power cable 9 Suction hose connector 10 Filtering chamber s handles 11 Power cable hanger 14 15 13 12 I...

Страница 7: ...aner available in options 110 i 230 V with ATEX Z22 certification 110 V with Intertek certification Waiting time depends on the selected option GENERAL Category Vacuum cleaner Type Industrial PACKAGIN...

Страница 8: ...he phonometric test results on this specific model correspond to the following acoustic pressure at 1 meter distance from the vacuum and at 1 60 meter height where there is the noisiest part of the va...

Страница 9: ...o wear or damage Applied directives The following directives apply to the vacuum cleaner described in this manual Ordinary Locations UL 1017 CSA C22 2 N 243 10 Hazardous Locations ISA 12 12 01 2016 CS...

Страница 10: ...LOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ignitible concentrations Do not connect or disconnect when energized ATTENTION Risk of crushing upper limbs whil...

Страница 11: ...these Periodically check the mains power cable to ensure it is not damaged In the event of the cable plugs or couplings being replaced make sure these are protected against water spray and check mech...

Страница 12: ...ied atmosphere area after having disconnected and unplugged the machine and only after 10 minutes from unplugging Non classified atmosphere which means in an area with non potentially explosive atmosp...

Страница 13: ...r and therefore cancel this certification Any alterations to the appliance can only be made by Sinterit Support WARNING NON SPARKING DEFLECTOR The vacuum cleaner is provided with a brassy non sparking...

Страница 14: ...to CSA Std C22 2 68 C22 2 243 C22 2 213 MOD Sinterit INTERTEK Vacuum Cleaner ELECT RATING S N 104 127V 60 Hz 14A 1 1KW 1PH 200218356 MARKING CLASSII DIVISION 2 GROUPS F G AMBIENT TEMP RANGE 0 C T 40...

Страница 15: ...enough to fully protect against all the hazards that could arise during vacuum cleaner operation These will have to be integrated with common sense and the experience of the operator both of which ar...

Страница 16: ...nd injury 1 Set on the castors brake 6 to ensure that the machine is stable 2 Check that the nut of the grounding system 7 on the vacuum cleaner is tightly screwed in 3 Check the components inside the...

Страница 17: ...the sides of the container near the guide pins while locking Perform the container locking operation by means of the levers located on the side USING BOTH HANDS Now you have two options you can use IN...

Страница 18: ...ner safety plate 4 Ensure that the Power cable 8 and the optional extension are in perfect conditions 5 Connect the vacuum cleaner grounding system 7 to a conductive surface 6 Plug the Power cable int...

Страница 19: ...let nozzle by hand Image 11 Incorrect and correct removing the powder from the print chamber 3 The capacity of the collected material in each device should not exceed 3 4 of the container After each c...

Страница 20: ...ot to damage the Power cable 7 Disconnect the internal grounding 16 from the connector 21 to get to the Main Star filter Image 14 5 21 16 Image 13 Release the Release fasteners Image 14 Disconnect the...

Страница 21: ...ical maintenance The Safety Manager has the precise duty of determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there...

Страница 22: ...faults or defects Screws and nuts must always be tightened Clean the Non sparkling deflector 19 inside on a regular basis to prevent dust accumulation inside the Filtering chamber Remove the Motor Hea...

Страница 23: ...et to the Main Star filter Image 16 5 21 16 Image 15 Release the Release fasteners Image 16 Disconnect the internal grounding 16 with connector 21 7 Remove the Main Star filter Watch out for the powde...

Страница 24: ...POSSIBLE FAULT RECOMMENDED REMEDY The vacuum cleaner fails to start No power 1 Check the power mains supply 2 Check the integrity of the plug and Power cable Dust leaking out Perforated Antistatic ho...

Страница 25: ...nly with the product called Sinterit INTERTEK Vacuum Cleaner Due to the constant development of Sinterit s products the information contained in this manual specifications and markings are subject to...

Страница 26: ...malfunction caused by dismantling alterations tuning or other changes of the product by a client or any third party made without written consent of Sinterit damages abnormalities or malfunction cause...

Страница 27: ...e liquid produced vapours or combustible liquid produced vapours are not likely to exist under normal operating conditions Groups F G Material Properties F Carbonaceous Dusts G Non Conductive Dusts fl...

Страница 28: ...SINTERIT Sp z o o ul Nad Drwina 10 bud B3 30 741 Krakow Poland www sinterit com Contact 48 570 967 854...

Отзывы: