background image

10  |   Sinterit INTERTEK Vacuum Cleaner USER MANUAL  

B. GENERAL SAFETY RULES

WARNING!

• 

Equipment should be used only by trained staff in accordance with all applicable national 
and local codes (NFPA70, C.E.C., NFPA 652, etc.).

• 

Without  prejudice  for  the  above,  it  is  recommended  to  keep  the  machine  construction 
complying with the safety standards prescribed by the NFPA 70 (NEC) and C.E.C.

WARNING!

• 

Only adults should use the vacuum cleaner.

• 

When using the machine, mind other people, especially children. 

WARNING!

• 

The vacuum cleaner must not be operated in a corrosive or explosive 
environment. 

• 

Avoid prolonged contact with solvents and inhaling their vapours. 

• 

Avoid using the device close to open flames or sources of heat.

• 

To reduce the risk of ignition of hazardous atmospheres, disconnect the 
equipment from the supply circuit before opening.

• 

Keep assembly tightly closed when in operation.

STOP!

EXPLOSION HAZARD.

• 

Do not disconnect while the circuit is live or unless the area is free of 
ignitible concentrations.

• 

Do not connect or disconnect when energized.

ATTENTION! 

• 

Risk of crushing upper limbs while fitting and locking the material container 
on the vacuum cleaner. 

• 

Never place hands between the Filtering chamber and Motor Head while 
locking. 

• 

Do not put hands on the sides of the container near the guide pins while 
locking.

• 

Perform the container locking operation by means of the levers located on 
the side, USING BOTH HANDS!

ATTENTION! 

When restoring original working conditions, the appointed personnel should make sure that 
at the end of the operating procedure, proper vacuum cleaner operation safety conditions are 
restored, especially the safety devices and the protective guards.

WARNING!

• 

Never leave miscellaneous materials on the horizontal protection cap.

• 

The Motor Head’s protection cap containing moving parts must not be removed by the user.

• 

Make sure all the guards and protection devices are in place and that all the safety devices 
are in place and working properly. 

Содержание ATEX Vacuum Cleaner

Страница 1: ...efers to product Atex Vacuum Cleaner NRTL certified ETL Intertek listed Read the instruction manual before using the device Internal device construction differences might appear betweet products with...

Страница 2: ...e these instructions The machine is supplied with User manual Test Sheet Warranty Slip Approval Certificate This manual provides all the information needed to use and service your Sinterit INTERTEK Va...

Страница 3: ...ng repair and maintenance 13 G Toxic and dangerous materials 13 H Safety plates specification tag and symbols 14 I Scrapping 15 6 Initial startup of the Sinterit INTERTEK Vacuum Cleanerr after deliver...

Страница 4: ...regulations and intervention procedures indicated in this manual The safety warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the op...

Страница 5: ...instructions before taking action 2 Contents of the Sinterit INTERTEK Vacuum Cleaner pack The Sinterit INTERTEK Vacuum Cleaner a package for the additional equipment Sinterit INTERTEK Vacuum Cleaner U...

Страница 6: ...m external wire with grounding clamp Image 3 Back view of the Sinterit INTERTEK Vacuum Cleaner 8 Power cable 9 Suction hose connector 10 Filtering chamber s handles 11 Power cable hanger 14 15 13 12 I...

Страница 7: ...aner available in options 110 i 230 V with ATEX Z22 certification 110 V with Intertek certification Waiting time depends on the selected option GENERAL Category Vacuum cleaner Type Industrial PACKAGIN...

Страница 8: ...he phonometric test results on this specific model correspond to the following acoustic pressure at 1 meter distance from the vacuum and at 1 60 meter height where there is the noisiest part of the va...

Страница 9: ...o wear or damage Applied directives The following directives apply to the vacuum cleaner described in this manual Ordinary Locations UL 1017 CSA C22 2 N 243 10 Hazardous Locations ISA 12 12 01 2016 CS...

Страница 10: ...LOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ignitible concentrations Do not connect or disconnect when energized ATTENTION Risk of crushing upper limbs whil...

Страница 11: ...these Periodically check the mains power cable to ensure it is not damaged In the event of the cable plugs or couplings being replaced make sure these are protected against water spray and check mech...

Страница 12: ...ied atmosphere area after having disconnected and unplugged the machine and only after 10 minutes from unplugging Non classified atmosphere which means in an area with non potentially explosive atmosp...

Страница 13: ...r and therefore cancel this certification Any alterations to the appliance can only be made by Sinterit Support WARNING NON SPARKING DEFLECTOR The vacuum cleaner is provided with a brassy non sparking...

Страница 14: ...to CSA Std C22 2 68 C22 2 243 C22 2 213 MOD Sinterit INTERTEK Vacuum Cleaner ELECT RATING S N 104 127V 60 Hz 14A 1 1KW 1PH 200218356 MARKING CLASSII DIVISION 2 GROUPS F G AMBIENT TEMP RANGE 0 C T 40...

Страница 15: ...enough to fully protect against all the hazards that could arise during vacuum cleaner operation These will have to be integrated with common sense and the experience of the operator both of which ar...

Страница 16: ...nd injury 1 Set on the castors brake 6 to ensure that the machine is stable 2 Check that the nut of the grounding system 7 on the vacuum cleaner is tightly screwed in 3 Check the components inside the...

Страница 17: ...the sides of the container near the guide pins while locking Perform the container locking operation by means of the levers located on the side USING BOTH HANDS Now you have two options you can use IN...

Страница 18: ...ner safety plate 4 Ensure that the Power cable 8 and the optional extension are in perfect conditions 5 Connect the vacuum cleaner grounding system 7 to a conductive surface 6 Plug the Power cable int...

Страница 19: ...let nozzle by hand Image 11 Incorrect and correct removing the powder from the print chamber 3 The capacity of the collected material in each device should not exceed 3 4 of the container After each c...

Страница 20: ...ot to damage the Power cable 7 Disconnect the internal grounding 16 from the connector 21 to get to the Main Star filter Image 14 5 21 16 Image 13 Release the Release fasteners Image 14 Disconnect the...

Страница 21: ...ical maintenance The Safety Manager has the precise duty of determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there...

Страница 22: ...faults or defects Screws and nuts must always be tightened Clean the Non sparkling deflector 19 inside on a regular basis to prevent dust accumulation inside the Filtering chamber Remove the Motor Hea...

Страница 23: ...et to the Main Star filter Image 16 5 21 16 Image 15 Release the Release fasteners Image 16 Disconnect the internal grounding 16 with connector 21 7 Remove the Main Star filter Watch out for the powde...

Страница 24: ...POSSIBLE FAULT RECOMMENDED REMEDY The vacuum cleaner fails to start No power 1 Check the power mains supply 2 Check the integrity of the plug and Power cable Dust leaking out Perforated Antistatic ho...

Страница 25: ...nly with the product called Sinterit INTERTEK Vacuum Cleaner Due to the constant development of Sinterit s products the information contained in this manual specifications and markings are subject to...

Страница 26: ...malfunction caused by dismantling alterations tuning or other changes of the product by a client or any third party made without written consent of Sinterit damages abnormalities or malfunction cause...

Страница 27: ...e liquid produced vapours or combustible liquid produced vapours are not likely to exist under normal operating conditions Groups F G Material Properties F Carbonaceous Dusts G Non Conductive Dusts fl...

Страница 28: ...SINTERIT Sp z o o ul Nad Drwina 10 bud B3 30 741 Krakow Poland www sinterit com Contact 48 570 967 854...

Отзывы: