Key
Purpose
Color
6
Depth Gnd (shield)
Bare
7
Temp - (shield)
Bare
External alarm
The external alarm can be a small piezo buzzer connected directly, or a horn siren connected
through a relay.
Alarms are configured globally in the system. That is, they can be configured on any one
networked multifunction device or instrument, and be seen, heard, and acknowledged from
all devices. Individual devices can also be configured to not sound their internal buzzer, but
still display the alarm information. For information about configuring alarms, refer to the
Alarms section in the Operator Manual.
For sirens that draw more than 1 Amp, use a relay.
NMEA 2000 backbone
NMEA 2000 Device connection
The NMEA 2000 data port allows the receiving and sharing of a multitude of data from
various sources.
4
3
5
1
2
Unit socket
(male)
1
2
5
4
3
Cable plug (female)
Key
Purpose
Color
1
Shield
Drain