Simrad AP35 Autopilot
54
22083083H
Connecting a solenoid valve
JUNCTION UNIT
POWER PCB
TB1 TB2 TB3 TB4 TB5
TB6
S
o
l. -
M
otor
S
o
l. -
M
otor
So
l. g
nd
TB7
Sol.
Sol.
Sol. gnd
SOLENOID
VALVE
Figure 4-10 Connecting a solenoid valve
4.10
Control unit
Avoid mounting the control unit(s) where it is easily exposed to sunlight, as
this will shorten the lifetime of the display.
Panel mounting
•
Make a panel cut-out of 210x102 mm.
•
Use the supplied fastening device to
fasten the control unit to the panel. See
Figure 4-11
•
Connect the Robnet cables to the control
unit connectors
(See note on next
page).
Figure 4-11 AP35 Panel mounting
Bracket mounting
•
Mount the two bracket halves to the Control unit.
•
Temporarily bolt together the other two halves of the bracket to the two
other halves.
•
Hold the Control unit in place by hand and mark the 4 holes for the fixing
screws on the mounting surface.