Installation
22083083H
51
Main Board terminals
Note !
Terminal "Sys. sel." not in use.
4.9
Drive unit
The relation between drive units, drive unit voltage, input voltage, drive
output and interfacing to steering gear are shown in the table below. The
AP35 system detects whether a reversible motor or a solenoid is connected
and outputs the correct drive signal automatically.
Refer to the connecting diagram for the different drive units on page 53
onwards.
Installation instructions for the drive units are found in the manual for the
individual units.
The maximum drive current capabilities of the J3000X and J300X junction
units are different. Use the table below as reference.
HYDRAULIC PUMPS
RAM
CAPACITY
MODEL MOTOR
VOLTS
JUNCTION
UNIT
MIN
cm
3
(cu. in.)
MAX
cm
3
(cu. in.)
FLOW
RATE AT 10
bar
cm
3
/min
(cu. in/min)
MAX
PRES-
SURE
bar
PWR.
CONSUMP-
TION
RPU80
12V
J3000X
80 (4,9)
250 (15,2)
800 (49)
50
2,5-6 A
RPU160
12V
J300X
160 (9,8)
550 (33,5)
1600 (98)
60
3-10 A
RPU300
12V
J300X-40
290 (17,7) 960 (58,5)
3000 (183)
60
5-25 A
RPU300
24V
J300X
290 (17,7) 960 (58,5)
3000 (183)
60
2,5-12 A
Steering gear interface: Hydraulic plumbing
Содержание AP35
Страница 1: ...INSTRUCTION MANUAL Simrad AP35 Autopilot ...
Страница 10: ...Simrad AP35 Autopilot 8 22083083H This page is intentionally left blank ...
Страница 16: ...Simrad AP35 Autopilot 14 22083083H This page is intentionally left blank ...
Страница 30: ...Simrad AP35 Autopilot 28 22083083H This page is intentionally left blank ...