EA230-K-30 – Functions
Operating Manual
Chain actuator – EA-K-30/xxx-T(-DA)
Chain actuator
– EA230-K-30/xxx(-S)
Page 9
BA_EA(230)-K-30-XXX_EN_12
www.simon-protec.com
Date: 13.02.2019
Issue: 1.2 / 01.2019
5.4 RESET
If necessary, release the connection between the chain
end piece and the top bracket.
Drive the actuator in the OPEN direction and extend the
chain by approx. 10 cm.
Disconnect the actuator from the power supply.
Check the communication cables in the case of actuators
connected in parallel (red / white).
Set both of the DIP switches 1 and 2 to OFF.
Wait for five seconds.
Drive the actuator in the OPEN direction.
The RESET procedure is performed, the orange LED
lights up continuously during this procedure. The
actuator immediately moves in the CLOSED direction
up to the end position, then approx. 5 cm back in
OPEN direction.
The orange LED flashes continuously after performing
the RESET process correctly.
Disconnect the actuator from the power supply again.
Set the DIP switches 1 and 2 to the desired setting.
Wait for five seconds.
Connect the chain end piece to the top bracket again.
Let the actuator perform a teach-in run
(see chapter 5.6 “Performing a teach-in run” on page 9).
5.5 Teach-in run
The actuators detect and store the distance between sash
and frame fully automatically during operation (when the
window is fully closed). The dimensional difference between
wing and frame is called overhang.
This teach-in takes place when the actuator fully closes the
window for the first time after a RESET.
5.6 Performing a teach-in run
Open the actuator slightly and then drive it in the
CLOSED direction and let it cut off in the end position.
If the teach-in process has worked correctly, the
actuator signals this by the flashing of the orange LED
(next to the DIP switches) for approx. 3 seconds.
If the orange LED does not flash as described, a RESET
must initially be performed (see chapter 5.4 “RESET“).
ATTENTION
The chain end piece must not be connected to the bracket
when performing the RESET process.
ATTENTION
The communication cables of the actuators must be
connected to each other during the RESET process in
synchronous mode (red with red and white with white).
ATTENTION
After RESET, e.g. after a stroke setting via the DIP
switches or after installation, you must perform a teach-in
run.