EA-K-30 – Technical Data
Operating Manual
Chain actuator – EA-K-30/xxx-T(-DA)
Chain actuator
– EA230-K-30/xxx(-S)
Page 25
BA_EA(230)-K-30-XXX_EN_12
www.simon-protec.com
Date: 13.02.2019
Issue: 1.2 / 01.2019
Figure 29: Zero volt range at a change in the driving
direction
Table 4: Installation and ambient conditions
Actuator type/version
EA-K-30
Nominal operating temperature
Permissible ambient
temperature range
Temperature stability (smoke
and heat exhaustion)
Protection rating
Area of application
Table 5: Approvals and certificates
Actuator type/version
EA-K-30
CE-compliant
Further approvals
Table 6: Mechanical properties
Actuator type/version
EA-K-30
Nominal pushing force
1
1.
Only under optimum conditions, up to a 600 mm stroke (see
chapter 6.1.11 “Permissible pushing force on the chain” on page 18),
pushing force can be configured via SIMON LINK.
Nominal pulling force
2
2.
Pulling force can be configured via SIMON LINK.
Conditions of loading
Nominal locking force
3
3.
The force may vary depending on the design of the actuator, bracket,
fixing type, window material etc.
Nominal stroke
4
4.
In the case of a stretched chain, e.g. traction relief. The nominal stroke
may deviate by ± 3%, but no more than 20 mm, due to mechanical
damping.
– EA-K-30 / 400-T(-DA)
– EA-K-30 / 600-T(-DA)
– EA-K-30 / 800-T(-DA)
– EA-K-30 / 1000-T(-DA)
– EA-K-30 / 1200-T(-DA)
Stroke speed
5
5.
Based on a 600 mm stroke; deviation ± 5%.
– 300 N
– 200 N
– 100 N
Material – surface
Material – chain
Dimensions (W x H
7
7.
Plus chain exit (7 mm).
x D)
– EA-K-30 / 400-T(-DA)
– EA-K-30 / 600-T(-DA)
– EA-K-30 / 800-T(-DA)
– EA-K-30 / 1000-T(-DA)
– EA-K-30 / 1200-T(-DA)
Weight
8
8.
Information without supply cable and brackets.
– EA-K-30 / 400-T(-DA)
– EA-K-30 / 600-T(-DA)
– EA-K-30 / 800-T(-DA)
– EA-K-30 / 1000-T(-DA)
– EA-K-30 / 1200-T(-DA)
Table 7: Accessories
Actuator type/version
EA-K-30
Mechanical connection to the
actuator medium (chain)
Mechanical connection to the
actuator housing
ATTENTION
Voltage stability/quality: only defined cut-off processes
are permitted (cut-off time of 24 V DC rated voltage to
0 volts in t < 10 ms).
This also applies in particular to switching processes from
a primary (mains operation) to secondary energy source
(backup batteries).
20 °C
from 0 to 75 °C
300 °C
IP 32
Central European
environmental conditions
2000 metres obove sealevel
In accordance with the EMC
Directive 2014 / 30 / EU and the
Low Voltage Directive
2014 / 35 / EU
on request
300 N
300 N
S: +24 V
O: GND
O: +24 V
S: GND
0 V
U
[V] (DC)
t
[ms]
D
500 ms
“OPEN”
“CLOSE”
Opening against the nominal
load /closing with nominal load
support
≤
2000 N
400 mm
600 mm
800 mm
1
000 mm
1
200 mm
N
2
9.7 mm / s
11.1 mm / s
12.5 mm / s
Aluminium E6 / EV1
Coatings
6
are possible in all
RAL and DB colours
Corrosion-resistant,
monostable steel chain, silver
nickel-plated
(a high-grade steel chain is
optionally available)
467 x 37 x 35 mm
564 x 37 x 35 mm
667 x 37 x 35 mm
764 x 37 x 35 mm
867 x 37 x 35 mm
1.30 kg
1.52 kg
1.80 kg
2.02 kg
2.30 kg
6.
Attention: Screws, nuts, discs, sliders and similar individual components
are not coated.
A wide selection of bracket sets
is available. The technical data
only applies in connection with
original accessories!
Actuator type/version
EA-K-30