Electrical
7
For parts or assistance, call Simer Customer Service at
1-800-468-7867 / 1-800-546-7867
Green (Ready) Light
Battery is fully charged and
is on
system is ready.
Green Light is
Battery charge is below 10.9V.
Flashing while the
NOTICE:
Pump may not run
Alarm is beeping
while battery is charging.
Yellow (Charging/
Battery is being charged.
AC Power) Light
is on
Yellow Light
Battery or AC power wires
is Flashing
are not connected.
Red (Pump Cycled)
Pump is running. Normal
Light is on with
back up system operation.
alarm on
System activated by the
float switch.
Red (Pump Cycled)
Pump has run.
light is Flashing while
the Alarm is beeping
Red (Alarm Off)
The alarm is turned off.
Light is on
ALL LIGHTS SECTION
All lights on for
System is resetting.
3 seconds
All lights and
“Test Pump” button is on.
alarm are on
User is testing the pump.
All lights flashing
See Table II,
at a rate of once
Charging Errors.
per second with
the yellow light
and alarm on
All lights flashing
See Table II,
at a rate of once
Charging Errors.
per second with
the alarm on
TABLE III – CONTROL PANEL/LIGHTS
& ALARM SUMMARY
All lights flashing
Blown fuse.
at a rate of once
Battery leads are reversed.
per second
Incorrect battery (not 12V).
with Alarm on
Battery is taking too long to
charge. May need to replace
battery.
Battery in thermal runaway.
Replace battery.
All lights flashing
Battery charge is too low
at a rate of once
(below 8.2V).
The system
per second
will not allow the pump
with the Yellow
to run.
(Charging/AC Power)
light and Alarm on
TABLE II – CHARGING ERRORS
VERTICAL PUMPING DISTANCE (FEET)
0
5
10
15
20
25
30
Flow Rate (gallons per hour)*
1380
1200
1080
840
600
360
60
TABLE IV – CAPACITY RATINGS WITH A 12 VOLT (27M MARINE BATTERY)
* These flow rates were obtained with a constant 12.7 VDC battery source. The average GPH will vary due to a reduction in
output voltage from battery.
Connect the ...
To ...
1. Control Box Panel
the Battery
2. Back-up Pump
the Pump Connection in the
Power Cord
Control Panel
3. Float Switch
the Float Switch Socket in the
Connector
Control Panel
4. Transformer from
the Transformer Socket in the
Wall Outlet
Control Panel
TABLE I – WIRING CONNECTIONS
Содержание Ace-In-The-Hole A5000-01