44
– as soon as the symbols begin to flash, release the buttons
<
and
>
and press the button
y
,
within 3 seconds
– the "Automatic self-calibrating procedure" starts
–
open one or more than one hot water tap
– the values flash on the display:
"100"
(maximum value),
followed by an "intermediate value" and finally
"00"
(minimum
value)
The operator must wait for approximately 15 minutes for the
"self-calibrating procedure" to end and the message "SUMMER
mode"
l
to reappear on the display Once the procedure has
terminated:
– close the taps opened previously and check that the appliance
shuts down.
if there is a fault, the message
"ALL"
will appear on the display,
the fault code (eg.
"06"
- no flame detected) and the message
d
.
m
CAUTION
To restore the start conditions press and hold the
button
y
for more than 3 seconds. This operation
can be performed up to a maximum of 6 times without
the "self-calibrating procedure" being interrupted.
– press the button
Y
once for at least 1 second to select
"WINTER mode"
n
. The value of the heating water
temperature detected at that moment will appear on the
display
– adjust the air thermostat and check that the boiler starts and
operates correctly
– carry out the procedure "
Chimney sweeper function
",
to check the mains gas pressure, detect the combustion
parameters and to measure the combustion efficiency
required by legislation in force.
6.3
Main control panel display and settings
m
CAUTION
We recommend not changing the factory settings so
as not to alter optimal appliance operation. For any
specific support, please contact the
Sime
Technical
Assistance Service.
6.3.1
Settings using the MODE button
From the
“Main screen”
:
Thu 18 Set 2014
Zone
10:30
Menu
Mode
Off
Fig. 100
– Press the
Mode
button to view the
“Function mode”
selection screen. Turn the
encoder to select a mode
(e.g. “Winter”)
Esc
Back
Winter
Off
Summer
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
Fig. 101
– press the
click
encoder to confirm the highlighted
“Mode”
and go to the
“rows”
Esc
Back
Winter
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function OFF
Fig. 102