PRISM THREE-PHASE
Connection power supply
For three-phase variants, connect the power supply according to the diagram:
Name
Thread colour
Connection marking
Phase 1 (see note)
Brown
L1
Phase 2
Black
L2
Phase 3
Grey
L3
Neutral conductor
Blue
N
Earth conductor
Green-yellow
G
Note:
some cars charge using only one phase. For this reason, it is advisable to
connect
the least engaged phase of the system to L1
in order to mitigate the imbalance created
during single-phase charging.