MNS-300EM

Command Manual

Содержание MNS-300EM

Страница 1: ...MNS 300EM Command Manual...

Страница 2: ...Copyright 2019 silex technology Inc All rights reserved WA105840XB...

Страница 3: ...nformation and Customer Services 4 Product Information 4 Customer Support Center 4 2 How to Access Command Console 5 3 Network Commands 7 3 1 SET NW WIRED 8 3 2 SH NW 8 3 3 SET NW MOde 9 3 4 SH NW RAT...

Страница 4: ...5 4 2 Wireless LAN Security Commands 16 4 2 1 SET NW AUTHtype 16 4 2 2 DEL NW CERTS 17 4 2 3 SET NW ENC 17 4 2 4 SET NW KEY 18 4 2 5 SET NW KEYNUM 18 4 2 6 SET NW KEYVAL 18 4 2 7 SET NW WPAPSK 19 4 2...

Страница 5: ...SET NW SSCORGUNIT 26 4 2 23 SET NW SSCSTATE 27 4 2 24 SET NW SSCGEN 27 4 3 Wireless LAN Roaming Control 28 4 3 1 SET NW BGSCAN 28 4 3 2 SET RM 28 4 3 3 SET RM SCAN NORM 29 4 3 4 SET RM THResh CRITica...

Страница 6: ...36 4 6 5 SET IP BOot 36 5 Mesh Commands 37 5 1 SH MEsh PROFILE profile_num 38 5 2 SET MEsh PROFSELect profile_num 39 5 3 SET MEsh profile_num PROFile 39 5 4 SET MEsh profile_num MOde 40 5 5 SET MEsh p...

Страница 7: ...le_num DNSPRImary 46 5 19 SET MEsh profile_num DNSSECondary 46 5 20 SET MEsh profile_num RTMOde 47 5 21 SET MEsh profile_num TXCTL 47 6 Port Commands 49 6 1 Serial Port Commands 50 6 1 1 SH PORT 50 6...

Страница 8: ...DR 58 6 2 4 SET PORT S1 ECCONN 58 6 2 5 SET PORT S1 ECLPORT 59 6 2 6 SET PORT S1 ECNHOST 59 6 2 7 SET PORT S1 ECPORT 60 6 2 8 SET PORT S1 ECRADDR 60 6 2 9 SET PORT S1 ECRPORT 61 6 2 10 SET PORT S1 ECT...

Страница 9: ...Service Commands 71 8 1 SH SERVI 72 8 2 SET SERVI service name BOT 72 8 3 SET SERVI service name EOT 73 8 4 SH SERVI STRings string_num 73 8 5 SET SERVI service name FIlter 74 8 6 SH SERVI FILters 74...

Страница 10: ...mary service_num 80 9 String Commands 81 9 1 SET STRing 82 9 2 CL STRing 82 9 3 SH STRing 83 9 4 SH FILters 84 10 TCP IP Commands 85 10 1 SH IP 86 10 2 SET IP ACcess 87 10 3 SET IP KEepalive 87 10 4 S...

Страница 11: ...H DNS 96 11 2 SET DNS DOMain 96 11 3 SET DNS PRImary 97 11 4 SET DNS SECondary 97 12 NTP Commands 99 12 1 SET NTP SERVER 100 12 2 SH NTP DATE 100 13 GPIO Control Commands 101 13 1 SET GPIO DIR 102 13...

Страница 12: ...12 14 2 SET BT 112 14 3 SET BT PASSkey 113 15 Firmware Update Commands 115 15 1 SET LOAd XModem 116 16 Power Management Commands 117 16 1 SET NW WLIF 118 16 2 SET POWER LEVEL 118 17 Other Commands 119...

Страница 13: ...1 Introduction 1 1 Introduction Thank you for purchasing the Intelligent Module MNS 300EM...

Страница 14: ...etting examples or other content 1 1 Introduction MNS 300EM has the following user s manuals MNS 300EM Command Manual this document This document describes the console commands that can be used on MNS...

Страница 15: ...or trademarks of Microsoft Corporation in the United States and or other countries Wi Fi Wi Fi Protected Access WPA WPA2 are either registered trademarks or trademarks of Wi Fi Alliance Other brand o...

Страница 16: ...ort is available by e mail or telephone for any problems that you may encounter If you cannot find the relevant problem in this manual or on our website or if the corrective procedure does not resolve...

Страница 17: ...om MNS 300EM s Web page Whichever method is used to access the command console the setting method is the same unless otherwise noted Capital letters in the following command explanations are minimum e...

Страница 18: ...6 MNS 300EM Command Manual Blank page...

Страница 19: ...3 Network Commands 7 3 Network Commands This chapter describes the network parameter commands...

Страница 20: ...100Base Half FD10BASE 10Base FULL 10BASE 10Base Half 3 1 SET NW WIRED Shows the current network information SH NW Sample output Local SH NW WiFi Mode STATION WiFi SSID server Regulatory Domain JP Auth...

Страница 21: ...Esh Operates in Mesh Point mode AUto Operates in either Station mode or Mesh Point mode depending on the wireless environment SH NW MODE can show the wireless LAN mode in use Shows the current wireles...

Страница 22: ...number 0 100 to show the relative quality of the wireless link Signal Strength shows RSSI value dBm calculated for the current connection When the Station mode is on and the communication from the Acc...

Страница 23: ...4 Station Commands 11 4 Station Commands This chapter describes the commands to use for the Station mode settings...

Страница 24: ...2 4 GHz frequency bands The factory default value is 802 11A B G N ac SH NW RADio can show the wireless standard in use 4 1 1 SET NW RADio The following describes the general wireless configuration co...

Страница 25: ...put Local SET NW SSID SX ACCESSPOINT_01 Changes the length of time to wait for a wired LAN link before wireless LAN starts in seconds SET NW STARTdelay n Enter the following value for n 1 255 Changes...

Страница 26: ...ate key passphrase not loaded By using the console command up to four wireless profiles can be saved 4 1 6 SH NW PROFILE Shows the wireless LAN networks nearby This displays only the Access Points whi...

Страница 27: ...sen the previous wireless settings will be inherited Since this setting is not saved a value set by PROFACT will be applied after MNS 300EM restarts The factory default value is 1 4 1 7 SET NW PROFCFG...

Страница 28: ...thentication mode TTLS Uses EAP TTLS for EAP authentication mode LEAP Uses LEAP for EAP authentication mode PEAP Uses PEAP for EAP authentication mode EAP FAST Uses EAP FAST for EAP authentication mod...

Страница 29: ...on with TKIP WPA2 AES Performs encryption with AES WPA2 WPA Recognizes AES and TKIP automatically and performs encryption The factory default value is DISable SH NW ENC shows the encryption mode in us...

Страница 30: ...4 2 6 SET NW KEYVAL Chooses the key index of WEP key for the wireless LAN Performs the same configuration as SET NW KEY SET NW KEYNUM n For n specify the key index number of WEP key to use 1 to 4 The...

Страница 31: ...is anonymous SH NW ID shows the current setting value Example Local SET NW ID eapuser01 japan 4 2 8 SET NW ID Sets the Pre Shared Key of WPA SET NW WPAPSK key For key enter a passphrase with 8 63 cha...

Страница 32: ...to force GTC to be used on phase 2 of the PEAP authentication handshake SET NW PEAPGTC ENable DISable Enable Disable mandatory use of GTC ENable Enables mandatory use of GTC DISable Disables mandatory...

Страница 33: ...ory use of MSCHAP ENable Enables mandatory use of MSCHAP DISable Disables mandatory use of MSCHAP This command can be enabled when the wireless LAN authentication method is PEAP and is implemented for...

Страница 34: ...ation method is PEAP and is implemented for protocol tests Usually DISable is selected for a normal operation The factory default value is DISable SH NW PEAPV0 can show the current setting 4 2 12 SET...

Страница 35: ...14 SET NW CACERT Starts updating the client certificate file by using XModem protocol When this command is executed the mode is changed to XMODEM mode SET NW CLCERT 4 2 15 SET NW CLCERT Starts updatin...

Страница 36: ...ty 4 2 17 SET NW SSCCITY The value will be deleted when MNS 300EM restarts Changes the common name of the self signed certificate to be issued SET NW SSCCOMNAME common name string The factory default...

Страница 37: ...SSCCOUNTRY JP Changes the key size bit of the self signed certificate to be issued SET NW SSCKEYSIZE 1024 2048 Choose one of the following values for the key size 1024 Sets the key size to 1024 bits...

Страница 38: ...cal SET NW SSCORGNAME silex technology japan 4 2 21 SET NW SSCORGNAME The value will be deleted when MNS 300EM restarts Changes the organization unit name of the self signed certificate to be issued S...

Страница 39: ...or certificate of MNS 300EM 4 2 24 SET NW SSCGEN When this command is executed the pre configured private key and the self signed certificate will be deleted Changes the state name of the self signed...

Страница 40: ...reless LAN Roaming Control The following describes the commands that change the roaming function settings 4 3 1 SET NW BGSCAN Enables Disables the customized roaming control SET RM ENable DISable ENab...

Страница 41: ...ty exceeds the roaming scan threshold value which represents the wireless link quality The value is enabled only when the customized roaming is set The factory default value is 60 sec Changes the RSSI...

Страница 42: ...DISable Disables the bridge mode The factory default value is DISable 4 4 Wireless Wired Bridge Setting 4 4 1 SET NW BRIDGE Shows the current bridge setting SH NW BRIDGE Sample output Local SH NW BRID...

Страница 43: ...y default value is 00 00 00 00 00 00 SH NW BRCLADDR can show the MAC address in use for the static MAC address mode 4 4 4 SET NW BRCLADDR 4 4 3 SET NW BRACCess Accepts Denies an access to the configur...

Страница 44: ...Enables the static MAC address mode The wireless LAN interface uses the MAC address specified by SET NW BRCLADDR DISable Disables the static MAC address mode MNS 300EM waits a packet on the wired LAN...

Страница 45: ...smart wireless setup using the PBC method SET NW SWSPBC 4 5 Smart Wireless Setup 4 5 1 SET NW SWSPINCODE 4 5 2 SET NW SWSPBC Executes the smart wireless setup using the PBC method SET NW SWSPBC NOWAIT...

Страница 46: ...34 MNS 300EM Command Manual Executes the smart wireless setup using the PIN method SET NW SWSPIN 4 5 4 SET NW SWSPIN...

Страница 47: ...tocol When it fails a link local address is used STATIC A static IP address of MNS 300EM is used The factory default value is AUTO Specifies the IP address to use for Station mode To assign a static I...

Страница 48: ...the option command with the same function The factory default value is 0 0 0 0 4 6 4 SET IP ROuter Changes the number of attempts for automatic IP address configuration using DHCP when Station mode is...

Страница 49: ...5 Mesh Commands 37 5 Mesh Commands This chapter describes the commands that change Mesh parameters MNS 300EM can configure and save up to 5 Mesh profiles...

Страница 50: ...T20 Channel 11 Mesh group SX MESH NET Maximum hops No Limit Mesh route refresh Enabled Mesh route refresh method LIGHT Mesh route refresh Interval 3600 Mesh power save Enabled Boot method DHCP IP addr...

Страница 51: ...etting Enables Disables the Mesh profile of the specified number profile_num when Auto mode is on SET MEsh profile_num PROFile ENable DISable ENable Enables the specified Mesh profile DISable Disables...

Страница 52: ...lt value is HT20 SH MEsh profile_num CHWidth can show the current value 5 5 SET MEsh profile_num CHWidth Sets the wireless LAN mode to Mesh profile of the specified number profile_num SET MEsh profile...

Страница 53: ...1 SH MEsh profile_num CHannel can show the current value Sets the Mesh group name to Mesh profile of the specified number profile_num SET MEsh profile_num GRoup name Specify the Mesh group name for na...

Страница 54: ...KEY can show the current value Example Local SET MESH 1 KEY mesh key01 Sets the maximum number of hops to Mesh profile of the specified number profile_num SET MEsh profile_num HOP n Enter the followi...

Страница 55: ...y default value is ENable SH MEsh profile_num REF can show the current value 5 10 SET MEsh profile_num REFresh Sets the route refresh method for Mesh profile of the specified number profile_num SET ME...

Страница 56: ...lt value is 3600 sec SH MEsh profile_num REFInterval can show the current value Enables Disables the power saving function for Mesh profile of the specified number profile_num SET MEsh profile_num POW...

Страница 57: ...ile of the specified number profile_num SET MEsh profile_num IPADdress aa bb cc dd Enter the IP address for aa bb cc dd To assign a static IP address to MNS 300EM use this command to specify the IP ad...

Страница 58: ...er profile_ num SET MEsh profile_num DNSPRImary aa bb cc dd Enter the primary DNS server s IP address for aa bb cc dd The factory default value is 0 0 0 0 5 17 SET MEsh profile_num IPROuter 5 18 SET M...

Страница 59: ...e stable type for the route switching mode The factory default value is STAble 5 20 SET MEsh profile_num RTMOde Enables Disables the transmission control function for Mesh profile of the specified num...

Страница 60: ...48 MNS 300EM Command Manual...

Страница 61: ...6 Port Commands 49 6 Port Commands This chapter describes the commands for serial port settings and Ecable mode...

Страница 62: ...annot be used for that port such note is described 6 1 Serial Port Commands 6 1 1 SH PORT Shows the serial port setting SH PORT Sample output Local SH PORT Port Q Size Type Attributes S1 0 serial 1152...

Страница 63: ...the trap mode and the string defined by this command is entered on the serial port the serial port will enter into the console mode In the console mode the MNS 300EM s settings can be configured from...

Страница 64: ...essive escape characters 6 1 5 SH PORT S1 CONSTR Shows the console mode string of MNS 300EM SH PORT S1 CONSTR When non printable characters are contained in the string x is added at the beginning of t...

Страница 65: ...set HI when there is an active network link and Low when the network link finishes HI The DTR signal is set HI LOW The DTR signal is set Low When GPIO2 is not set for a special function this value wi...

Страница 66: ...ill be deleted 6 1 9 SET PORT S1 LATency Sets the latency of the serial port msec SET PORT S1 LATency ms Enter the latency for ms When a number other than 0 is entered the driver will wait for the spe...

Страница 67: ...y parity Choose one of the followings for parity NOne EVen ODd The factory default value is NOne Sets the baud rate of the serial port SET PORT S1 SPeed baudrate Choose one of the followings for baudr...

Страница 68: ...1 or 2 as the stop bit The factory default value is 1 6 1 12 SH PORT S1 STAtus Shows the serial port status SH PORT S1 STAtus Sample output Local SH PORT S1 STAtus Port S1 status On line Serial Devic...

Страница 69: ...Disables E Cable SET PORT S1 ECABLE ENable DISable ENable Enables E Cable DISable Disables E Cable The factory default value is DISable 6 2 2 SH PORT S1 ECABLE Shows the current E Cable setting SH PO...

Страница 70: ...al for connection retry in case TCP connection is lost or cannot be established This setting is valid for TCP mode only SET PORT S1 ECCONN n Specify the interval of connection retry for n The configur...

Страница 71: ...epted and passed to the I O port When the primary and all secondary addresses are 0 0 0 0 data from any host will be accepted When 0 is set to the port number data reception will be disabled The facto...

Страница 72: ...the primary secondary IP address of E Cable destination This setting is valid for UDP mode only SET PORT S1 ECRADDR index aa bb cc dd index When the index value is set to 0 the primary address is set...

Страница 73: ...e n is the value configured by SET PORT S1 ECNHOST When n is 1 only the primary port can be set port Specifies the UDP port number for E Cable destination When 0 is given no data will be sent The fact...

Страница 74: ...S 300EM Command Manual 6 2 11 SET PORT S1 ECUDP Enables Disables the UDP mode SET PORT S1 ECUDP ENable DISable ENable Enables the UDP mode DISable Disables the UDP mode The factory default value is DI...

Страница 75: ...7 Server Commands 63 7 Server Commands This chapter describes the commands for the server information of MNS 300EM...

Страница 76: ...SH SERIAL Serial number is 9047595 7 1 SH SERIAL Shows the server information SH SERVEr Sample output Local SH SERVEr Silex MNS 300EM Serial 2000560 Address 84 25 3F 01 29 F3 Name SDS1E86B0 Number 0...

Страница 77: ...es 0 Multicast Bytes Rcv d N A Receive Failure Reasons N A Multicast Bytes Sent N A Unrecognized Destination N A Multicast Frames Rcv d N A Data Overrun N A Multicast Frames Sent N A User Buffer Unava...

Страница 78: ...his command only shows the firmware version string that does not include the information shown by SH VERsion 7 5 SH SERVEr FWVER Shows the server model name SH SERVEr MODEL Sample output Local SH SERV...

Страница 79: ...for the peripheral 0 connections have been made 0 data files have been printed 0 data bytes have been printed 0 control files have been received 0 print job commands have been received 7 8 SH SERVEr...

Страница 80: ...utput Local SH SERVEr QUE Port S1 status On line Type Source The queue is empty 7 9 SH SERVEr QUEue Shows the SNMP protocol setting enabled disabled SH SNMP Sample output Local SH SNMP SNMP is Enabled...

Страница 81: ...ring 7 13 SET SNMP LOCation Specifies the sysContact string for SNMP SET SNMP CONtact string Enter the character string of the contact for string The factory default value is a NULL string 7 11 SET SN...

Страница 82: ...ilex MNS 300EM Firmware Ver 1 00 20xx xx xx Boot Ver 1 2 64Mbit Flash Protocols supported SNMP TCP IP DHCP 7 15 SH VErsion Specifies the community name for SET command processing of SNMP SET SNMP SETC...

Страница 83: ...8 Service Commands 71 8 Service Commands MNS 300EM s serial port is associated with the logical I O service This chapter describes commands for the I O service...

Страница 84: ...rvice of I O port 8 1 SH SERVI Sets the index number of the beginning of transmission BOT string for the specified service SET SERVI service name BOT n service name Specifies the service name n Specif...

Страница 85: ...x number is sent at the end of output The factory default value is a NULL string Shows the BOT and EOT strings to use for the service SH SERVI STRings string_num When string_num is specified Shows the...

Страница 86: ...1 SDS1E86B0_S1_A 0 No Filter 2 SDS1E86B0_S1_B 0 No Filter 8 6 SH SERVI FILters Sets the filter index of the service SET SERVI service name FIlter n service name Specifies the service name n Specifies...

Страница 87: ...lter default value CRLF carriage return line feed will be set The factory default value is 0 8 8 SET SERVI service name FRS Specifies the index number of match string for Filter 1 string replacement f...

Страница 88: ...vice name NAme Enables Disables the IP distributed jobs LPD Raw TCP etc SET SERVI service name IP ENable DISable service name Specifies the service name ENable Enables jobs distributed via IP DISable...

Страница 89: ...t name to be associated The factory default value is S1 8 11 SET SERVI service name POrt Specifies the priority for services when multiple services send data at the same time The higher priority data...

Страница 90: ...sent to the port DISable The job is denied The factory default value is DISable 8 14 SET SERVI service name QUEue Shows the priority for the specified services SH SERVI PRI service_num For service_nu...

Страница 91: ...ode DISable Disables the receive only mode The factory default value is DISable 8 15 SET SERVI service name RECeive Specifies the TCP port number for Raw TCP port of the service SET SERVI service name...

Страница 92: ...of the service to show the setting When no number is provided settings of all services will be shown Sample output Local SH SERVI SUMARY 2 Service Port FIL BOT EOT DEL OPT PROT 2 SDS40CB90_S1_B S1 0 1...

Страница 93: ...9 String Commands 81 9 String Commands This chapter describes the commands that can set the strings to use for services and service filters...

Страница 94: ...ecified When FF is added to the beginning of string the registered index number of the string can be specified The string of the specified index number will be used for the service Sample output SET S...

Страница 95: ...string_num When string_num is provided Shows the string of string_num and the extended information When string_num is not provided Shows all the strings without the extended information Sample output...

Страница 96: ...Command Manual Shows the filter that can be used to modify the job stream SH FILters Sample output Local SH FIL Filter 0 No Filter 1 Text Substitution 3 Text to PostScript 4 PostScript Tagged Binary 9...

Страница 97: ...10 TCP IP Commands 85 10 TCP IP Commands This chapter describes the commands for TCP IP function settings...

Страница 98: ...put Local SH IP IP is enabled Boot method DHCP IP address 192 168 5 40 192 168 5 235 Subnet Mask 255 255 255 0 255 255 255 0 IP gateway 192 168 5 1 0 0 0 0 Boot tries 3 Timeout 1 min Keepalive 1 min S...

Страница 99: ...an IP address range from the IP address list when it is found on the list ALL Clears the IP address list and allows access of all hosts aa bb cc dd and ee ff gg hh Specifies the IP address range The...

Страница 100: ...DISable 10 5 SET IP TFTP Enables Disables the NTP protocol SET IP NTP ENable DISable ENable Enables the NTP protocol DISable Disables the NTP protocol The factory default value is ENable 10 6 SET IP...

Страница 101: ...ables the LPD protocol SET IP LPD ENable DISable ENable Enables the LPD protocol DISable Disables the LPD protocol The factory default value is ENable 10 8 SET IP LPD Enables Disables the Silex Techno...

Страница 102: ...closed and the port will be released for new connections When SET IP FTIme is ENable the value will be configured in the unit of seconds Otherwise the unit of minutes will be applied The factory defau...

Страница 103: ...imeout is measured in minutes The factory default value is DISable 10 12 SET IP FTIme Enables Disables reprinting an uncompleted print job over LPD protocol SET IP REtry ENable DISable ENable Enables...

Страница 104: ...show the current setting value 10 15 SET IP WIndow Specifies the user defined IP status string SET IP STATus status string This command can define any string If a string is defined it will be returned...

Страница 105: ...mmands 93 Enables Disables the banner printing on LPD SET IP BAnner ENable DISable ENable Enables the banner printing DISable Disables the banner printing The factory default value is DISable 10 16 SE...

Страница 106: ...94 MNS 300EM Command Manual Blank page...

Страница 107: ...11 DNS Commands 95 11 DNS Commands This chapter describes the commands for DNS function settings...

Страница 108: ...ain name Primary DNS server 0 0 0 0 Secondary DNS server 0 0 0 0 11 1 SH DNS Specifies the domain name required by the DNS function SET DNS DOMain domain name Enter 1 32 alphanumeric characters for do...

Страница 109: ...he IP address of secondary DNS server for aa bb cc dd The factory default value is 0 0 0 0 11 4 SET DNS SECondary Specifies the IP address of primary DNS server SET DNS PRImary aa bb cc dd Enter the I...

Страница 110: ...98 MNS 300EM Command Manual Blank page...

Страница 111: ...12 NTP Commands 99 12 NTP Commands This chapter describes the commands for NTP settings...

Страница 112: ...p to 48 characters When no value is given to server the factory default value is used The factory default value is pool ntp org SH NTP SERVER can show the current value Example Local SET NTP SERVER se...

Страница 113: ...Control Commands This chapter describes the commands for GPIO signal settings MNS 300EM has 11 GPIO signals and number 0 10 is assigned for each For details on the GPIO signal definitions and functio...

Страница 114: ...tion to output gpio number Specifies the number of GPIO signal to set 0 10 This command specifies the direction input output for each GPIO signal When the special function mode is on this setting is i...

Страница 115: ...Control Commands 103 Shows the GPIO signal direction settings SH GPIO DIR Sample output Local SH GPIO DIR GPIO Direction 0 SPCL 1 SPCL 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 13 2 SH G...

Страница 116: ...en 1 is given for each bit of bit mask the GPIO signals are set to be an output and when 0 is given they are set to be an input For example when 080 hex is entered for bit mask GPIO7 is set to be an o...

Страница 117: ...ial function gpio number Specifies the number of GPIO signal to set 0 10 This command enables or disables the special function defined for individual GPIO signal For details on the special function as...

Страница 118: ...ls SH GPIO SPECial Sample output Local SH GPIO SPECIAL GPIO Special Functions GPIO 0 is special GPIO 1 is special GPIO 2 is normal GPIO 3 is normal GPIO 4 is normal GPIO 5 is normal GPIO 6 is normal G...

Страница 119: ...PIO 0 When 1 is given for each bit of bit mask the special function of GPIO signals is enabled and when 0 is given it is disabled For example when 080 hex is entered for bit mask the special function...

Страница 120: ...PIO 2 GPIO 1 GPIO 0 When the GPIO signal is set to be an output the value specified by bit mask is applied and when it is set to be an input the value is not applied Also when the special function of...

Страница 121: ...e current input output values of GPIO signals SH GPIO DATA Sample output Local sh gpio data GPIO Data In GPIO 0 1 GPIO 1 0 GPIO Data Out GPIO 2 0 GPIO 3 0 GPIO 4 0 GPIO 5 0 GPIO 6 0 GPIO 7 0 GPIO 8 0...

Страница 122: ...110 MNS 300EM Command Manual Blank page...

Страница 123: ...14 Bluetooth commands 111 14 Bluetooth Commands This chapter describes the commands for Bluetooth functions...

Страница 124: ...Sample output Local SH BT BT configuration list Bluetooth Enabled Passkey 000000 14 1 SH BT Enables Disables the Bluetooth function SET BT ENable DISable ENable Enables the Bluetooth function DISable...

Страница 125: ...Specifies the pass key used for Bluetooth pairing SET BT PASSkey n n 0 999999 default 0 Enter the following value in n 0 999999 Specifies the pass key for Bluetooth pairing The factory default value...

Страница 126: ...114 MNS 300EM Command Manual Blank page...

Страница 127: ...15 Firmware Update Commands 115 15 Firmware Update Commands This chapter describes the command for firmware update...

Страница 128: ...ET LOAd XModem Sample output Local SET LOAd XModem You may begin your XModem transfer now The firmware update file MNS 300EM bin is sent to MNS 300EM after the above message is shown When the file is...

Страница 129: ...16 Power Management Commands 117 16 Power Management Commands This chapter describes the commands for the wireless module s power operation...

Страница 130: ...nd stops emitting radio waves The factory default value is UP 16 1 SET NW WLIF Changes the power level of MNS 300EM SET POWER LEVEL n Enter one of the following values for port 0 High power level The...

Страница 131: ...17 Other Commands 119 17 Other Commands This chapter describes other commands...

Страница 132: ...mmand Enter only HElp or enter a command after HElp to see the information Sample output Local HE EXIT D Exit program HElp Information on available commands INitialize Reset unit CLear PUrge DELete Re...

Страница 133: ...memory SAVE 17 6 SAVE Starts a soft reset when the EXIT command is executed INIT 17 4 INIT Changes the password to access MNS 300EM SET PAssword password Enter 1 8 alphanumeric characters for password...

Страница 134: ...122 MNS 300EM Command Manual Blank page...