7.13
Replacing the microswitch
ATTENTION: remove the mains plug.
1) Access the bottom compartment (ch.7.4).
2) Disconnect the connectors (Z1) from the microswitch.
3) Loosen the fixing nut and remove the micro-switch.
4) Install the new microswitch and regulate by means of the fixing nut;
-
with carriage back: micro-switch off (Fig. 64)
-
with carriage forward: micro-switch on (Fig. 65)
5)
Re-connect the connectors to the micro-switch.
6) Replace the bottom plate and secure with the 6 screws (Fig. 39).
7)
Replace the machine on the workbench.
Fig. 63
Fig. 64 - micro-switch OFF
Fig. 65 - micro-switch ON