Clamp knobs
The clamps are locked by two anatomical knobs (F), which ensure perfect grip on the keys with only slight locking
pressure.
Gauges
Next to the clamps there is a rod with two gauge tabs (H) to control key alignment.
Brush
The brush (P) is used to eliminate burrs from the cuts and is made of non-abrasive material. To activate the brush,
turn the push-button (N) on the left-hand side of the machine.
2.1 Further Risks
ATTENTION: there are residual hazards in the cutting
zone (A) where the cutter is located. Carefully observe
the warnings in the manual..
ATTENTION: DANGEROUS MOBILE PARTS. Keep all
body parts away from moving parts
ATTENTION: the cutter is in motion when the button
(N) is pressed to activate the brush and remove burrs
after key cutting.
Fig. 6
2.2 Technical Data
Power supply:
230V - 50/60Hz
Maximum absorbed power:
230V: 390 Watt 2A
Cutter motor:
single phase and speed
230V-50/60Hz: 1350/1620 rpm.0,18Kw
Movements:
by gear on rectified carriage
Clamps:
rotating with four sides, high precision
Cutter:
HSS Super Rapid Steel - coated
Runs (maximum length of cuts):
43 mm
Dimensions
:
width: 330 mm (with max. lever encumbrance 510 mm)
depth: 430 mm - height: 270 mm
Mass:
Kg. 19
Noise level:
sound pressure Lp(A) = 99,9 dB (brass keys)
100,2 dB (steel keys)
Note: in some working conditions, noise can exceed 90 dB (A).
It is advisable to use suitable otoprotectors.