![Silca REKORD PRO d-12 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/silca/rekord-pro-d-12/rekord-pro-d-12_operating-manual_1270928030.webp)
7.6
Replacing lamp set/lamp protection
• Lamp set
ATTENTION: remove the mains plug
.
1) Remove the two pads (Fig. 43)).
2) Loosen the 3 screws (M1) and remove the top cover (M) (Fig. 34).
3) Access the lower compartment (chap.7.4).
4) Loosen the 2 low voltage connector screws (Q1) and remove them (Fig. 41).
5)
Position the machine upright again.
6) Loosen the 2 lamp fixing screws (L1) and remove (Fig. 43).
7) Replace the top cover and secure with the 3 screws (M1).
8)
Turn the machine over onto its back.
9) Connect the 2 connectors in the low voltage supply outlet seat and secure with the 2 screws (Q1) (Fig. 41.
10)
Replace the bottom plate and secure with the 6 screws (Fig. 39.
11)
Return the machine to its upright position.
• Lamp protection
ATTENTION: remove the mains plug
.
1)
Remove the two pads
(Fig. 34)
.
2) Loosen the 3 screws (M1) and remove the top cover (M) (Fig. 34).
3) Loosen the 2 lamp fixing screws (L1) and remove (Fig. 43).
4) Loosen the 2 screws (L2) in order to remove the lamp protection (L3) (Fig. 44).
5) Fit the new protection and secure with the 2 screws (L2).
6) Replace the lamp unit and secure with the 2 screws (L1) making sure the wiring is positioned to-wards the bottom
of the machine.
7) Replace the top cover and secure with the 3 screws (M1).
Fig. 43
Fig. 44
Operating manual
REKORD PRO d-12
Copyright Silca S.p.A 2022
26