![Siko MSAC501 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/siko/msac501/msac501_additional-to-the-original-installation-instructions_1270550032.webp)
MSAC501-S(RS485)
Service mode (RS485 mode) English
MSAC501-S(RS485) · Date
01.07.2019 · Art.
No.
88115 · Mod.
status
168/19
32
Command
Length Reply
Description
X
1
0xyy>
Ê
(6byte)
Sys register output in hex representation
(yy = hex representation of bit 0 ... 7)
Bit0 = sensor/band gap error 0: Gap okay;
1: Sensor/band distance too large
Bit1 = plausibility error absolute value
Bit2 = speed check
Bit3 = not used
Bit4 = adjustment 0: normal operation; 1:
adjustment running
Bit5 = verify error in EEPROM 0: no error;
1: Wrong values in EEPROM
Bit6 = CS error in EEPROM 0: no error; 1:
CS error occurred
Bit7 = error when reading/writing the
EEPROM 0: no error; 1: error
Yx
2
0xyy>
Ê
(6byte)
Output of flag registers 0, 1 and 2: (yy =
hex representation of bit 0 ... 7)
Flag-Register 0:
Bit0 = Unused, always 0
Bit1 = counting direction 0: Up; 1: Down
Bit2 = not used
Bit3 = Interpolator module 0: not availa-
ble; 1: available
Bit4 = Position value filtering 0: OFF; 1:
ON
Bit 6 Bit 5 Absolute resolution
0
0
10 Bit (factory setting)
0
1
9 Bit
1
0
8 Bit
1
1
7 Bit
Bit7 = Unused, always 0