![Siko MSAC501 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/siko/msac501/msac501_additional-to-the-original-installation-instructions_1270550023.webp)
MSAC501-S(RS485)
SIKONETZ3 interface English
MSAC501-S(RS485) · Date
01.07.2019 · Art.
No.
88115 · Mod.
status
168/19
23
Hex TX RX S P R Function
2D
6
6
S P -
Write counting direction
Data byte Low = 00h: ascending numerical values
with sensor movement towards the connector,
Data byte Low = 01h: descending numerical values
with sensor movement towards the connector
The state of the Middle and High data bytes is not
relevant.
32
3
3
-
-
-
Program mode "ON"
Programming mode must be "On" in order to enable
the use of the 28h, 2Dh and 48h commands!
33
3
3
-
-
-
Program mode "OFF"
3A
3
6
-
-
-
Read system status (Assignment of status bits: see
"Meaning of the status bits in the system status")
3B
3
3
-
-
-
Delete system status
System status bytes 2 = data byte Middle and 3 = data
byte High are set to 0
48
3
3
S P -
Reset: position value is set to 0 + calibration value
4F
3
3
-
-
R Freeze position value
Position value is frozen. This state is reset by reading
the position value. With this feature it is possible to
read out several devices synchronized.
Meaning of the status bits in the system status
Data byte low:
Bit0: always 0
Bit1: always 0
Bit2: always 0
Bit3: position value frozen
Bit4: always 0
Bit5: programming state
Bit6: always 0
Bit7: always 0
Data byte middle:
Bit8: always 0
Bit9: error 02 occurred
Bit10: error 03 occurred
Bit11: error 05 occurred
Содержание MSAC501