MSAC501-S(RS485)
Service mode (RS485 mode) English
MSAC501-S(RS485) · Date
01.07.2019 · Art.
No.
88115 · Mod.
status
168/19
30
Command
Length Reply
Description
Ix
2
Depending on
the set param-
ters
Output of the set incremental scaling (x =
0) or the pulse interval (x = 1).
If x = 0:
- 10Bit_Ink>
Ê
(factory setting)
- 9Bit_Ink>
Ê
- 8Bit_Ink>
Ê
- 7Bit_Ink>
Ê
Note:
The incremental resolution corre-
sponds to the four-fold of the set scal-
ing (example: 10Bit scaling -> resolution
= 4096).
If x = 1:
- Pulse interval 0.2µs>
Ê
- Pulse interval 0.5µs>
Ê
- Pulse interval 1µs>
Ê
- Pulse interval 2.5µs>
Ê
- Pulse interval 4µs>
Ê
- Pulse interval 8µs>
Ê
- Pulse interval 16µs>
Ê
- Pulse interval 32µs>
Ê
- Pulse interval 66µs>
Ê
Jxy
3
>
Ê
(2byte)
Input of the desired incremental scaling
(x = 0) and the pulse interval (x = 1):
If x = 0:
y = 0: 10 Bit_Ink
y = 1: 9 Bit_Ink
y = 2: 8 Bit_Ink
y = 3: 7 Bit_Ink
If x = 1:
y = 0: Pulse interval 0.2 µs
y = 1: Pulse interval 0.5 µs
y = 2: Pulse interval 1 µs
y = 3: Pulse interval 2.5 µs
y = 4: Pulse interval 4 µs
y = 5: Pulse interval 8 µs
y = 6: Pulse interval 16 µs
y = 7: Pulse interval 32 µs
y = 8: Pulse interval 66 µs
The parameters set are stored in the non-
volatile memory.
K
1
no
Sensor restart.
L
1
>
Ê
(2byte)
Setting the position value to the calibra-
tion value.