5.
FORMING THE STRAP JOINT
Press the sealer lever (#2) down
and release (Do not hold sealer
lever down during the entire
sealing cycle). Air will be then
routed to the second air motor
enabling the sealer mechanism to
punch the strap and cut-off the
TOP STRAP. The sealer
mechanism will disengage from
the strap leaving the cut off end of
the strap clamped under the
feedwheel.
NOTES:
!
Holding the sealing lever down will result in the tool attempting continuous sealing cycles.
!
Never activate tension lever with a single strap under the feedwheel as this will cause the tool
to lock up.
!
If the tool does not fully cycle in making the strap joint, it cannot be removed from the strap.
!
If the tool does not complete the strap cycle, check for proper operating pressure of 70-90 psi.
(4.8-6.2 Bar).
!
If the tool stalls using proper air pressure, disconnect air supply and cut strap off of package.
Remove the side covers and inspect the tool for broken parts.
6.
TOOL REMOVAL & JOINT
INSPECTION
Squeeze the tension motor and the
stationary handle together to
release the cut off strap end.
Swing the SLP tool out from under
the strap. To make sure the tool
has properly formed a joint,
closely inspect the strap. Refer to
Sealing Operation on the following
page for details regarding an
acceptably formed joint.
For Parts & Service 1-877-862-6699
WWW.TRADITIONALTOOL.COM