#4 SYMPTOM: Strap tension is too low or too high.
CAUSE
REMEDY
Strap tension incorrectly set.
Adjust strap tension per instructions on page
13 of this manual.
#5 SYMPTOM: Tool does not complete sealing cycle.
CAUSE
REMEDY
1.
Improper strap being used.
2.
Worn or broken dies and/or punch.
3.
Insufficient air pressure.
1.
Check that waxed strapping of the
correct width and thickness is being
used.
2.
Inspect dies and punch replace as
required.
3.
Check that air supply available is at
least 60 psi (4.0 bar).
#6 SYMPTOM: Strap does not cut after sealing cycle.
CAUSE
REMEDY
1.
Improper cutter clearance.
2.
Worn or broken cutter blade.
1.
Inspect strap for proper cut-off, adjust
cutter clearance if necessary.
2.
Inspect cutter blade, replace or rotate
as required.
#7 SYMPTOM: Bottom strap breaks during sealing.
CAUSE
REMEDY
1.
Improper cutter clearance. (Strap breaks
at cutter.)
2.
Tension set too high. (Strap breaks at
the joint area.)
3.
Worn or broken dies and/or punch.
(Strap breaks at the joint area.)
4.
Package has sharp corners. (Strap
breaks at package corner.)
1.
Inspect strap for proper cut-off, adjust
cutter clearance if necessary.
2.
Reduce strap tension.
3.
Inspect dies and punch replace as
required.
4.
Lower strap tension or use package
corner protectors.
#8 SYMPTOM: Tool cannot be removed from strap after completion of strap cycle.
CAUSE
REMEDY
1.
Punches & Dies worn.
2.
Sealer motor running too fast.
1.
Inspect parts, replace punches and dies
as needed.
2.
See Sealer Motor adjustment on page
15 of this manual.
For Parts & Service 1-877-862-6699