Sigineer Power MS6048D Скачать руководство пользователя страница 8

                                                                                                                          www.sigineer.com 

 

6

 

*Stackable up to 6 pcs 
* AC Coupling with Grid Tie Inverters 
*Battery Polarity Reverse Protection 
*Smart remote monitor with WIFI or GPRS Module 
*Remote LCD Panel with Adjustable Parameters 
*80A MPPT Solar Charger 
*Maximum THD: 3% at nominal battery voltage 
*Powerful 4-stage power factor corrected battery charger 
*High surge output capability, 200% peak load for 5 seconds 
*Low quiescent current, low power ‘Power Saver Mode’ to conserve energy 
*Equalization Charging 
*20ms transfer time from AC to battery for the continuous load operation 
*Thermally controlled variable speed fan for more efficient cooling 
*Extensive protections against various harsh situations 
*Solar Priority or SBU developed for renewable energy systems 
*Parallel operation up to 6 units, capable of forming three phase or split phase output

 

 

2.4 Electrical Performance 

2.4.1 DC to AC Invert 

 

Overload Capacity 

The MS6048D inverter/charger has different overload capacities, making it ideal to handle demanding loads. 
1 For 110%<Load<150%, Fault (Power off) after 10 seconds. 
2 For 150%<Load≤200%, Fault (Power off) after the 5 seconds. 
 

Caution: 

After the inverter is switched on, it takes a finite time for it to self diagnose and get ready to deliver full 
power. Hence, the user should always switch on the load(s) after a few seconds of switching on the inverter 
to avoid switching on the load before the inverter is powered on. This may prematurely trigger the overload 
protection. When a load is switched on, it may require a higher initial power surge to start. If multiple loads 
are being powered, they should be switched on one by one so that the inverter is not overloaded by the 
higher starting surge. 
 

2.4.2 AC & MPPT Charger 

The V Series pure sine wave inverter/charger is equipped with an active PFC (Power Factor Corrected) 
multistage battery charger. The PFC feature is used to control the amount of power used to charge the 
batteries in order to obtain a power factor as close as possible to 1. 
The V Series pure sine wave inverter/charger has a very rapid charge current available, and the max charge 
current can be adjusted from 10% to 100% in small increments on the LCD of the inverter. This will be 
helpful if this powerful charger applies charging on a small capacity battery bank.   
The max charging current decreases according to the input AC voltage.   
There are three main charging stages: 

Bulk Charging: 

This is the initial stage of charging. While Bulk Charging, the charger supplies the battery 

with controlled constant current. The charger will remain in Bulk charge until the Absorption charge voltage 
(determined by the Battery Type selection) is achieved.   

Содержание MS6048D

Страница 1: ...tackable Solar Inverter Charger with AC Coupling User s Manual For Model MS6048D Version 2 1 PN MS604820220608 Manufacturer Information Sigineer Power Limited Email info sigineer com TEL 86 769 828176...

Страница 2: ...Bypass Control With Timer 28 2 4 14 Automatic Neutral to Ground Bonding 28 2 4 15 Lithium Battery Wakeup 28 2 4 16 Other Features 28 3 Installation 29 3 1 Location 29 3 2 Unpacking and Inspection 29 3...

Страница 3: ...ce around the inverter for air flow Make sure that the air can circulate freely around the unit A minimum air flow of 145CFM is required 1 1 3 To avoid a risk of fire and electronic shock Make sure th...

Страница 4: ...njury and damage NEVER charge a frozen battery 1 2 6 Don t install the inverter near batteries the inverter may heat battery electrolyte and cause corrosive fumes to vent and damage corrode nearby ele...

Страница 5: ...t can create an AC coupled system with grid tie inverters by paralleling the AC outputs to the loads This allows the users to easily retrofit the on grid system without removing the grid inverter The...

Страница 6: ...www sigineer com 4...

Страница 7: ...Parallel Communication Ports 10 Current Sharing Ports 11 AC Output 12 AC Input Terminal 13 USB Port connects to computer 14 AGS Dry Contact 15 Wi Fi GPRS Port 16 Battery Terminals 17 ON OFF Power Swit...

Страница 8: ...full power Hence the user should always switch on the load s after a few seconds of switching on the inverter to avoid switching on the load before the inverter is powered on This may prematurely tri...

Страница 9: ...charger will drastically reduce the charging current to zero once float voltage is reached The charging capacity will go to peak in around 3 seconds this may probably cause a generator to drop freque...

Страница 10: ...ualization voltage point the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage If battery voltage is still lower than battery equaliz...

Страница 11: ...e 2 4 4 Power Saver There are two working statuses for the inverters Power On and Power Off When power switch is in the Unit Off position the inverter is powered off When power switch is turned to Pow...

Страница 12: ...inverter may be programmed to remain operating at full output voltage 2 4 5 Protections The MS Series inverter charger is equipped with extensive protections against various harsh situations faults T...

Страница 13: ...itor the inverter via both WiFi and USB port the RMT WiFi module can be connected via a short extension cable 2 4 7 LCD Specification Setup Press the On Off switch to turn on the unit The operation an...

Страница 14: ...of load power percentage of load Indicate overload happened Indicate short circuit happened Battery Information Indicate battery level by 0 24 25 49 50 74 and 75 100 in battery mode and charging stat...

Страница 15: ...ity power Indicates the utility charger circuit is working Indicates the DC AC inverter circuit is working These three signs indicate the output priority SOL FIRST indicates solar first BAT FIRST indi...

Страница 16: ...olar power is lost the utility will have higher priority than battery This mode can be regarded as SUB Solar Utility Battery In this mode the inverter will transfer between DC and AC as per the settin...

Страница 17: ...r is connected to a generator the generator should be more than twice the inverter nominal power Program 04 Power Saving Mode Enable Disable 04 SdS When the power saver mode is disabled the inverter w...

Страница 18: ...Lithium This setting only works when inverter communicates with lithium battery BMS built with the same protocol The program is set to LI the LCD will show a hidden program of 36 about BMS protocol t...

Страница 19: ...m 14 Charge Power Source Priority 14 CSO Solar Priority Solar energy will charge battery as the first priority Utility will charge battery only when solar energy is not available lost 14 SNU Solar and...

Страница 20: ...battery without AC output 3 If PV energy battery power and utility are all available inverter will transfer to line mode and provide output power to loads and charge the battery at the same time When...

Страница 21: ...d in program 05 this program can be set up The Equalization is banned for AGM batteries Program 44 Battery Equalization Voltage Model Default Value Resettable Range MS6048D 58 4V 48 58 4V Program 45 B...

Страница 22: ...m 00 to 23 and the lower two digits represent the time when inverter end to power the load setting range from 00 to 23 eg 2320 represents the time allows inverter to power the load is from 23 00 to th...

Страница 23: ...s The default value is 4 for 48V model and 2 for 24Vdc model 11 Maximum Utility Charging Current 10A to Max default 30A 12 DC to AC Transfer Voltage Default 46 0V 44 0V 51 2V resettable 12 DC to AC Tr...

Страница 24: ...Without BMS communication 21 Low Battery Cut Off Voltage With BMS communication 23 AC Output Mode Single Unit Operation 23 AC Output Mode Parallel in Single Phase 23 AC Output Mode Three phase 3P1 3P...

Страница 25: ...diately Disabled Default 48 Equalization Activated Immediately Enable 49 Utility charging time 50 AC output time LCD Display Setting The LCD display information will be switched in turns by pressing U...

Страница 26: ...irmware Version of Inverter PCB and MPPT PCB CPU1 040 00 b21 CPU2 041 00 b21 Time 15 20 10 December 15 2018 The LCD will display different inverter status when the up or down button is pressed The las...

Страница 27: ...energy Charging by utility Charging by PV energy No charging Fault mode Note Fault mode Errors are caused by inside circuit error or external reasons such as over temperature output short circuited a...

Страница 28: ...ies model there are two DC fans The DC fans will just the fan speed in a linear proportion according to load and charger wattage It will slow down after 1 minute when the triggering condition disappea...

Страница 29: ...in comparison to DC coupled systems in that PV power is converted directly from DC to AC instead of DC to DC to AC When it works with grid tie inverters to form an AC coupling off grid system It can...

Страница 30: ...BP doesn t have this feature it is optional for volume order at the time of production 2 4 15 Lithium Battery Wakeup Lithium ion battery will enter sleep mode when it is overdischarged When the protec...

Страница 31: ...nts before selecting where to install Do not mount the inverter on flammable construction materials Mount on a solid surface Install this inverter at eye level in order to allow the LCD display to be...

Страница 32: ...specification of AC input with single phase Model 2 units 3 units 4 units 5 units 6 units M3048BP 100A 120VAC 150A 120VAC 200A 120VAC 250A 120VAC 300A 120VAC M5000H 48BP 100A 230VAC 150A 230VAC 200A...

Страница 33: ...rformed with care due to high battery voltage in series CAUTION Do not place anything between the flat part of the inverter terminal and the ring terminal Otherwise overheating may occur CAUTION Do no...

Страница 34: ...e follow below steps to implement PV module connection 1 Remove insulation sleeve 10 mm for positive and negative conductors 2 Check correct polarity of connection cable from PV modules and PV input c...

Страница 35: ...as air conditioner are required at least 2 3 minutes to restart because it s required to have enough time to balance refrigerant gas inside of circuits If a power shortage occurs and recovers in a sho...

Страница 36: ...tly screwed to the battery terminals Connect the end of RJ45 of battery to BMS communication port of inverter The other end of RJ45 insert to battery communication port Note if you choose lithium batt...

Страница 37: ...c or create 230 400Vac three phase The M3048BP can be stacked up to 6 pcs to expand output power in 120Vac or create 120 208Vac three phase When they are stacked all the inverters will share the loads...

Страница 38: ...m 23 Commissioning Parallel in single phase Step 1 Check the following requirements before commissioning Correct wire connection Ensure all breakers in Line wires of load side are open and each Neutra...

Страница 39: ...wires of load side are open and each Neutral wires of each unit are connected together Step 2 Turn on all units and configure LCD program 23 as 3P1 3P2 and 3P3 sequentially Then shut down all units No...

Страница 40: ...ach Neutral wires of each unit are connected together Step 2 Turn on all units and configure LCD program 23 as 2P0 on phase1 units then set as 2P2 or 2P1 on phase2 units 2P0 2P1 split phase 120V 208V...

Страница 41: ...peration exists Power interruption may happen to critical devices which cannot bear transfer time 3 8 Communication with Computer The inverter can be monitored on the computer Please use the communica...

Страница 42: ...Fault Code Fault Event Icon on 01 Fan is locked 02 Over temperature 03 Battery voltage is too high 04 Battery voltage is too low 05 Output short circuited 06 Output voltage is too high 07 Overload tim...

Страница 43: ...13 Solar charger stops due to high PV voltage Beep once every second 14 Solar charger stops due to overload Beep once every second 15 Parallel input utility grid different Beep once every second 16 P...

Страница 44: ...place battery No response after power on No indication 1 The battery voltage is far too low 1 4V Cell 2 Battery polarity is connected reversed 1 Check if batteries and the wiring are connected well 2...

Страница 45: ...repair center Warning code 15 The input status is different in parallel system Check if AC input wires of all inverters are connected well Warning code 16 Input phase is not correct Change the input p...

Страница 46: ...receipt of shipment Claims not reported within this time frame will not be honored This warranty does not apply to and we will not be responsible for any defect in or damage to a the product if it has...

Страница 47: ...off Voltage Lead Acid Mode 42 0Vdc load 20 40 8Vdc 20 load 50 38 4Vdc load 50 Low DC Cut off Voltage Li Mode 42 0Vdc Low DC Warning SOC Li Mode Low DC Cut off SOC 5 Low DC Warning Return SOC Li Mode L...

Страница 48: ...40 to 140 Altitude 2000m Cold start voltage is the minimal battery voltage for the inverter to power on without PV or AC input Errors and omissions reserved Specifications in this manual are subject t...