![Sigineer Power MS6048D Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/sigineer-power/ms6048d/ms6048d_user-manual_1267390042.webp)
www.sigineer.com
40
4 Maintenance & Troubleshooting
This troubleshooting guide contains information about how to troubleshoot possible error conditions while
using the M3048BP and M5000H-48BP Solar Power Inverter/Chargers.
The following chart is designed to help you quickly pinpoint the most common inverter failures.
Indicator and Buzzer
Fault Code
Fault Event
Icon on
01
Fan is locked
02
Over temperature
03
Battery voltage is too high
04
Battery voltage is too low
05
Output short circuited
06
Output voltage is too high.
07
Overload time out
08
Bus voltage is too high
09
Bus soft start failed
51
Over current or surge
52
Bus voltage is too low
53
Inverter soft start failed
55
Over DC voltage in AC output
56
Battery connection is open
57
Current sensor failed
58
Output voltage is too low
60
Negative power fault
61
PV voltage is too high
62
Internal communication error
Содержание MS6048D
Страница 6: ...www sigineer com 4...