Rev 3.2 Oct.05
67
+CGEQMIN (continued) Set or Query Minimum Quality of Service Profile (continued)
<Guaranteed bitrate DL>
is a number specifying the guaranteed speed (kbps)
of downlink traffic delivered by an SAP (Service Access Point). When this
parameter is set to “0”, the modem requests the subscribed value.
<Delivery order>
is a number specifying whether in-sequence SDU (Small
Downloadable Unit) delivery is to be provided by the UMTS bearer, where
0
=
no,
1
= yes, and
2
= subscribed value.
<Maximum SDU size>
is the maximum allowed SDU size, in octets.
<SDU error ratio>
is a string specifying a target ratio for SDUs that are lost or in
which errors are detected. (The target applies only to conforming traffic.) This
should be entered in the form “mEe”. For example, the value “5
·
10
-3
” should be
entered as “5E3”. When this parameter is set to “0E0”, the modem requests the
subscribed value.
<Residual bit error ratio>
is a string specifying a target for the undetected bit
error ratio in delivered SDUs. This parameter sets the bit error ratio in delivered
SDUs if no error detection is requested. This should be entered in the form
“mEe”. For example, the value “5
·
10
-3
” should be entered as “5E3”. When this
parameter is set to “0E0”, the modem requests the subscribed value.
<Delivery of erroneous SDUs>
is a number that indicates whether SDUs with
detected errors are to be delivered, where
0
= no,
1
= yes,
2
= no detect, and
3
= subscribed values.
<transfer delay>
is a number specifying the target duration, in milliseconds,
between a request to transfer an SDU at one SAP and delivery of the SDU at
the other SAP. When this parameter is set to “0”, the modem requests the
subscribed value.
<traffic handling priority>
is a number specifying the importance of SDUs
belonging to the UMTS bearer relative to SDUs belonging to other bearers.
When this parameter is set to “0”, the modem requests the subscribed value.
+CGEQMIN?
returns the current settings for each defined context, in the same
order as specified for the set command, while
+CGEQMIN=?
returns values
supported as a compound value. The parameter value ranges for each PDP
type are returned on a separate line.
Table 3-9: Command Reference Table (ASCII Alphabetic)
Command
Description
Содержание MP 700 Series
Страница 1: ...MP 700 Series GPS Rugged Wireless Modem AT Command Reference 2130309 Rev 3 2...
Страница 2: ......
Страница 6: ...MP 700 Series GPS AT Command Reference 4 2130309...
Страница 24: ...MP 700 Series GPS AT Command Reference 22 2130309...
Страница 116: ...Index Rev 3 2 Oct 05 114...
Страница 117: ......
Страница 118: ......