Rev 3.2 Oct.05
33
!MPAINCFG=
<chan>,
"
<input
label>
"
,
"
<unit
label>
"
,<zero
scale>,<full scale>
!MPAINCFG?=
<chan>
Analog input channel configuration
Sets the labels and the scale for the specified input channel.
Parameter settings
The supported values are:
•
Channel
<chan>=
1
Analog input 1
2
Analog input 2
3
Analog input 3
4
Analog input 4
•
Sensor or gauge description
<input label>=
20 character string
•
Name of units
<unit label>=
20 character string
•
Minimum value
<zero scale>=
0 to 65535 (Must be less than <full scale>)
•
Maximum value
<full scale>=
0 to 65535 (Must be greater than <zero scale>)
!MPAINCFG?
returns the configuration parameter values for the specified
channel.
!MPAUTHPPP=<n>
!MPAUTHPPP?
Enable / disable PPP authentication between the modem and the host PC
This command is only available on modems with firmware version 2.0 or
greater.
Controls whether PPP authentication is used in the modem-to-host PC link.
(This command has no effect on the link between the MP and the embedded
AirCard, over which PPP authentication is always used.)
The
<n>
parameter has these settings:
•
<n>=1
Enables PPP authentication
•
<n>=0
Disables PPP authentication between the modem and the host PC
(default)
Disabling PPP authentication allows you to use a single dial-up PPP connection
on multiple modems with different GPRS profiles.
!MPAUTHPPP?
returns the current setting.
Table 3-9: Command Reference Table (ASCII Alphabetic)
Command
Description
Содержание MP 700 Series
Страница 1: ...MP 700 Series GPS Rugged Wireless Modem AT Command Reference 2130309 Rev 3 2...
Страница 2: ......
Страница 6: ...MP 700 Series GPS AT Command Reference 4 2130309...
Страница 24: ...MP 700 Series GPS AT Command Reference 22 2130309...
Страница 116: ...Index Rev 3 2 Oct 05 114...
Страница 117: ......
Страница 118: ......