background image

12

The EASYFIRE will automatically switch to 12 volt backup

provided you have the 12 volt option installed.

deactivate the timer you will have to start over by turning the
knob to off and then back to FAN or LOW.

2. P ro ble m :

  The heater was lit and burning properly, then

suddenly it stopped feeding pellets.

Solution:

 a) C heck  pellet supply in hopper. If em pty, fill

and follow start-up procedure as outlined in the beginning
of this m anual.  b) O cc asionally, a foreign obje ct, debris
or an excessive amount of sawdust can enter the feed
mechanism and jam  the feed chute. If this happens, you
must em pty the hopper and check the feed chute to see
what is causing the jam. Rem ove any foreign material or
obje ct and re-start the he ater. 

CAUTION:

 Keep fingers

and hands clear of feed mechanism when heater is on.

3. P ro ble m :

  The fire w as b urning we ll and the n it beg an to

overfeed pellets and started backing up into the pellet
feed chute, smothering the fire.

Solution:

  W hen the pellets a re overfeeding, it us ually

m eans that the air flow has been red uced. Ch eck the F ire
Pot air intak e ho les to b e su re the y are clear. C hec k to
see  if Fire Pot wa s pro perly se ated  in pot tray. Che ck  to
see if the manifold may have filled with Fly-ash. If you
use  a low g rade  pellet, an d clink ers (fused a sh a nd d irt)
form  in the botto m  of the Fire Pot, it will choke  the air
intak e (you m ight co nsider ch ang ing the  bran d of p ellets
to one that burns cleaner).  You must let the fire go out
before rem oving  and  clean ing the  Fire P ot.

Ne ver vacuum  ou t the  hea ter w hen th e he ater is in
operation! The hot ashes can lodge in your vacuum
cleaner and cause a fire!

You must clean the manifold regularly in order to insure a

good air to fuel ratio, thus allowing the heater to "breathe"
properly. You must also check the vent pipe and tee to see
that they are not clogged and full of ash.

4. P ro ble m :

  Heater was burning well and then soot began

form ing on the glass door.

Solution:

  Black soot forming on the glass door means

that the combustion is not right and the heater needs a
good clean out.  Some brands of pellets burn much richer
than others and you might have to change brands of
pellets and/or have the air/fuel settings re-adjusted by
your dealer.  It is normal to have the glass cloud up after
several hours of burning but it should wipe off with a
good window c leaner. If the glass  turns black  quick ly,
then  the heate r nee ds a  goo d clea n ou t.

5. P ro ble m :

  W e had a power failure and the heater

emitted smok e for about five minutes.

Solution:

  If the heater emits smoke during a power

failure, and you have frequent power failures then we
suggest you purchase the battery back-up system. If the

vent pipe is installed according to these instructions the
smok e will syphon out of the pipe in most instances.

6. P ro ble m :

  After several week s of outstanding perfor-

mance, the heater suddenly stopped and the red light
under the control knob came on. This light is the Hi
Te m p/Flue Indicator Light.

Solution:

  The Hi-Temp/Flue Indicator light indicates that

Fly-ash has built up in the exhaust s yste m  and/o r there is
a restriction in the exhaust/flue system. Check the pipe
system for excessive ash and clogging, particularly the
vent cap.  Remove the clean out cap on the tee and
make sure that ash has not blocked the exhaust air flow.
This automatic shut down in case of flue clogging is a
safety feature and if the shut down occurs it means you
have a problem and should consult a service technician
and/or clean your pipe and heater thoroughly. If you feel
the Fly-ash build up is excessive, we sugg est that you try
another brand. In moist climates the pellets and Fly-ash
can  actually abso rb m oisture from  the air and crea te
creosote and a severe clogging problem . Ke ep this in
mind when you store and handle your pellets. The heater
warranty does not cover the quality of the fuels used or
the way they may be han dled either before or after you've
purchased them.

7. P ro ble m :

  I turned off the switch and the heater kept

running.

Solution:

  This is normal. The exhaust blower will keep

running until it cools down  and then it will auto m atic ally
turn off.  This can vary by the temperature the exhaust
has reac hed and  the temp erature of the cooling air.

HI TEMP/FLUE AND TRIM INDICATORS:

W hen  the H i-Tem p/Flue indicator light com es o n (red lite

beneath control knob) it means that the flue is obstructed or
you have a re verse draft and gases cannot ex it properly.
Maintenance is required and a thorough cleaning and pipe
check m ust be performed.

TRIM button :

  Underneath the control knob you will find a

sm all ro und butto n that w ill turn fo rward and rev erse.  This
button  can control the fee d m oto r in th e LOW  positio n only.
By turning the button clockwise you can increase the feed
on LOW  and by turning it counterclockwise you can
decrease the feed in the LOW  position.

M ove  this button  carefully!

  It is designed to fine tune

your LOW  setting  in the event you ch ang e bra nds  of pe llets
and/or live at a higher elevation.

All manuals and user guides at all-guides.com

Содержание EF-4001B AutoLite

Страница 1: ...ent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartm ents burn pot and circulat ing air passageways of the heater...

Страница 2: ...TSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTION...

Страница 3: ...continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and co...

Страница 4: ...t wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet rock or paneling is don...

Страница 5: ...or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or other component penetra...

Страница 6: ...Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your...

Страница 7: ...ay cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIR...

Страница 8: ...ir flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may have filled with Fly as...

Страница 9: ...ed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open the top lid and fill the...

Страница 10: ...ically adjusting the feed and air based on temperature This means the pellet feed rate and flam e height will change accordingly based on quality of pellet and heat loss of dwelling MAINTENANCE PROCED...

Страница 11: ...ishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use Windex or comparable product and a soft clean cloth to wipe any marks off a...

Страница 12: ...Problem We had a power failure and the heater emitted smoke for about five minutes Solution If the heater emits smoke during a power failure and you have frequent power failures then we suggest you p...

Страница 13: ...FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR R...