Figure 14
Note: Caution must be taken when installing burn pot
or operating door not to damage ceramic glass. Do not
attempt to op erate he ater if glas s be comes d am aged in
any w ay!
2. Control Functions:
Control functions on the Eas yfire
are as follows: OFF, FAN, LOW , MEDIUM, HIGH, CLEAN.
Here is how each function works:
A.
W hen the Control is set to
FAN
, a timer is activated
and you will have about ten (10) minutes to get the
pellets lit and rea ch a m inim um tem pera ture.
Should the pellets not light in the 10 m inutes simp ly turn
the knob to
OFF
and begin again. This will give you
another 10 minutes to get the pellets lit. The reason for
the tim er fun ctio n is so that the heate r will autom atic ally
shut down if the fire goes out. Pellets do not feed in the
FAN position.
B.
In the
LOW
position, the EASYFIRE will be feeding
approximately 1 to 1½ lbs. of pellets per hour and the
flam e will fluctuate betwe en 1 " and 6" in height.
C.
In the
MEDIUM
position the EASYFIRE will be
feeding approximately three (3) pounds of pellets per
hour and the flame will fluctuate between 3" and 8" of
fire.
D.
In the
HIGH
position the EASYFIRE will be feeding
approxim ate ly 4 lbs. p er hour and the fla m e will
fluctuate between 3" and a full flame. The fan speed
will increase accordingly as the heate r au tom atic ally
adjusts itself based on temperature inside the heater
(see G below).
E.
The
CL EAN
position is to be used only when the
heater is not burning and you wish to clean out the
accumulated ash in the front of the fire area. See
CLEAN OUT
section of maintenance instructions.
F.
After the heater is running for several hours and you
wish to turn it off simply turn the knob to
OFF
.
The
heater will continue running until it cools down
and then will automatically shut itself down
.
G.
REMEMBER:
Eac h fee d po sition will fluctu ate
because the m icroprocess or is auto m atic ally
adjus ting the fee d and air b ased on tem perature. T his
m eans the pellet feed ra te and flam e height w ill
change accordingly based on quality of pellet and
heat loss of dwelling.
MAINTENANCE PROCEDURE
CAUTION:
Moving parts may cause injury, DO NOT
operate with rear cover removed.
WARNING:
Risk of electrical shock, disconnect all power
before servicing.
ALWAYS TURN YOUR Heater OFF & LET IT COOL
BEFORE CLEANING.
Your EASYFIRE Pellet Heater requires routine
m aintenance for m axim um perform ance an d is ma ndatory
for the warranty to re m ain in effec t.
The following procedures should be studied carefully and
performed regularly as indicated:
1. Fly-ash:
Some ash will accumulate in the heat
exchanger, Fire Pot and flue and should be cleaned out
on a regu lar basis for bes t efficien cy and sa fety. W hen
the heater is shut down and cold, you should:
a.
Open door and remove Heat Exchanger Cover. To
rem ove, s im ply slide up and out from retaining angle
brac ket (
Figure 12
). Clea n on e side at a tim e. W ith
one slide cover rem oved,
leave door open
and turn
control knob to the
"CLEAN"
position. Let heater run
until ash in Fire Pot area is vacuumed out by heater
fan. Turn off and replace cover. Rem ove remaining
cover and repeat procedure for the other side. The
vent pipe should be cleaned out after this procedure.
Rem ove the clean-out port cover
(Figure 13)
and
vacuum as re quired.
b.
Rem ove Fire Pot by lifting up and out, it may be
brushed out or vacuumed. Fire Pot should be
cleaned daily. Make sure holes in pot are not
clogged. The are a around and below the pot sh ould
be checked every five or six days depending on how
many hours a day you are burning your heater and
the quality of the pellets being burned. (After a few
days you will be able to determine the frequency
nee ded for clean out.)
The im portant th ing to rem em ber is that ex cess ive Fly-
ash accumulation will affect the efficiency of the burn.
c.
Scrape pellet feed chu te with putty knife to rem ove
hardened material on which sawdust can
accumulate.