Figure 14

Note: Caution must be taken when installing burn pot
or operating door not to damage ceramic glass. Do not
attempt to  op erate he ater if glas s be comes d am aged in
any w ay!

2. Control Functions:

  Control functions on the Eas yfire

are as follows:  OFF, FAN, LOW , MEDIUM, HIGH, CLEAN.
Here is how each function works:

A.

W hen the Control is set to 

FAN

, a timer is activated

and you will have about ten (10) minutes to get the
pellets lit and rea ch a  m inim um  tem pera ture.  

Should the pellets not light in the 10 m inutes simp ly turn
the knob to 

OFF

 and begin again.  This will give you

another 10 minutes to get the pellets lit.  The reason for
the  tim er fun ctio n is so that the  heate r will autom atic ally
shut down if the fire goes out.  Pellets do not feed in the
FAN position.

B.

In the 

LOW

 position, the EASYFIRE will be feeding

approximately 1 to 1½ lbs. of pellets per hour and the
flam e will fluctuate betwe en 1 " and 6" in height.

C.

In the 

MEDIUM

 position the EASYFIRE will be

feeding approximately three (3) pounds of pellets per
hour and the flame will fluctuate between 3" and 8" of
fire.

D.

In the 

HIGH

 position the EASYFIRE will be feeding

approxim ate ly 4 lbs. p er hour and the fla m e will
fluctuate between 3" and a full flame.  The fan speed
will increase accordingly as the heate r au tom atic ally
adjusts itself based on temperature inside the heater
(see G  below).

E.

The 

CL EAN

 position is to be used only when the

heater is not burning and you wish to clean out the
accumulated ash in the front of the fire area. See

CLEAN OUT

 section of maintenance instructions.

F.

After the heater is running for several hours and you
wish to turn it off simply turn the knob to 

OFF

The

heater will continue running until it cools down
and then will automatically shut itself down

.

G.

REMEMBER:

  Eac h fee d po sition will fluctu ate

because the m icroprocess or is auto m atic ally
adjus ting  the fee d and air b ased on tem perature. T his
m eans the pellet feed ra te and flam e height w ill
change accordingly based on quality of pellet and
heat loss of dwelling.

MAINTENANCE PROCEDURE

CAUTION:

  Moving parts may cause injury, DO NOT

operate with rear cover removed.

WARNING:

  Risk of electrical shock, disconnect all power

before servicing.

ALWAYS TURN YOUR Heater OFF & LET IT COOL
BEFORE CLEANING.

Your EASYFIRE Pellet Heater requires routine

m aintenance for m axim um  perform ance an d is ma ndatory
for the  warranty to re m ain in effec t.

The following procedures should be studied carefully and

performed regularly as indicated:

1. Fly-ash:

  Some ash will accumulate in the heat

exchanger, Fire Pot and flue and should be cleaned out
on a  regu lar basis for bes t efficien cy and sa fety.  W hen
the heater is shut down and cold, you should:

a.

Open door and remove Heat Exchanger Cover. To
rem ove, s im ply slide up and out from  retaining angle
brac ket (

Figure 12

). Clea n on e side  at a tim e. W ith

one  slide cover rem oved, 

leave door open 

and turn

control knob to the 

"CLEAN"

 position. Let heater run

until ash in Fire Pot area is vacuumed out by heater
fan. Turn off and replace cover. Rem ove remaining
cover and repeat procedure for the other side.  The
vent pipe should be cleaned out after this procedure.
Rem ove the clean-out port cover 

(Figure 13)

 and

vacuum  as re quired. 

b.

Rem ove Fire Pot by lifting up and out, it may be
brushed out or vacuumed. Fire Pot should be
cleaned daily. Make sure holes in pot are not
clogged.  The are a around and below  the pot sh ould
be checked every five or six days depending on how
many hours a day you are burning your heater and
the quality of the pellets being burned.  (After a few
days you will be able to determine the frequency
nee ded  for clean out.)

The im portant th ing to rem em ber is that ex cess ive Fly-

ash accumulation will affect the efficiency of the burn.

c.

Scrape  pellet feed chu te with putty knife to rem ove
hardened material on which sawdust can
accumulate.

All manuals and user guides at all-guides.com

Содержание EF-4001B AutoLite

Страница 1: ...ent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartm ents burn pot and circulat ing air passageways of the heater...

Страница 2: ...TSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTION...

Страница 3: ...continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and co...

Страница 4: ...t wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet rock or paneling is don...

Страница 5: ...or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or other component penetra...

Страница 6: ...Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your...

Страница 7: ...ay cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIR...

Страница 8: ...ir flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may have filled with Fly as...

Страница 9: ...ed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open the top lid and fill the...

Страница 10: ...ically adjusting the feed and air based on temperature This means the pellet feed rate and flam e height will change accordingly based on quality of pellet and heat loss of dwelling MAINTENANCE PROCED...

Страница 11: ...ishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use Windex or comparable product and a soft clean cloth to wipe any marks off a...

Страница 12: ...Problem We had a power failure and the heater emitted smoke for about five minutes Solution If the heater emits smoke during a power failure and you have frequent power failures then we suggest you p...

Страница 13: ...FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR R...

Отзывы: