2
EF4100 Overall Dimensions
Figure 2
Provide ade qua te clearances around air openings into the
combustion chamber and adequate accessibility clearance for
servicing and prope r operation. Never obstruct the front
opening of the hea ter.
The heater may be installed as a free-stan ding unit m oun t-
ed on a noncombustible protective floor pad or he arth, o r it
may be m oun ted into an existing U. L. approved wood stove
chimney using a Hearth Extension (p/n 11099). Non-combu-
stib le floor protection is required and must be used when
placing the heater on any com bustib le m ate rial.
The pellet heater m ust b e operated with a power source
and will not operate using natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, th e heater will auto m atic ally switc h to 12 volt
power. An
optional
backup battery is available for the unit
which lasts approximately 48 hrs on high and 72 hrs on low.
A bigger battery may be purch ased if desired for longer
durations.
The EasyFire Pellet Heater has been listed by OM NI-Test
Laboratories, Inc. to ASTM, U.L.,and EPA Standards.
CAUTION:
Do not connect this unit to a chimney flue serving
another appliance.
Use only listed Type "L" pellet vent or stainless liner and
com pon ents for installation. Failure to use listed com pon ents
will void your warranty. See pipe manufacturer instructions for
installation instructions.
OU TS IDE CO M BU ST ION AIR IS M AND ATO RY IN
MO BILE OR MO DULAR HOM E INSTALLATIONS.
SEE
SECTION ON OUTSIDE AIR INSTALLATION.
C A U T IO N : D O N O T C O N NE C T TO AN Y AI R
DISTRIBUTION DUCT O R SYSTEM .
INSTALLATION INSTRUCTIONS
Check with local building officials for specific code
requirements.
A listed , type "L" Pellet V ent Pip e or Stain less Liner is
MANDATORY on all installations.
WARNING:
In sta lla tio n o f a M ob ile Atta ch m en t H om e
Kit P/N 1041 2 and ou tside c om bustion air is ma ndatory
in mobile or modular home installations
although it may
also be used in all reside ntial application s.
An outs ide air inlet MU ST be provided for
com bustion and ven tilation air.
The air inlet must
rem ain unrestricte d while unit is in use. O uts ide air
conne ction is located in the rear of the heater (
Figure 1
).
NOTE:
Vent Pipes’ inner diameters may vary.
For Vent Pipes Ø3.00" or smaller, use SPI Exhaust Vent
Adapter p/n 11076.
This adapter is used on Selkirk Metalbestos™ and other
Ø2.950" I.D. Pellet Vent Pipes.
Use conduit pipe or metal flex pipe and/or fittings to make
the air intake hook-up.
Also, the
struc tural inte grity of th e m obile hom e floo r,
walls and ceiling/roof must be maintained
.
1.
Clean and inspect the fireplace and its chim ney for any
structural defect that may cause any future problems.
Secure gas piping that is installed with a cap and verify
there are no leaks. Seal ash dump or an y other acc ess to
the firebox area. Fix the damper in an open position or
remove it as required for vent pipe installation.
2.
Verify the req uired hea rth an d side and clearanc es to
mantels
(fig. 2 & 3)
.