background image

ITEM No.

PART NUMBER

DESCRIPTION

1

110429

DOOR FRONT GLASS (Ceramic glass 11"x11 3/4"x5mm)

2

100119

GLASS FIBER GASKET

3

100125

DOOR FIBER ROPE GASKET

4

300536

FEED AUGER SYSTEM V3

5

300106

COMBUSTION BLOWER ASSEMBLY

6

120114

CONTROL BOARD V2.1

6A

110080

MAIN FUSE - 1 AMP

6B

110510

AUTOLITE FUSE - 5 AMP

7

200549

HEAT EXCHANGE COVER

8

110456

ASH DRAWER FIBER ROPE GASKET

9

110451

ASH DRAWER KNOB

10

120117

IGNITOR-200W

11

300512

BURN POT AL V2

12

120120

IGNITOR RELAY

13

120118

PUSH BUTTON SWITCH V2.1

14

110058

HANDLE ASSEMBLY

15

10407

SURROUND ASSEMBLY

5061 Brooks St. Montclair, CA 91763

Phone 1-909-399-3355 Fax 1-909-399-3357

www.empireproductsinc.com

P/N 140706r3 03/08

All manuals and user guides at all-guides.com

Содержание EF-4001B AutoLite

Страница 1: ...ent cleaning may be required due to fuel quality excessive lint from carpeting bedding material etc It is imperative that control compartm ents burn pot and circulat ing air passageways of the heater...

Страница 2: ...TSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS SEE SECTION ON OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTION...

Страница 3: ...continuing to the top of the chimney If the total vent length is longer than 10 Feet install 4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and co...

Страница 4: ...t wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of course run wire in the walls before sheet rock or paneling is don...

Страница 5: ...or partition of combustible construction is desired the installation shall conform the CAN CSA B365 3 Maintain an effective vapour barrier at the location where the chimney or other component penetra...

Страница 6: ...Store pellets in a clean dry area Do not use pellets that have been damp or have a moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your...

Страница 7: ...ay cause injury DO NOT operate with rear cover removed WARNING Risk of electrical shock disconnect all AC DC power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIR...

Страница 8: ...ir flow has been reduced Check the Fire Pot air intake holes to be sure they are clear Check to see if Fire Pot was properly seated in pot tray Check to see if the manifold may have filled with Fly as...

Страница 9: ...ed before operating unit Maintain hopper seal in good condition DO NOT OVERFILL HOPPER The EASYFIRE will hold about 35 lbs to 50 lbs of pellets depending on hopper height Open the top lid and fill the...

Страница 10: ...ically adjusting the feed and air based on temperature This means the pellet feed rate and flam e height will change accordingly based on quality of pellet and heat loss of dwelling MAINTENANCE PROCED...

Страница 11: ...ishing Gold Plated Parts Gold is a soft metal and therefore a fragile surface Prior to the first burn it is important to use Windex or comparable product and a soft clean cloth to wipe any marks off a...

Страница 12: ...Problem We had a power failure and the heater emitted smoke for about five minutes Solution If the heater emits smoke during a power failure and you have frequent power failures then we suggest you p...

Страница 13: ...FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR R...

Отзывы: