![Siemens SITRANS LG240 Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/siemens/sitrans-lg240/sitrans-lg240_operating-instructions-manual_374496075.webp)
75
PBD-51041038
SITRANS LG240 - Operating Instructions
44286-EN-171021
Shock resistance
Ʋ Rod probe
25 g, 6 ms according to EN 60068-2-27 (mechanical
shock) with rod length 50 cm (19.69 in)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable entry
Ʋ M20 x 1.5
1 x cable gland M20 x 1.5 (cable: ø 6 … 12 mm), 1 x
blind plug M20 x 1.5
Ʋ ½ NPT
1 x blind plug NPT, 1 x closing cap (red) ½ NPT
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Display and adjustment module
Display element
Display with backlight
Measured value indication
Ʋ Number of digits
5
Ʋ Size of digits
W x H = 7 x 13 mm
Adjustment elements
Ʋ 4 keys
[OK]
,
[->]
,
[+]
,
[ESC]
Ʋ Switch
Bluetooth On/Off
Protection rating
Ʋ unassembled
IP 20
Ʋ mounted in the housing without lid
IP 40
Materials
Ʋ Housing
ABS
Ʋ Inspection window
Polyester foil
Functional safety
SIL non-reactive
Integrated clock
Date format
Day.Month.Year
Time format
12 h/24 h
Time zone, factory setting
CET
Max. rate deviation
10.5 min/year
Additional output parameter - Electronics temperature
Output of the values
Ʋ Indication
Via the display and adjustment module
Ʋ Analogue
Via the current output
Ʋ Digital
Via the digital output signal (depending on the electron-
ics version)
Range
-40 … +85 °C (-40 … +185 °F)
Содержание SITRANS LG240
Страница 2: ...2 PBD 51041038 SITRANS LG240 Operating Instructions 44286 EN 171021 ...
Страница 85: ...Notes 85 PBD 51041038 SITRANS LG240 Operating Instructions 44286 EN 171021 ...
Страница 86: ...Notes 86 PBD 51041038 SITRANS LG240 Operating Instructions 44286 EN 171021 ...
Страница 87: ...Notes 87 PBD 51041038 SITRANS LG240 Operating Instructions 44286 EN 171021 ...