E-2
1010FMA-45
Errata
2.2.2 POWER SUPPLY WIRING
l
Using a 1/16" Hex key, loosen the 1010X Rear Housing Cover locking setscrew.
l
Unscrew the Rear Housing Cover and remove.
IMPORTANT: Power Supply label is located inside the Rear Housing cover.
l
Locate power supply connector J8. Use the tables below and the part number of your unit to
determine the correct input power source. (See also metal ID label on unit housing.)
l
Pull wires through flowmeter case conduit cable hole.
l
Wire input power connector P8 for AC or DC power as shown below. Insert wires into wire
entry holes and secure by tightening wire clamp screws (see note on next page).
Terminal
1010X-6SS2 1010X-6ZNS2 1010X-6ZPS2
1010X-6Z
Number
1
Hot
Positive
Positive (Gnd)
Positive
2
Neutral
Negative (Gnd)
Negative
Negative
3
Ground
Ground
Ground
Ground
Input Power Connector (P8) Wiring
NOTE: Loosen Wire
Clamp Screw, insert
stripped end of wire
and then retighten.
GND
GND
3
2
1
HOT
+
DC
AC
P8
NEU
-
2
3
1
Connector
Mounting
Screws
Stripped Wire
Wire
Clamp
Screws
NOTE: Power Supply connector wires should be stripped stranded or solid conductors
AWG 12 -18.
Root Meter Number
Transducer Support
Relay Support
Numeric Display
Power Supply Option
1010X-T2KNZPL2-S2----Safety Rating Option
Language Option
*Typical 1010X Part Number Construction:
Meter Part Number *
Power Supply P/N
User Supplied Power
Contains S prior to S_Code
1010X-6SS2
90-230 VAC Single Phase
Contains a ZN prior to S_Code
1010X-6ZNS2
9-36 VDC Negative Ground
Contains a ZP prior to S_Code
1010X-6ZPS2
9-36 VDC Positive Ground
Contains a Z at end of P/N
1010X-6Z
9-36 VDC Floating
Содержание SITRANS FUH1010PVX
Страница 2: ......
Страница 6: ......
Страница 14: ......
Страница 28: ......
Страница 130: ......
Страница 186: ......
Страница 187: ...Siemens Hardware ...
Страница 188: ......
Страница 189: ...Siemens Hardware ...
Страница 190: ......
Страница 191: ...Siemens Hardware ...
Страница 192: ......
Страница 193: ...Siemens Hardware ...
Страница 194: ......
Страница 195: ...Siemens Hardware ...
Страница 196: ...1010N 5 7 INSTALLATION DRAWING ANALOG INPUT MODULE 21614 C ...
Страница 200: ...1011HNS 7 USE OF FLEXIBLE CONDUIT WITH TRANSDUCERS SIZE A B 21614 C USE OF FLEXIBLE CONDUIT WITH TRANSDUCERS SIZE C D ...
Страница 201: ...1011HNS 8 TRANSDUCER PART NUMBER L H W SIZE C D SIZE A B 21614 C Siemens Hardware ...
Страница 202: ......
Страница 203: ...Siemens Hardware ...
Страница 204: ......
Страница 206: ......
Страница 214: ......
Страница 225: ...Siemens Hardware ...