2-52
1010BXFM-3
Section 2
2.9.2 PATH SELECT
The [Path Select] menu cell allows the selection of individual path diagnostics. Selecting Path
[1] or Path [2] will display the entire Diagnostic List.
To select the Path Select function:
To access [Path Select] press
To select Path [1] or Path [2] press
To store the selection press
ENT
2.9.1 MAIN DIAGNOSTICS SCREEN
This is the Main Diagnostics Data screen. It provides menus that show Path Select, Path
Enable, Signal Data, Application Info, Liquid Data, Site Setup Data information. In addition,
the Test Facilities menu provides test/control functions to optimize operation, analyze appli-
cation conditions and to recover system operation. Also included are Print Site Setup and
Date Site Setup menus. As shown below, diagnostics provides nine menus and two menu cells:
Path Select
1 and 2
Path Enable
Controlotron
Dual Path
SITE 1
Select Diagonostics Data Display Source
Signal Data
Application Info
Liquid Data
Site Setup Data
Test Facililties
Print Site Setup
No
Date Site Created
08.11.99 11.99 12.48.58
I/O Data Control
Path Select
This meau allows selection of Path 1 or Path 2.
Path Enable
This menu enables the selected Path.
Signal Data
This menu shows Signal specific data.
Application Info
This menu shows current meter operating status.
Liquid Data
This menu shows current RTD temperature readings among others
(if this system includes optional RTD Temperature measurement cap-
ability).
Site Setup Data
This menu shows current transducer setup data and signal status.
Test Facilities
This menu provides system test and recovery routines.
Print Site Setup
This Menu cell allows you to send an ASCII dump of the current Site.
Data to a RS-232 port device (e.g., a printer or laptop computer).
Date Site Created This menu cell shows date and time when the current site was created.
DIAGNOSTIC MAIN MENU DESCRIPTION
Содержание SITRANS FUH1010PVX
Страница 2: ......
Страница 6: ......
Страница 14: ......
Страница 28: ......
Страница 130: ......
Страница 186: ......
Страница 187: ...Siemens Hardware ...
Страница 188: ......
Страница 189: ...Siemens Hardware ...
Страница 190: ......
Страница 191: ...Siemens Hardware ...
Страница 192: ......
Страница 193: ...Siemens Hardware ...
Страница 194: ......
Страница 195: ...Siemens Hardware ...
Страница 196: ...1010N 5 7 INSTALLATION DRAWING ANALOG INPUT MODULE 21614 C ...
Страница 200: ...1011HNS 7 USE OF FLEXIBLE CONDUIT WITH TRANSDUCERS SIZE A B 21614 C USE OF FLEXIBLE CONDUIT WITH TRANSDUCERS SIZE C D ...
Страница 201: ...1011HNS 8 TRANSDUCER PART NUMBER L H W SIZE C D SIZE A B 21614 C Siemens Hardware ...
Страница 202: ......
Страница 203: ...Siemens Hardware ...
Страница 204: ......
Страница 206: ......
Страница 214: ......
Страница 225: ...Siemens Hardware ...