• Device depth of the 3RW5 HMI Standard:
– Total depth: 32 mm
– Embedded depth: 29 mm
• Permissible wall thickness of the cabinet door:
– Without IP65 door mounting kit: 1.5 to 3.0 mm
– With IP65 door mounting kit: 1.0 to 7.0 mm
For using door mounting kit IP65:
• IP65 door mounting kit (accessory)
The fixing brackets with marking "001" are intended for a 3RW5 HMI Standard.
• Screwdriver PZ2
Procedure without door mounting kit IP65
s
s
[
Place the 3RW5 HMI Standard into the cutout of the control cabinet door
①
. Ensure that the
3RW5 HMI Standard engages audibly in 4 fixtures
②
.
Mounting and Dismantling
4.5 Installing / mounting / removing 3RW5 HMI
SIRIUS 3RW51 Soft Starter
42
Equipment Manual, 09/2020, A5E37108631002A/RS-AC/003
Содержание SIRIUS 3RW51
Страница 8: ...Table of contents SIRIUS 3RW51 Soft Starter 8 Equipment Manual 09 2020 A5E37108631002A RS AC 003 ...
Страница 32: ...Description 3 10 Accessories SIRIUS 3RW51 Soft Starter 32 Equipment Manual 09 2020 A5E37108631002A RS AC 003 ...
Страница 128: ...Functions 8 12 3RW5 HMI High Feature SIRIUS 3RW51 Soft Starter 128 Equipment Manual 09 2020 A5E37108631002A RS AC 003 ...
Страница 166: ...Circuit diagrams 13 1 CAx data SIRIUS 3RW51 Soft Starter 166 Equipment Manual 09 2020 A5E37108631002A RS AC 003 ...