System overview
1.5 System properties
SIRIUS Innovations
38
System Manual, 01/2011, A8E56203870002-03
1.5.11
Safety applications
SIRIUS switching devices are often used in parts of the system which have a bearing on
safety. The Safety Integrated concept enables uniform solutions to be created, from safety
relays through to fail-safe communication via AS-Interface or PROFIBUS DP.
Example
SIRIUS contactor in a safety application:
●
Motor starter protectors in combination with undervoltage release and contactor:
PL d (ISO 13849-1) or SIL 2 (IEC 62061)
●
Contactor assemblies for star-delta (wye-delta) start:
PL e (ISO 13849-1) or SIL 3 (IEC 62061)
1.5.12
Environmental protection
Siemens attaches great importance to the subject of eco-design. Our company-internal
standard SN 36350 on environmentally compatible product design has been permanently
integrated in our product development processes since 1993. Our production meets the
highest quality and environmental standards.
The CO
2
balance is another important topic as regards the manufacturing processes used
for our products. All Siemens products are eco-labeled in accordance with
DIN EN ISO 14021 as a matter of course. This process of eco-labeling makes our
environmentally-compatible product design more transparent and ensures that a continual
improvement in the CO
2
balance can be observed.
1.5.13
Energy efficiency
The devices which make up the SIRIUS modular system are designed for minimum power
loss, and passively and actively support the realization of efficient systems and applications.
Product example soft starters
●
Reduction of peak loads by up to 60%.
–
The soft starter protects the connected products and systems both on the connection
and drive sides.
●
Minimum intrinsic power loss thanks to integrated bypasses.
–
The complete soft starter portfolio bridges the thyristors during operation by means of
bypasses and thus enables the intrinsic power loss to be reduced to contactor level.
–
1 W power loss requires 3 W cooling expenditure. Typical frequency converters
generate a power loss which is 30 times higher than that created by a comparable soft
starter (bypass operation) and thus require 90 times the cooling expenditure.
●
The most space-saving starter ever.
–
Volume reduction compared to typical contactor assemblies for star-delta (wye-delta)
start: 66 %.
–
Volume reduction compared to typical frequency converters: up to 98%.
Содержание SIRIUS 3RH Series
Страница 1: ...SIRIUS Innovations System Manual 01 2011 Industrial Controls Answers for industry ...
Страница 2: ......
Страница 640: ...SIRIUS 3RA21 22 load feeders 6 12 Circuit diagrams SIRIUS Innovations 640 System Manual 01 2011 A8E56203870002 03 ...
Страница 760: ...Appendix A A 3 Correction sheet SIRIUS Innovations 760 System Manual 01 2011 A8E56203870002 03 ...
Страница 785: ......