![Siemens SIRIUS 3RH Series Скачать руководство пользователя страница 281](http://html.mh-extra.com/html/siemens/sirius-3rh-series/sirius-3rh-series_system-manual_383139281.webp)
SIRIUS 3RT2 contactors/contactor assemblies
2.8 Technical data
SIRIUS Innovations
System Manual, 01/2011, A8E56203870002-03
281
3RT2916-2BE01
3RT2916-2BK01
3RT2916-2BL01
Versions
OFF-delay device
Mechanical durability
Operating
cycles
30 million
Electrical durability, approx.
Operating
cycles
> 1 million
Switching frequency z max. (at T
u
=
60 °C)
h
-1
300
Power loss P
v
max. approx.
W
0.4
0.5
1
Surge suppression
With varistor, integrated
Conductor cross-sections
U
sp
= coil voltage
T
sp
= coil temperature
2)
1)
Doubling the delay time can be achieved by doubling the capacitance. Commercially available
capacitors which can be connected to terminals C+ and Z-
can be used.
2)
See the table titled "Conductor cross-sections - 3RT201. contactors".